Airway Management in Pediatric Patients: Cuff-Solved Problem?
Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of unc...
Ausführliche Beschreibung
Autor*in: |
Eva Klabusayová [verfasserIn] Jozef Klučka [verfasserIn] Milan Kratochvíl [verfasserIn] Tereza Musilová [verfasserIn] Václav Vafek [verfasserIn] Tamara Skříšovská [verfasserIn] Jana Djakow [verfasserIn] Martina Kosinová [verfasserIn] Pavla Havránková [verfasserIn] Petr Štourač [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2022 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
In: Children - MDPI AG, 2014, 9(2022), 10, p 1490 |
---|---|
Übergeordnetes Werk: |
volume:9 ; year:2022 ; number:10, p 1490 |
Links: |
---|
DOI / URN: |
10.3390/children9101490 |
---|
Katalog-ID: |
DOAJ020992939 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ020992939 | ||
003 | DE-627 | ||
005 | 20240414180813.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/children9101490 |2 doi | |
035 | |a (DE-627)DOAJ020992939 | ||
035 | |a (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
050 | 0 | |a RJ1-570 | |
100 | 0 | |a Eva Klabusayová |e verfasserin |4 aut | |
245 | 1 | 0 | |a Airway Management in Pediatric Patients: Cuff-Solved Problem? |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. | ||
650 | 4 | |a cuff | |
650 | 4 | |a airway management | |
650 | 4 | |a pediatric patient | |
650 | 4 | |a uncuffed tube | |
650 | 4 | |a cuffed tube | |
653 | 0 | |a Pediatrics | |
700 | 0 | |a Jozef Klučka |e verfasserin |4 aut | |
700 | 0 | |a Milan Kratochvíl |e verfasserin |4 aut | |
700 | 0 | |a Tereza Musilová |e verfasserin |4 aut | |
700 | 0 | |a Václav Vafek |e verfasserin |4 aut | |
700 | 0 | |a Tamara Skříšovská |e verfasserin |4 aut | |
700 | 0 | |a Jana Djakow |e verfasserin |4 aut | |
700 | 0 | |a Martina Kosinová |e verfasserin |4 aut | |
700 | 0 | |a Pavla Havránková |e verfasserin |4 aut | |
700 | 0 | |a Petr Štourač |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t Children |d MDPI AG, 2014 |g 9(2022), 10, p 1490 |w (DE-627)768093007 |w (DE-600)2732685-8 |x 22279067 |7 nnns |
773 | 1 | 8 | |g volume:9 |g year:2022 |g number:10, p 1490 |
856 | 4 | 0 | |u https://doi.org/10.3390/children9101490 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e |z kostenfrei |
856 | 4 | 0 | |u https://www.mdpi.com/2227-9067/9/10/1490 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2227-9067 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 9 |j 2022 |e 10, p 1490 |
author_variant |
e k ek j k jk m k mk t m tm v v vv t s ts j d jd m k mk p h ph p š pš |
---|---|
matchkey_str |
article:22279067:2022----::iwyaaeetneitiptetcf |
hierarchy_sort_str |
2022 |
callnumber-subject-code |
RJ |
publishDate |
2022 |
allfields |
10.3390/children9101490 doi (DE-627)DOAJ020992939 (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e DE-627 ger DE-627 rakwb eng RJ1-570 Eva Klabusayová verfasserin aut Airway Management in Pediatric Patients: Cuff-Solved Problem? 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. cuff airway management pediatric patient uncuffed tube cuffed tube Pediatrics Jozef Klučka verfasserin aut Milan Kratochvíl verfasserin aut Tereza Musilová verfasserin aut Václav Vafek verfasserin aut Tamara Skříšovská verfasserin aut Jana Djakow verfasserin aut Martina Kosinová verfasserin aut Pavla Havránková verfasserin aut Petr Štourač verfasserin aut In Children MDPI AG, 2014 9(2022), 10, p 1490 (DE-627)768093007 (DE-600)2732685-8 22279067 nnns volume:9 year:2022 number:10, p 1490 https://doi.org/10.3390/children9101490 kostenfrei https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e kostenfrei https://www.mdpi.com/2227-9067/9/10/1490 kostenfrei https://doaj.org/toc/2227-9067 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 10, p 1490 |
spelling |
10.3390/children9101490 doi (DE-627)DOAJ020992939 (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e DE-627 ger DE-627 rakwb eng RJ1-570 Eva Klabusayová verfasserin aut Airway Management in Pediatric Patients: Cuff-Solved Problem? 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. cuff airway management pediatric patient uncuffed tube cuffed tube Pediatrics Jozef Klučka verfasserin aut Milan Kratochvíl verfasserin aut Tereza Musilová verfasserin aut Václav Vafek verfasserin aut Tamara Skříšovská verfasserin aut Jana Djakow verfasserin aut Martina Kosinová verfasserin aut Pavla Havránková verfasserin aut Petr Štourač verfasserin aut In Children MDPI AG, 2014 9(2022), 10, p 1490 (DE-627)768093007 (DE-600)2732685-8 22279067 nnns volume:9 year:2022 number:10, p 1490 https://doi.org/10.3390/children9101490 kostenfrei https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e kostenfrei https://www.mdpi.com/2227-9067/9/10/1490 kostenfrei https://doaj.org/toc/2227-9067 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 10, p 1490 |
