Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer
Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality...
Ausführliche Beschreibung
Autor*in: |
Lise Lecointre [verfasserIn] Juan Verde [verfasserIn] Fabrice Hubele [verfasserIn] Julien Salvadori [verfasserIn] Laurent Goffin [verfasserIn] Chérif Akladios [verfasserIn] Benoît Gallix [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2022 |
---|
Übergeordnetes Werk: |
In: EJNMMI Physics - SpringerOpen, 2015, 9(2022), 1, Seite 8 |
---|---|
Übergeordnetes Werk: |
volume:9 ; year:2022 ; number:1 ; pages:8 |
Links: |
---|
DOI / URN: |
10.1186/s40658-022-00506-7 |
---|
Katalog-ID: |
DOAJ025625438 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ025625438 | ||
003 | DE-627 | ||
005 | 20230307090728.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230226s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/s40658-022-00506-7 |2 doi | |
035 | |a (DE-627)DOAJ025625438 | ||
035 | |a (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
050 | 0 | |a R895-920 | |
100 | 0 | |a Lise Lecointre |e verfasserin |4 aut | |
245 | 1 | 0 | |a Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. | ||
653 | 0 | |a Medical physics. Medical radiology. Nuclear medicine | |
700 | 0 | |a Juan Verde |e verfasserin |4 aut | |
700 | 0 | |a Fabrice Hubele |e verfasserin |4 aut | |
700 | 0 | |a Julien Salvadori |e verfasserin |4 aut | |
700 | 0 | |a Laurent Goffin |e verfasserin |4 aut | |
700 | 0 | |a Chérif Akladios |e verfasserin |4 aut | |
700 | 0 | |a Benoît Gallix |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t EJNMMI Physics |d SpringerOpen, 2015 |g 9(2022), 1, Seite 8 |w (DE-627)785697993 |w (DE-600)2768912-8 |x 21977364 |7 nnns |
773 | 1 | 8 | |g volume:9 |g year:2022 |g number:1 |g pages:8 |
856 | 4 | 0 | |u https://doi.org/10.1186/s40658-022-00506-7 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d |z kostenfrei |
856 | 4 | 0 | |u https://doi.org/10.1186/s40658-022-00506-7 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2197-7364 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2446 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 9 |j 2022 |e 1 |h 8 |
author_variant |
l l ll j v jv f h fh j s js l g lg c a ca b g bg |
---|---|
matchkey_str |
article:21977364:2022----::roeaiepccitaprtvcfsoealnsriaagetdeltttresni |
hierarchy_sort_str |
2022 |
callnumber-subject-code |
R |
publishDate |
2022 |
allfields |
10.1186/s40658-022-00506-7 doi (DE-627)DOAJ025625438 (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d DE-627 ger DE-627 rakwb eng R895-920 Lise Lecointre verfasserin aut Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. Medical physics. Medical radiology. Nuclear medicine Juan Verde verfasserin aut Fabrice Hubele verfasserin aut Julien Salvadori verfasserin aut Laurent Goffin verfasserin aut Chérif Akladios verfasserin aut Benoît Gallix verfasserin aut In EJNMMI Physics SpringerOpen, 2015 9(2022), 1, Seite 8 (DE-627)785697993 (DE-600)2768912-8 21977364 nnns volume:9 year:2022 number:1 pages:8 https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d kostenfrei https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/toc/2197-7364 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2111 GBV_ILN_2446 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 1 8 |
spelling |
10.1186/s40658-022-00506-7 doi (DE-627)DOAJ025625438 (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d DE-627 ger DE-627 rakwb eng R895-920 Lise Lecointre verfasserin aut Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. Medical physics. Medical radiology. Nuclear medicine Juan Verde verfasserin aut Fabrice Hubele verfasserin aut Julien Salvadori verfasserin aut Laurent Goffin verfasserin aut Chérif Akladios verfasserin aut Benoît Gallix verfasserin aut In EJNMMI Physics SpringerOpen, 2015 9(2022), 1, Seite 8 (DE-627)785697993 (DE-600)2768912-8 21977364 nnns volume:9 year:2022 number:1 pages:8 https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d kostenfrei https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/toc/2197-7364 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2111 GBV_ILN_2446 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 1 8 |
allfields_unstemmed |
10.1186/s40658-022-00506-7 doi (DE-627)DOAJ025625438 (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d DE-627 ger DE-627 rakwb eng R895-920 Lise Lecointre verfasserin aut Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. Medical physics. Medical radiology. Nuclear medicine Juan Verde verfasserin aut Fabrice Hubele verfasserin aut Julien Salvadori verfasserin aut Laurent Goffin verfasserin aut Chérif Akladios verfasserin aut Benoît Gallix verfasserin aut In EJNMMI Physics SpringerOpen, 2015 9(2022), 1, Seite 8 (DE-627)785697993 (DE-600)2768912-8 21977364 nnns volume:9 year:2022 number:1 pages:8 https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d kostenfrei https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/toc/2197-7364 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2111 GBV_ILN_2446 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 1 8 |
allfieldsGer |
