Sound pressure level limits for stage machinery noise in operas and theaters
The absence of disturbing background noise is a fundamental minimum requirement for performances in opera houses and theaters. Although the acoustic design of such venues has reached some maturity and specifications for maximum allowable background levels can be found in almost every other textbook...
Ausführliche Beschreibung
The absence of disturbing background noise is a fundamental minimum requirement for performances in opera houses and theaters. Although the acoustic design of such venues has reached some maturity and specifications for maximum allowable background levels can be found in almost every other textbook on auditorium design, it can be observed that tender documents show a noteworthy variance in published requirements. Oftentimes, the levels that need to be achieved fall significantly below commonly quoted reference values. In order to keep the specifications at a reasonable level and to reduce costs for the (public) developer and builder it seems reasonable to review long-serving guidelines and determine if they suffice for today’s performance practice. Ausführliche Beschreibung