allfields_unstemmed |
10.3390/children9101490 doi (DE-627)DOAJ020992939 (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e DE-627 ger DE-627 rakwb eng RJ1-570 Eva Klabusayová verfasserin aut Airway Management in Pediatric Patients: Cuff-Solved Problem? 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. cuff airway management pediatric patient uncuffed tube cuffed tube Pediatrics Jozef Klučka verfasserin aut Milan Kratochvíl verfasserin aut Tereza Musilová verfasserin aut Václav Vafek verfasserin aut Tamara Skříšovská verfasserin aut Jana Djakow verfasserin aut Martina Kosinová verfasserin aut Pavla Havránková verfasserin aut Petr Štourač verfasserin aut In Children MDPI AG, 2014 9(2022), 10, p 1490 (DE-627)768093007 (DE-600)2732685-8 22279067 nnns volume:9 year:2022 number:10, p 1490 https://doi.org/10.3390/children9101490 kostenfrei https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e kostenfrei https://www.mdpi.com/2227-9067/9/10/1490 kostenfrei https://doaj.org/toc/2227-9067 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 10, p 1490 |
allfieldsGer |
10.3390/children9101490 doi (DE-627)DOAJ020992939 (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e DE-627 ger DE-627 rakwb eng RJ1-570 Eva Klabusayová verfasserin aut Airway Management in Pediatric Patients: Cuff-Solved Problem? 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. cuff airway management pediatric patient uncuffed tube cuffed tube Pediatrics Jozef Klučka verfasserin aut Milan Kratochvíl verfasserin aut Tereza Musilová verfasserin aut Václav Vafek verfasserin aut Tamara Skříšovská verfasserin aut Jana Djakow verfasserin aut Martina Kosinová verfasserin aut Pavla Havránková verfasserin aut Petr Štourač verfasserin aut In Children MDPI AG, 2014 9(2022), 10, p 1490 (DE-627)768093007 (DE-600)2732685-8 22279067 nnns volume:9 year:2022 number:10, p 1490 https://doi.org/10.3390/children9101490 kostenfrei https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e kostenfrei https://www.mdpi.com/2227-9067/9/10/1490 kostenfrei https://doaj.org/toc/2227-9067 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 10, p 1490 |
allfieldsSound |
10.3390/children9101490 doi (DE-627)DOAJ020992939 (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e DE-627 ger DE-627 rakwb eng RJ1-570 Eva Klabusayová verfasserin aut Airway Management in Pediatric Patients: Cuff-Solved Problem? 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. cuff airway management pediatric patient uncuffed tube cuffed tube Pediatrics Jozef Klučka verfasserin aut Milan Kratochvíl verfasserin aut Tereza Musilová verfasserin aut Václav Vafek verfasserin aut Tamara Skříšovská verfasserin aut Jana Djakow verfasserin aut Martina Kosinová verfasserin aut Pavla Havránková verfasserin aut Petr Štourač verfasserin aut In Children MDPI AG, 2014 9(2022), 10, p 1490 (DE-627)768093007 (DE-600)2732685-8 22279067 nnns volume:9 year:2022 number:10, p 1490 https://doi.org/10.3390/children9101490 kostenfrei https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e kostenfrei https://www.mdpi.com/2227-9067/9/10/1490 kostenfrei https://doaj.org/toc/2227-9067 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 10, p 1490 |
language |
English |
source |
In Children 9(2022), 10, p 1490 volume:9 year:2022 number:10, p 1490 |
sourceStr |
In Children 9(2022), 10, p 1490 volume:9 year:2022 number:10, p 1490 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
cuff airway management pediatric patient uncuffed tube cuffed tube Pediatrics |
isfreeaccess_bool |
true |
container_title |
Children |
authorswithroles_txt_mv |
Eva Klabusayová @@aut@@ Jozef Klučka @@aut@@ Milan Kratochvíl @@aut@@ Tereza Musilová @@aut@@ Václav Vafek @@aut@@ Tamara Skříšovská @@aut@@ Jana Djakow @@aut@@ Martina Kosinová @@aut@@ Pavla Havránková @@aut@@ Petr Štourač @@aut@@ |
publishDateDaySort_date |
2022-01-01T00:00:00Z |
hierarchy_top_id |
768093007 |
id |
