Initial rotor position estimation of SPMSM based on voltage vector injection method

Abstract In order to solve the starting failure problem of surface-mounted permanent magnet synchronous motor (SPMSM) at zero speed, it is necessary to estimate the initial position of rotor by using the magnetic saturation effect of motor. In this paper, a new method of voltage vector injection is...