10.1186/s40658-022-00506-7 doi (DE-627)DOAJ025625438 (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d DE-627 ger DE-627 rakwb eng R895-920 Lise Lecointre verfasserin aut Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. Medical physics. Medical radiology. Nuclear medicine Juan Verde verfasserin aut Fabrice Hubele verfasserin aut Julien Salvadori verfasserin aut Laurent Goffin verfasserin aut Chérif Akladios verfasserin aut Benoît Gallix verfasserin aut In EJNMMI Physics SpringerOpen, 2015 9(2022), 1, Seite 8 (DE-627)785697993 (DE-600)2768912-8 21977364 nnns volume:9 year:2022 number:1 pages:8 https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d kostenfrei https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/toc/2197-7364 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2111 GBV_ILN_2446 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 1 8 |
allfieldsSound |
10.1186/s40658-022-00506-7 doi (DE-627)DOAJ025625438 (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d DE-627 ger DE-627 rakwb eng R895-920 Lise Lecointre verfasserin aut Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. Medical physics. Medical radiology. Nuclear medicine Juan Verde verfasserin aut Fabrice Hubele verfasserin aut Julien Salvadori verfasserin aut Laurent Goffin verfasserin aut Chérif Akladios verfasserin aut Benoît Gallix verfasserin aut In EJNMMI Physics SpringerOpen, 2015 9(2022), 1, Seite 8 (DE-627)785697993 (DE-600)2768912-8 21977364 nnns volume:9 year:2022 number:1 pages:8 https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d kostenfrei https://doi.org/10.1186/s40658-022-00506-7 kostenfrei https://doaj.org/toc/2197-7364 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2111 GBV_ILN_2446 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 9 2022 1 8 |
language |
English |
source |
In EJNMMI Physics 9(2022), 1, Seite 8 volume:9 year:2022 number:1 pages:8 |
sourceStr |
In EJNMMI Physics 9(2022), 1, Seite 8 volume:9 year:2022 number:1 pages:8 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Medical physics. Medical radiology. Nuclear medicine |
isfreeaccess_bool |
true |
container_title |
EJNMMI Physics |
authorswithroles_txt_mv |
Lise Lecointre @@aut@@ Juan Verde @@aut@@ Fabrice Hubele @@aut@@ Julien Salvadori @@aut@@ Laurent Goffin @@aut@@ Chérif Akladios @@aut@@ Benoît Gallix @@aut@@ |
publishDateDaySort_date |
2022-01-01T00:00:00Z |
hierarchy_top_id |
785697993 |
id |
DOAJ025625438 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ025625438</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230307090728.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230226s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s40658-022-00506-7</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ025625438</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">R895-920</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Lise Lecointre</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations.</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Medical physics. Medical radiology. Nuclear medicine</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Juan Verde</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Fabrice Hubele</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Julien Salvadori</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Laurent Goffin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Chérif Akladios</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Benoît Gallix</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">EJNMMI Physics</subfield><subfield code="d">SpringerOpen, 2015</subfield><subfield code="g">9(2022), 1, Seite 8</subfield><subfield code="w">(DE-627)785697993</subfield><subfield code="w">(DE-600)2768912-8</subfield><subfield code="x">21977364</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:9</subfield><subfield code="g">year:2022</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1186/s40658-022-00506-7</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1186/s40658-022-00506-7</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2197-7364</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">9</subfield><subfield code="j">2022</subfield><subfield code="e">1</subfield><subfield code="h">8</subfield></datafield></record></collection>
|
callnumber-first |
R - Medicine |
author |
Lise Lecointre |
spellingShingle |
Lise Lecointre misc R895-920 misc Medical physics. Medical radiology. Nuclear medicine Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
authorStr |
Lise Lecointre |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)785697993 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut |
collection |
DOAJ |
remote_str |
true |
callnumber-label |
R895-920 |
illustrated |
Not Illustrated |
issn |
21977364 |
topic_title |
R895-920 Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
topic |
misc R895-920 misc Medical physics. Medical radiology. Nuclear medicine |
topic_unstemmed |
misc R895-920 misc Medical physics. Medical radiology. Nuclear medicine |
topic_browse |
misc R895-920 misc Medical physics. Medical radiology. Nuclear medicine |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
EJNMMI Physics |
hierarchy_parent_id |
785697993 |
hierarchy_top_title |
EJNMMI Physics |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)785697993 (DE-600)2768912-8 |
title |
Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
ctrlnum |
(DE-627)DOAJ025625438 (DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d |
title_full |
Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
author_sort |
Lise Lecointre |
journal |
EJNMMI Physics |
journalStr |
EJNMMI Physics |
callnumber-first-code |
R |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2022 |
contenttype_str_mv |
txt |
container_start_page |
8 |
author_browse |
Lise Lecointre Juan Verde Fabrice Hubele Julien Salvadori Laurent Goffin Chérif Akladios Benoît Gallix |
container_volume |
9 |
class |
R895-920 |
format_se |
