Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population
Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative st...
Ausführliche Beschreibung
Autor*in: |
Hyeck-Soo Son [verfasserIn] Seong Ho Kim [verfasserIn] Gerd U. Auffarth [verfasserIn] Chul Young Choi [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2019 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
In: BMC Ophthalmology - BMC, 2003, 19(2019), 1, Seite 10 |
---|---|
Übergeordnetes Werk: |
volume:19 ; year:2019 ; number:1 ; pages:10 |
Links: |
---|
DOI / URN: |
10.1186/s12886-019-1193-z |
---|
Katalog-ID: |
DOAJ037256785 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ037256785 | ||
003 | DE-627 | ||
005 | 20230308001949.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230227s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1186/s12886-019-1193-z |2 doi | |
035 | |a (DE-627)DOAJ037256785 | ||
035 | |a (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
050 | 0 | |a RE1-994 | |
100 | 0 | |a Hyeck-Soo Son |e verfasserin |4 aut | |
245 | 1 | 0 | |a Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. | ||
650 | 4 | |a Extended depth of focus IOL | |
650 | 4 | |a Symfony | |
650 | 4 | |a ZXR00 | |
650 | 4 | |a Visual acuity tolerance to postoperative refractive errors | |
653 | 0 | |a Ophthalmology | |
700 | 0 | |a Seong Ho Kim |e verfasserin |4 aut | |
700 | 0 | |a Gerd U. Auffarth |e verfasserin |4 aut | |
700 | 0 | |a Chul Young Choi |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t BMC Ophthalmology |d BMC, 2003 |g 19(2019), 1, Seite 10 |w (DE-627)331018772 |w (DE-600)2050436-6 |x 14712415 |7 nnns |
773 | 1 | 8 | |g volume:19 |g year:2019 |g number:1 |g pages:10 |
856 | 4 | 0 | |u https://doi.org/10.1186/s12886-019-1193-z |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e |z kostenfrei |
856 | 4 | 0 | |u http://link.springer.com/article/10.1186/s12886-019-1193-z |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/1471-2415 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a GBV_ILN_11 | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 19 |j 2019 |e 1 |h 10 |
author_variant |
h s s hss s h k shk g u a gua c y c cyc |
---|---|
matchkey_str |
article:14712415:2019----::rsetvcmaaietdotlrneoercierosfeipattooetnedphfouadoooaitaclressi |
hierarchy_sort_str |
2019 |
callnumber-subject-code |
RE |
publishDate |
2019 |
allfields |
10.1186/s12886-019-1193-z doi (DE-627)DOAJ037256785 (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e DE-627 ger DE-627 rakwb eng RE1-994 Hyeck-Soo Son verfasserin aut Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors Ophthalmology Seong Ho Kim verfasserin aut Gerd U. Auffarth verfasserin aut Chul Young Choi verfasserin aut In BMC Ophthalmology BMC, 2003 19(2019), 1, Seite 10 (DE-627)331018772 (DE-600)2050436-6 14712415 nnns volume:19 year:2019 number:1 pages:10 https://doi.org/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e kostenfrei http://link.springer.com/article/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/toc/1471-2415 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 19 2019 1 10 |
spelling |
10.1186/s12886-019-1193-z doi (DE-627)DOAJ037256785 (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e DE-627 ger DE-627 rakwb eng RE1-994 Hyeck-Soo Son verfasserin aut Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors Ophthalmology Seong Ho Kim verfasserin aut Gerd U. Auffarth verfasserin aut Chul Young Choi verfasserin aut In BMC Ophthalmology BMC, 2003 19(2019), 1, Seite 10 (DE-627)331018772 (DE-600)2050436-6 14712415 nnns volume:19 year:2019 number:1 pages:10 https://doi.org/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e kostenfrei http://link.springer.com/article/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/toc/1471-2415 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 19 2019 1 10 |
allfields_unstemmed |
10.1186/s12886-019-1193-z doi (DE-627)DOAJ037256785 (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e DE-627 ger DE-627 rakwb eng RE1-994 Hyeck-Soo Son verfasserin aut Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors Ophthalmology Seong Ho Kim verfasserin aut Gerd U. Auffarth verfasserin aut Chul Young Choi verfasserin aut In BMC Ophthalmology BMC, 2003 19(2019), 1, Seite 10 (DE-627)331018772 (DE-600)2050436-6 14712415 nnns volume:19 year:2019 number:1 pages:10 https://doi.org/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e kostenfrei http://link.springer.com/article/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/toc/1471-2415 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 19 2019 1 10 |
allfieldsGer |
10.1186/s12886-019-1193-z doi (DE-627)DOAJ037256785 (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e DE-627 ger DE-627 rakwb eng RE1-994 Hyeck-Soo Son verfasserin aut Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors Ophthalmology Seong Ho Kim verfasserin aut Gerd U. Auffarth verfasserin aut Chul Young Choi verfasserin aut In BMC Ophthalmology BMC, 2003 19(2019), 1, Seite 10 (DE-627)331018772 (DE-600)2050436-6 14712415 nnns volume:19 year:2019 number:1 pages:10 https://doi.org/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e kostenfrei http://link.springer.com/article/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/toc/1471-2415 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 19 2019 1 10 |
allfieldsSound |
