THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE
In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen perme...
Ausführliche Beschreibung
Autor*in: |
Yu. S. Levchenko [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Russisch |
Erschienen: |
2018 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
In: Российский офтальмологический журнал - Real Time Ltd, 2020, 11(2018), 2, Seite 87-94 |
---|---|
Übergeordnetes Werk: |
volume:11 ; year:2018 ; number:2 ; pages:87-94 |
Links: |
Link aufrufen |
---|
DOI / URN: |
10.21516/2072-0076-2018-11-2-87-94 |
---|
Katalog-ID: |
DOAJ027000907 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ027000907 | ||
003 | DE-627 | ||
005 | 20230410121228.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230226s2018 xx |||||o 00| ||rus c | ||
024 | 7 | |a 10.21516/2072-0076-2018-11-2-87-94 |2 doi | |
035 | |a (DE-627)DOAJ027000907 | ||
035 | |a (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a rus | ||
050 | 0 | |a RE1-994 | |
100 | 0 | |a Yu. S. Levchenko |e verfasserin |4 aut | |
245 | 1 | 4 | |a THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE |
264 | 1 | |c 2018 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). | ||
650 | 4 | |a ортокератология | |
650 | 4 | |a безопасность ортокератологии | |
650 | 4 | |a осложнения | |
650 | 4 | |a миопия | |
650 | 4 | |a orthokeratology | |
650 | 4 | |a orthokeratology safety | |
650 | 4 | |a complications | |
650 | 4 | |a myopia | |
653 | 0 | |a Ophthalmology | |
773 | 0 | 8 | |i In |t Российский офтальмологический журнал |d Real Time Ltd, 2020 |g 11(2018), 2, Seite 87-94 |w (DE-627)176061162X |x 25875760 |7 nnns |
773 | 1 | 8 | |g volume:11 |g year:2018 |g number:2 |g pages:87-94 |
856 | 4 | 0 | |u https://doi.org/10.21516/2072-0076-2018-11-2-87-94 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a |z kostenfrei |
856 | 4 | 0 | |u https://roj.igb.ru/jour/article/view/160 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2072-0076 |y Journal toc |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2587-5760 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
951 | |a AR | ||
952 | |d 11 |j 2018 |e 2 |h 87-94 |
author_variant |
y s l ysl |
---|---|
matchkey_str |
article:25875760:2018----::hsftisefrhkrtlgapiainn |
hierarchy_sort_str |
2018 |
callnumber-subject-code |
RE |
publishDate |
2018 |
allfields |
10.21516/2072-0076-2018-11-2-87-94 doi (DE-627)DOAJ027000907 (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a DE-627 ger DE-627 rakwb rus RE1-994 Yu. S. Levchenko verfasserin aut THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia Ophthalmology In Российский офтальмологический журнал Real Time Ltd, 2020 11(2018), 2, Seite 87-94 (DE-627)176061162X 25875760 nnns volume:11 year:2018 number:2 pages:87-94 https://doi.org/10.21516/2072-0076-2018-11-2-87-94 kostenfrei https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a kostenfrei https://roj.igb.ru/jour/article/view/160 kostenfrei https://doaj.org/toc/2072-0076 Journal toc kostenfrei https://doaj.org/toc/2587-5760 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ AR 11 2018 2 87-94 |
spelling |
10.21516/2072-0076-2018-11-2-87-94 doi (DE-627)DOAJ027000907 (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a DE-627 ger DE-627 rakwb rus RE1-994 Yu. S. Levchenko verfasserin aut THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia Ophthalmology In Российский офтальмологический журнал Real Time Ltd, 2020 11(2018), 2, Seite 87-94 (DE-627)176061162X 25875760 nnns volume:11 year:2018 number:2 pages:87-94 https://doi.org/10.21516/2072-0076-2018-11-2-87-94 kostenfrei https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a kostenfrei https://roj.igb.ru/jour/article/view/160 kostenfrei https://doaj.org/toc/2072-0076 Journal toc kostenfrei https://doaj.org/toc/2587-5760 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ AR 11 2018 2 87-94 |
allfields_unstemmed |
10.21516/2072-0076-2018-11-2-87-94 doi (DE-627)DOAJ027000907 (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a DE-627 ger DE-627 rakwb rus RE1-994 Yu. S. Levchenko verfasserin aut THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia Ophthalmology In Российский офтальмологический журнал Real Time Ltd, 2020 11(2018), 2, Seite 87-94 (DE-627)176061162X 25875760 nnns volume:11 year:2018 number:2 pages:87-94 https://doi.org/10.21516/2072-0076-2018-11-2-87-94 kostenfrei https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a kostenfrei https://roj.igb.ru/jour/article/view/160 kostenfrei https://doaj.org/toc/2072-0076 Journal toc kostenfrei https://doaj.org/toc/2587-5760 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ AR 11 2018 2 87-94 |
allfieldsGer |
10.21516/2072-0076-2018-11-2-87-94 doi (DE-627)DOAJ027000907 (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a DE-627 ger DE-627 rakwb rus RE1-994 Yu. S. Levchenko verfasserin aut THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia Ophthalmology In Российский офтальмологический журнал Real Time Ltd, 2020 11(2018), 2, Seite 87-94 (DE-627)176061162X 25875760 nnns volume:11 year:2018 number:2 pages:87-94 https://doi.org/10.21516/2072-0076-2018-11-2-87-94 kostenfrei https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a kostenfrei https://roj.igb.ru/jour/article/view/160 kostenfrei https://doaj.org/toc/2072-0076 Journal toc kostenfrei https://doaj.org/toc/2587-5760 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ AR 11 2018 2 87-94 |
allfieldsSound |