DOAJ020992939 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ020992939</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20240414180813.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230226s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3390/children9101490</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ020992939</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RJ1-570</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Eva Klabusayová</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Airway Management in Pediatric Patients: Cuff-Solved Problem?</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">cuff</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">airway management</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">pediatric patient</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">uncuffed tube</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">cuffed tube</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Pediatrics</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Jozef Klučka</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Milan Kratochvíl</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Tereza Musilová</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Václav Vafek</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Tamara Skříšovská</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Jana Djakow</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Martina Kosinová</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Pavla Havránková</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Petr Štourač</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Children</subfield><subfield code="d">MDPI AG, 2014</subfield><subfield code="g">9(2022), 10, p 1490</subfield><subfield code="w">(DE-627)768093007</subfield><subfield code="w">(DE-600)2732685-8</subfield><subfield code="x">22279067</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:9</subfield><subfield code="g">year:2022</subfield><subfield code="g">number:10, p 1490</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3390/children9101490</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://www.mdpi.com/2227-9067/9/10/1490</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2227-9067</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">9</subfield><subfield code="j">2022</subfield><subfield code="e">10, p 1490</subfield></datafield></record></collection>
|
callnumber-first |
R - Medicine |
author |
Eva Klabusayová |
spellingShingle |
Eva Klabusayová misc RJ1-570 misc cuff misc airway management misc pediatric patient misc uncuffed tube misc cuffed tube misc Pediatrics Airway Management in Pediatric Patients: Cuff-Solved Problem? |
authorStr |
Eva Klabusayová |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)768093007 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut aut aut aut |
collection |
DOAJ |
remote_str |
true |
callnumber-label |
RJ1-570 |
illustrated |
Not Illustrated |
issn |
22279067 |
topic_title |
RJ1-570 Airway Management in Pediatric Patients: Cuff-Solved Problem? cuff airway management pediatric patient uncuffed tube cuffed tube |
topic |
misc RJ1-570 misc cuff misc airway management misc pediatric patient misc uncuffed tube misc cuffed tube misc Pediatrics |
topic_unstemmed |
misc RJ1-570 misc cuff misc airway management misc pediatric patient misc uncuffed tube misc cuffed tube misc Pediatrics |
topic_browse |
misc RJ1-570 misc cuff misc airway management misc pediatric patient misc uncuffed tube misc cuffed tube misc Pediatrics |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Children |
hierarchy_parent_id |
768093007 |
hierarchy_top_title |
Children |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)768093007 (DE-600)2732685-8 |
title |
Airway Management in Pediatric Patients: Cuff-Solved Problem? |
ctrlnum |
(DE-627)DOAJ020992939 (DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e |
title_full |
Airway Management in Pediatric Patients: Cuff-Solved Problem? |
author_sort |
Eva Klabusayová |
journal |
Children |
journalStr |
Children |
callnumber-first-code |
R |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2022 |
contenttype_str_mv |
txt |
author_browse |
Eva Klabusayová Jozef Klučka Milan Kratochvíl Tereza Musilová Václav Vafek Tamara Skříšovská Jana Djakow Martina Kosinová Pavla Havránková Petr Štourač |
container_volume |
9 |
class |
RJ1-570 |
format_se |
Elektronische Aufsätze |
author-letter |
Eva Klabusayová |
doi_str_mv |
10.3390/children9101490 |
author2-role |
verfasserin |
title_sort |
airway management in pediatric patients: cuff-solved problem? |
callnumber |
RJ1-570 |
title_auth |
Airway Management in Pediatric Patients: Cuff-Solved Problem? |