10.1186/s12886-019-1193-z doi (DE-627)DOAJ037256785 (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e DE-627 ger DE-627 rakwb eng RE1-994 Hyeck-Soo Son verfasserin aut Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors Ophthalmology Seong Ho Kim verfasserin aut Gerd U. Auffarth verfasserin aut Chul Young Choi verfasserin aut In BMC Ophthalmology BMC, 2003 19(2019), 1, Seite 10 (DE-627)331018772 (DE-600)2050436-6 14712415 nnns volume:19 year:2019 number:1 pages:10 https://doi.org/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e kostenfrei http://link.springer.com/article/10.1186/s12886-019-1193-z kostenfrei https://doaj.org/toc/1471-2415 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 19 2019 1 10 |
language |
English |
source |
In BMC Ophthalmology 19(2019), 1, Seite 10 volume:19 year:2019 number:1 pages:10 |
sourceStr |
In BMC Ophthalmology 19(2019), 1, Seite 10 volume:19 year:2019 number:1 pages:10 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors Ophthalmology |
isfreeaccess_bool |
true |
container_title |
BMC Ophthalmology |
authorswithroles_txt_mv |
Hyeck-Soo Son @@aut@@ Seong Ho Kim @@aut@@ Gerd U. Auffarth @@aut@@ Chul Young Choi @@aut@@ |
publishDateDaySort_date |
2019-01-01T00:00:00Z |
hierarchy_top_id |
331018772 |
id |
DOAJ037256785 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ037256785</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230308001949.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230227s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s12886-019-1193-z</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ037256785</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RE1-994</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Hyeck-Soo Son</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Extended depth of focus IOL</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Symfony</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">ZXR00</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Visual acuity tolerance to postoperative refractive errors</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Ophthalmology</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Seong Ho Kim</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Gerd U. Auffarth</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Chul Young Choi</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">BMC Ophthalmology</subfield><subfield code="d">BMC, 2003</subfield><subfield code="g">19(2019), 1, Seite 10</subfield><subfield code="w">(DE-627)331018772</subfield><subfield code="w">(DE-600)2050436-6</subfield><subfield code="x">14712415</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:19</subfield><subfield code="g">year:2019</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:10</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1186/s12886-019-1193-z</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://link.springer.com/article/10.1186/s12886-019-1193-z</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/1471-2415</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">19</subfield><subfield code="j">2019</subfield><subfield code="e">1</subfield><subfield code="h">10</subfield></datafield></record></collection>
|
callnumber-first |
R - Medicine |
author |
Hyeck-Soo Son |
spellingShingle |
Hyeck-Soo Son misc RE1-994 misc Extended depth of focus IOL misc Symfony misc ZXR00 misc Visual acuity tolerance to postoperative refractive errors misc Ophthalmology Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population |
authorStr |
Hyeck-Soo Son |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)331018772 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut |
collection |
DOAJ |
remote_str |
true |
callnumber-label |
RE1-994 |
illustrated |
Not Illustrated |
issn |
14712415 |
topic_title |
RE1-994 Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population Extended depth of focus IOL Symfony ZXR00 Visual acuity tolerance to postoperative refractive errors |
topic |
misc RE1-994 misc Extended depth of focus IOL misc Symfony misc ZXR00 misc Visual acuity tolerance to postoperative refractive errors misc Ophthalmology |
topic_unstemmed |
misc RE1-994 misc Extended depth of focus IOL misc Symfony misc ZXR00 misc Visual acuity tolerance to postoperative refractive errors misc Ophthalmology |
topic_browse |
misc RE1-994 misc Extended depth of focus IOL misc Symfony misc ZXR00 misc Visual acuity tolerance to postoperative refractive errors misc Ophthalmology |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
BMC Ophthalmology |
hierarchy_parent_id |
331018772 |
hierarchy_top_title |
BMC Ophthalmology |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)331018772 (DE-600)2050436-6 |
title |
Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population |
ctrlnum |
(DE-627)DOAJ037256785 (DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e |
title_full |
Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population |
author_sort |
Hyeck-Soo Son |
journal |
BMC Ophthalmology |
journalStr |
BMC Ophthalmology |
callnumber-first-code |
R |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2019 |
contenttype_str_mv |
txt |
container_start_page |
10 |
author_browse |
Hyeck-Soo Son Seong Ho Kim Gerd U. Auffarth Chul Young Choi |
container_volume |
19 |
class |
RE1-994 |
format_se |
Elektronische Aufsätze |
author-letter |
Hyeck-Soo Son |
doi_str_mv |
10.1186/s12886-019-1193-z |
author2-role |
verfasserin |
title_sort |
prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in korean population |
callnumber |
RE1-994 |
title_auth |
Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population |
abstract |
Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. |
abstractGer |
Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. |