10.21516/2072-0076-2018-11-2-87-94 doi (DE-627)DOAJ027000907 (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a DE-627 ger DE-627 rakwb rus RE1-994 Yu. S. Levchenko verfasserin aut THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE 2018 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia Ophthalmology In Российский офтальмологический журнал Real Time Ltd, 2020 11(2018), 2, Seite 87-94 (DE-627)176061162X 25875760 nnns volume:11 year:2018 number:2 pages:87-94 https://doi.org/10.21516/2072-0076-2018-11-2-87-94 kostenfrei https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a kostenfrei https://roj.igb.ru/jour/article/view/160 kostenfrei https://doaj.org/toc/2072-0076 Journal toc kostenfrei https://doaj.org/toc/2587-5760 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ AR 11 2018 2 87-94 |
language |
Russian |
source |
In Российский офтальмологический журнал 11(2018), 2, Seite 87-94 volume:11 year:2018 number:2 pages:87-94 |
sourceStr |
In Российский офтальмологический журнал 11(2018), 2, Seite 87-94 volume:11 year:2018 number:2 pages:87-94 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia Ophthalmology |
isfreeaccess_bool |
true |
container_title |
Российский офтальмологический журнал |
authorswithroles_txt_mv |
Yu. S. Levchenko @@aut@@ |
publishDateDaySort_date |
2018-01-01T00:00:00Z |
hierarchy_top_id |
176061162X |
id |
DOAJ027000907 |
language_de |
russisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ027000907</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230410121228.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230226s2018 xx |||||o 00| ||rus c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.21516/2072-0076-2018-11-2-87-94</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ027000907</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">rus</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RE1-994</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Yu. S. Levchenko</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="4"><subfield code="a">THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian).</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">ортокератология</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">безопасность ортокератологии</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">осложнения</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">миопия</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">orthokeratology</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">orthokeratology safety</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">complications</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">myopia</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Ophthalmology</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Российский офтальмологический журнал</subfield><subfield code="d">Real Time Ltd, 2020</subfield><subfield code="g">11(2018), 2, Seite 87-94</subfield><subfield code="w">(DE-627)176061162X</subfield><subfield code="x">25875760</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:11</subfield><subfield code="g">year:2018</subfield><subfield code="g">number:2</subfield><subfield code="g">pages:87-94</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.21516/2072-0076-2018-11-2-87-94</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://roj.igb.ru/jour/article/view/160</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2072-0076</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2587-5760</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">11</subfield><subfield code="j">2018</subfield><subfield code="e">2</subfield><subfield code="h">87-94</subfield></datafield></record></collection>
|
callnumber-first |
R - Medicine |
author |
Yu. S. Levchenko |
spellingShingle |
Yu. S. Levchenko misc RE1-994 misc ортокератология misc безопасность ортокератологии misc осложнения misc миопия misc orthokeratology misc orthokeratology safety misc complications misc myopia misc Ophthalmology THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE |
authorStr |
Yu. S. Levchenko |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)176061162X |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut |
collection |
DOAJ |
remote_str |
true |
callnumber-label |
RE1-994 |
illustrated |
Not Illustrated |
issn |
25875760 |
topic_title |
RE1-994 THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE ортокератология безопасность ортокератологии осложнения миопия orthokeratology orthokeratology safety complications myopia |
topic |
misc RE1-994 misc ортокератология misc безопасность ортокератологии misc осложнения misc миопия misc orthokeratology misc orthokeratology safety misc complications misc myopia misc Ophthalmology |
topic_unstemmed |
misc RE1-994 misc ортокератология misc безопасность ортокератологии misc осложнения misc миопия misc orthokeratology misc orthokeratology safety misc complications misc myopia misc Ophthalmology |
topic_browse |
misc RE1-994 misc ортокератология misc безопасность ортокератологии misc осложнения misc миопия misc orthokeratology misc orthokeratology safety misc complications misc myopia misc Ophthalmology |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Российский офтальмологический журнал |
hierarchy_parent_id |
176061162X |
hierarchy_top_title |
Российский офтальмологический журнал |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)176061162X |
title |
THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE |
ctrlnum |