Elektronische Aufsätze |
author-letter |
Lise Lecointre |
doi_str_mv |
10.1186/s40658-022-00506-7 |
author2-role |
verfasserin |
title_sort |
preoperative spect/ct + intraoperative ct fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
callnumber |
R895-920 |
title_auth |
Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
abstract |
Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. |
abstractGer |
Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. |
abstract_unstemmed |
Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2111 GBV_ILN_2446 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
1 |
title_short |
Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer |
url |
https://doi.org/10.1186/s40658-022-00506-7 https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d https://doaj.org/toc/2197-7364 |
remote_bool |
true |
author2 |
Juan Verde Fabrice Hubele Julien Salvadori Laurent Goffin Chérif Akladios Benoît Gallix |
author2Str |
Juan Verde Fabrice Hubele Julien Salvadori Laurent Goffin Chérif Akladios Benoît Gallix |
ppnlink |
785697993 |
callnumber-subject |
R - General Medicine |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.1186/s40658-022-00506-7 |
callnumber-a |
R895-920 |
up_date |
2024-07-03T16:08:29.898Z |
_version_ |
1803574742772350976 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ025625438</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230307090728.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230226s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s40658-022-00506-7</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ025625438</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ3b1c572bd7bd4f799fcb594ca28a7f2d</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">R895-920</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Lise Lecointre</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Preoperative SPECT/CT + intraoperative CT fusion enabling surgical augmented reality to target sentinel lymph node in endometrial cancer</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Purpose To establish a proof-of-concept study using a phantom model to allow the fusion of preoperative single-photon emission computed tomography (SPECT) combined with computed tomography (CT), also known as SPECT/CT, with intraoperative CT, enabling the application of an augmented reality (AR) surgical guidance system for pelvic sentinel lymph node (SLN) detection in endometrial cancer patients. Methods A three-dimensional (3D) pelvic phantom model printed in a gelatin-based scaffold including a radiopaque pelvis, a vascular tree mimicking the iliac vessels, two 3D-printed fillable spheres representing the target pelvic sentinel lymph nodes, and a calibration board was developed. A planar with SPECT/CT lymphoscintigraphy and CT were performed independently on the model. We performed all the necessary steps to achieve the fusion between SPECT/CT and CT. Then, we performed a laparoscopy of the pelvic anatomy on the phantom model to assess in real time the overlay of the recording on the anatomical structures and AR guidance system performance. Results We have successfully completed all the steps needed to fuse the two imaging procedures. This allowed us to apply, in real time, our surgical guidance system with the coverage rate of the visible surface by the augmented reality surface, respectively, on the left SLN 99.48% and on the right SLN 99.42%. Conclusion Co-registration and real-time fusion between a preoperative SPECT/CT and intraoperative CT are feasible. The metric performance of our guidance system is excellent in relation to possible SPECT/CT and CT fusion. Based on our results, we are able to translate the technology to patients, and we initiated a clinical study to evaluate the accuracy of the AR guidance system for endometrial cancer surgery, with a correlation with indocyanine green (ICG)-based technique, representing the gold standard today in the intraoperative detection of SLN in endometrial cancers, despite various limitations.</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Medical physics. Medical radiology. Nuclear medicine</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Juan Verde</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Fabrice Hubele</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Julien Salvadori</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Laurent Goffin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Chérif Akladios</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Benoît Gallix</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">EJNMMI Physics</subfield><subfield code="d">SpringerOpen, 2015</subfield><subfield code="g">9(2022), 1, Seite 8</subfield><subfield code="w">(DE-627)785697993</subfield><subfield code="w">(DE-600)2768912-8</subfield><subfield code="x">21977364</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:9</subfield><subfield code="g">year:2022</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1186/s40658-022-00506-7</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/3b1c572bd7bd4f799fcb594ca28a7f2d</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1186/s40658-022-00506-7</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2197-7364</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2446</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">9</subfield><subfield code="j">2022</subfield><subfield code="e">1</subfield><subfield code="h">8</subfield></datafield></record></collection>
|
score |
7.399207 |