abstract_unstemmed |
Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_11 GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_602 GBV_ILN_2003 GBV_ILN_2014 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
1 |
title_short |
Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population |
url |
https://doi.org/10.1186/s12886-019-1193-z https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e http://link.springer.com/article/10.1186/s12886-019-1193-z https://doaj.org/toc/1471-2415 |
remote_bool |
true |
author2 |
Seong Ho Kim Gerd U. Auffarth Chul Young Choi |
author2Str |
Seong Ho Kim Gerd U. Auffarth Chul Young Choi |
ppnlink |
331018772 |
callnumber-subject |
RE - Ophthalmology |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.1186/s12886-019-1193-z |
callnumber-a |
RE1-994 |
up_date |
2024-07-04T00:31:45.391Z |
_version_ |
1803606405044764672 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ037256785</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230308001949.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230227s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1186/s12886-019-1193-z</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ037256785</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ2de0b63c6266428e9ccce4098b01d46e</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RE1-994</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Hyeck-Soo Son</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Background To evaluate the clinical outcomes of extended depth of focus (EDOF) and monofocal intraocular lenses (IOLs) that share identical aspheric platform and compare their visual acuity tolerance to postoperative refractive errors. Methods This non-randomized, prospective comparative study included 120 eyes undergoing cataract surgery with implantation of either Tecnis ZCB00 IOL (Abbott Medical Optics Inc., Santa Ana, CA) (monofocal group: 60 eyes of 30 patients) or Tecnis Symfony IOL (Abbott Medical Optics, Inc.) (EDOF group: 60 eyes of 30 patients). Monocular and binocular visual outcomes, changes in refraction, defocus curve, contrast sensitivity, and perception of photic phenomena (Halo & Glare Simulator; Eyeland Design Network, Vreden, Germany) were evaluated 3 months postoperatively. To compare the refractive tolerance, each group was divided into three subgroups according to the postoperative uncorrected distance visual acuity (UDVA) and postoperative spherical equivalent (SE). Results In the EDOF group, the mean 3-months postoperative monocular UDVA, intermediate (UIVA), and near (UNVA) visual acuities were 0.03 ± 0.07, 0.09 ± 0.15, and 0.24 ± 0.16 logMAR, respectively. A total of 100, 96.55, and 68.97% of eyes in the EDOF group achieved binocular UDVA, UIVA, and UNVA values of 0.20 logMAR or better, respectively. In respect to refractive tolerance, the EDOF group showed higher SE values and statistically significantly better mean UDVA than the monofocal group in all subgroups, with UDVA of − 0.013 and 0.028 logMAR for EDOF and monofocal groups (p = 0.037), respectively, in the subgroup where SE was within ±0.50 D, UDVA of 0.004 and 0.048 logMAR for EDOF and monofocal groups (p = 0.046), respectively, in the subgroup where SE was within − 1.00 D, and UDVA of 0.020 and 0.083 logMAR for EDOF and monofocal groups (p = 0.026), respectively, in the subgroup where SE was more than − 1.00 D. The mean patient satisfaction scores for spectacle-free distance, intermediate, and near visual acuities were 86.0, 85.0, and 66.0, respectively. Conclusions The EDOF IOL provided excellent postoperative visual outcomes in far and intermediate distances, with high patient satisfaction rate. Regarding the postoperative refractive tolerance to SE, the Tecnis Symfony IOL showed better tolerance to residual postoperative refractive error than the monofocal IOL with the same material and optical platform.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Extended depth of focus IOL</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Symfony</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">ZXR00</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Visual acuity tolerance to postoperative refractive errors</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Ophthalmology</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Seong Ho Kim</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Gerd U. Auffarth</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Chul Young Choi</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">BMC Ophthalmology</subfield><subfield code="d">BMC, 2003</subfield><subfield code="g">19(2019), 1, Seite 10</subfield><subfield code="w">(DE-627)331018772</subfield><subfield code="w">(DE-600)2050436-6</subfield><subfield code="x">14712415</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:19</subfield><subfield code="g">year:2019</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:10</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1186/s12886-019-1193-z</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/2de0b63c6266428e9ccce4098b01d46e</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://link.springer.com/article/10.1186/s12886-019-1193-z</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/1471-2415</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_11</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">19</subfield><subfield code="j">2019</subfield><subfield code="e">1</subfield><subfield code="h">10</subfield></datafield></record></collection>
|
score |
7.399102 |