(DE-627)DOAJ027000907 (DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a |
title_full |
THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE |
author_sort |
Yu. S. Levchenko |
journal |
Российский офтальмологический журнал |
journalStr |
Российский офтальмологический журнал |
callnumber-first-code |
R |
lang_code |
rus |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2018 |
contenttype_str_mv |
txt |
container_start_page |
87 |
author_browse |
Yu. S. Levchenko |
container_volume |
11 |
class |
RE1-994 |
format_se |
Elektronische Aufsätze |
author-letter |
Yu. S. Levchenko |
doi_str_mv |
10.21516/2072-0076-2018-11-2-87-94 |
title_sort |
safety issue of orthokeratology application in clinical practice |
callnumber |
RE1-994 |
title_auth |
THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE |
abstract |
In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). |
abstractGer |
In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). |
abstract_unstemmed |
In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian). |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ |
container_issue |
2 |
title_short |
THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE |
url |
https://doi.org/10.21516/2072-0076-2018-11-2-87-94 https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a https://roj.igb.ru/jour/article/view/160 https://doaj.org/toc/2072-0076 https://doaj.org/toc/2587-5760 |
remote_bool |
true |
ppnlink |
176061162X |
callnumber-subject |
RE - Ophthalmology |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.21516/2072-0076-2018-11-2-87-94 |
callnumber-a |
RE1-994 |
up_date |
2024-07-03T23:58:00.316Z |
_version_ |
1803604281594478592 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ027000907</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230410121228.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230226s2018 xx |||||o 00| ||rus c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.21516/2072-0076-2018-11-2-87-94</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ027000907</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ9e8b073a8d904421a38c6b57da562d5a</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">rus</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RE1-994</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Yu. S. Levchenko</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="4"><subfield code="a">THE SAFETY ISSUE OF ORTHOKERATOLOGY APPLICATION IN CLINICAL PRACTICE</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">In recent years, application of night orthokeratological contact lenses (OK lenses) is becoming more and more widespread the world over. Modern orthokeratology makes use of gas-permeable contact lenses of reverse geometry: these are sophisticated structures made from materials with high oxygen permeability. The change of the curvature of the external corneal surface and, as a result, ocular refraction changes caused by OK lenses occurs due to changing architectonics of the corneal epithelium. The safety of orthokeratology is a pressing issue. The percentage of revealed complications in patients wearing OK lenses is comparable to, and in some cases, is even lower than with other means of vision correction. If the choice of OK lenses is adequate and the patient wearing them complies with wearing instructions and maintenance rules, their long use does not entail clinically significant complications. The results of the study emphasize the importance of a careful choice of OK lenses and regular medical checkups of patients. For citation: Levchenko Yu.S. The safety issue of orthokeratology application in clinical practice. Russian ophthalmological journal. 2018; 11 (2): 87-94. doi: 10.21516/2072-0076-2018-11-2-87-94 (In Russian).</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">ортокератология</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">безопасность ортокератологии</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">осложнения</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">миопия</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">orthokeratology</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">orthokeratology safety</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">complications</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">myopia</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Ophthalmology</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Российский офтальмологический журнал</subfield><subfield code="d">Real Time Ltd, 2020</subfield><subfield code="g">11(2018), 2, Seite 87-94</subfield><subfield code="w">(DE-627)176061162X</subfield><subfield code="x">25875760</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:11</subfield><subfield code="g">year:2018</subfield><subfield code="g">number:2</subfield><subfield code="g">pages:87-94</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.21516/2072-0076-2018-11-2-87-94</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/9e8b073a8d904421a38c6b57da562d5a</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://roj.igb.ru/jour/article/view/160</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2072-0076</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2587-5760</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">11</subfield><subfield code="j">2018</subfield><subfield code="e">2</subfield><subfield code="h">87-94</subfield></datafield></record></collection>
|
score |
7.401967 |