abstract |
Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. |
abstractGer |
Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. |
abstract_unstemmed |
Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
10, p 1490 |
title_short |
Airway Management in Pediatric Patients: Cuff-Solved Problem? |
url |
https://doi.org/10.3390/children9101490 https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e https://www.mdpi.com/2227-9067/9/10/1490 https://doaj.org/toc/2227-9067 |
remote_bool |
true |
author2 |
Jozef Klučka Milan Kratochvíl Tereza Musilová Václav Vafek Tamara Skříšovská Jana Djakow Martina Kosinová Pavla Havránková Petr Štourač |
author2Str |
Jozef Klučka Milan Kratochvíl Tereza Musilová Václav Vafek Tamara Skříšovská Jana Djakow Martina Kosinová Pavla Havránková Petr Štourač |
ppnlink |
768093007 |
callnumber-subject |
RJ - Pediatrics |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.3390/children9101490 |
callnumber-a |
RJ1-570 |
up_date |
2024-07-03T18:14:19.468Z |
_version_ |
1803582659077603328 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ020992939</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20240414180813.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230226s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3390/children9101490</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ020992939</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJe77d9b67a4e044e3b1d9570c6401a67e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RJ1-570</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Eva Klabusayová</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Airway Management in Pediatric Patients: Cuff-Solved Problem?</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Traditionally, uncuffed tubes were used in pediatric patients under 8 years in pursuit of reducing the risk of postextubation stridor. Although computed tomography and magnetic resonance imaging studies confirmed that the subglottic area remains the narrowest part of pediatric airway, the use of uncuffed tubes failed to reduce the risk of subglottic swelling. Properly used cuffed tubes (correct size and correct cuff management) are currently recommended as the first option in emergency, anesthesiology and intensive care in all pediatric patients. Clinical practice particularly in the intensive care area remains variable. This review aims to analyze the current recommendation for airway management in children in emergency, anesthesiology and intensive care settings.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">cuff</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">airway management</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">pediatric patient</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">uncuffed tube</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">cuffed tube</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Pediatrics</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Jozef Klučka</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Milan Kratochvíl</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Tereza Musilová</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Václav Vafek</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Tamara Skříšovská</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Jana Djakow</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Martina Kosinová</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Pavla Havránková</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Petr Štourač</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Children</subfield><subfield code="d">MDPI AG, 2014</subfield><subfield code="g">9(2022), 10, p 1490</subfield><subfield code="w">(DE-627)768093007</subfield><subfield code="w">(DE-600)2732685-8</subfield><subfield code="x">22279067</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:9</subfield><subfield code="g">year:2022</subfield><subfield code="g">number:10, p 1490</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3390/children9101490</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/e77d9b67a4e044e3b1d9570c6401a67e</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://www.mdpi.com/2227-9067/9/10/1490</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2227-9067</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">9</subfield><subfield code="j">2022</subfield><subfield code="e">10, p 1490</subfield></datafield></record></collection>
|
score |
7.4004107 |