Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System
Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences,...
Ausführliche Beschreibung
Autor*in: |
Timothy R. Daniels MD, FRCSC [verfasserIn] Shahin Kayum MD, MRCS [verfasserIn] Ryan M. Khan PA [verfasserIn] Anastasia Sanjevic [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2019 |
---|
Übergeordnetes Werk: |
In: Foot & Ankle Orthopaedics - SAGE Publishing, 2018, 4(2019) |
---|---|
Übergeordnetes Werk: |
volume:4 ; year:2019 |
Links: |
---|
DOI / URN: |
10.1177/2473011419S00156 |
---|
Katalog-ID: |
DOAJ053756746 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ053756746 | ||
003 | DE-627 | ||
005 | 20230308175400.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230227s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1177/2473011419S00156 |2 doi | |
035 | |a (DE-627)DOAJ053756746 | ||
035 | |a (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
050 | 0 | |a RD701-811 | |
100 | 0 | |a Timothy R. Daniels MD, FRCSC |e verfasserin |4 aut | |
245 | 1 | 0 | |a Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). | ||
653 | 0 | |a Orthopedic surgery | |
700 | 0 | |a Shahin Kayum MD, MRCS |e verfasserin |4 aut | |
700 | 0 | |a Ryan M. Khan PA |e verfasserin |4 aut | |
700 | 0 | |a Anastasia Sanjevic |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t Foot & Ankle Orthopaedics |d SAGE Publishing, 2018 |g 4(2019) |w (DE-627)872473007 |w (DE-600)2874570-X |x 24730114 |7 nnns |
773 | 1 | 8 | |g volume:4 |g year:2019 |
856 | 4 | 0 | |u https://doi.org/10.1177/2473011419S00156 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab |z kostenfrei |
856 | 4 | 0 | |u https://doi.org/10.1177/2473011419S00156 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/2473-0114 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_374 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2704 | ||
912 | |a GBV_ILN_2707 | ||
912 | |a GBV_ILN_2890 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 4 |j 2019 |
author_variant |
r d m f t rdmf rdmft k m m s kmm kmms r m k p rmkp a s as |
---|---|
matchkey_str |
article:24730114:2019----::wyaotoeottlnlrpaeetihhcdneoa |
hierarchy_sort_str |
2019 |
callnumber-subject-code |
RD |
publishDate |
2019 |
allfields |
10.1177/2473011419S00156 doi (DE-627)DOAJ053756746 (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab DE-627 ger DE-627 rakwb eng RD701-811 Timothy R. Daniels MD, FRCSC verfasserin aut Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). Orthopedic surgery Shahin Kayum MD, MRCS verfasserin aut Ryan M. Khan PA verfasserin aut Anastasia Sanjevic verfasserin aut In Foot & Ankle Orthopaedics SAGE Publishing, 2018 4(2019) (DE-627)872473007 (DE-600)2874570-X 24730114 nnns volume:4 year:2019 https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab kostenfrei https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/toc/2473-0114 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_374 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_2034 GBV_ILN_2068 GBV_ILN_2704 GBV_ILN_2707 GBV_ILN_2890 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 4 2019 |
spelling |
10.1177/2473011419S00156 doi (DE-627)DOAJ053756746 (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab DE-627 ger DE-627 rakwb eng RD701-811 Timothy R. Daniels MD, FRCSC verfasserin aut Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). Orthopedic surgery Shahin Kayum MD, MRCS verfasserin aut Ryan M. Khan PA verfasserin aut Anastasia Sanjevic verfasserin aut In Foot & Ankle Orthopaedics SAGE Publishing, 2018 4(2019) (DE-627)872473007 (DE-600)2874570-X 24730114 nnns volume:4 year:2019 https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab kostenfrei https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/toc/2473-0114 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_374 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_2034 GBV_ILN_2068 GBV_ILN_2704 GBV_ILN_2707 GBV_ILN_2890 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 4 2019 |
allfields_unstemmed |
10.1177/2473011419S00156 doi (DE-627)DOAJ053756746 (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab DE-627 ger DE-627 rakwb eng RD701-811 Timothy R. Daniels MD, FRCSC verfasserin aut Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). Orthopedic surgery Shahin Kayum MD, MRCS verfasserin aut Ryan M. Khan PA verfasserin aut Anastasia Sanjevic verfasserin aut In Foot & Ankle Orthopaedics SAGE Publishing, 2018 4(2019) (DE-627)872473007 (DE-600)2874570-X 24730114 nnns volume:4 year:2019 https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab kostenfrei https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/toc/2473-0114 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_374 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_2034 GBV_ILN_2068 GBV_ILN_2704 GBV_ILN_2707 GBV_ILN_2890 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 4 2019 |
allfieldsGer |
10.1177/2473011419S00156 doi (DE-627)DOAJ053756746 (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab DE-627 ger DE-627 rakwb eng RD701-811 Timothy R. Daniels MD, FRCSC verfasserin aut Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). Orthopedic surgery Shahin Kayum MD, MRCS verfasserin aut Ryan M. Khan PA verfasserin aut Anastasia Sanjevic verfasserin aut In Foot & Ankle Orthopaedics SAGE Publishing, 2018 4(2019) (DE-627)872473007 (DE-600)2874570-X 24730114 nnns volume:4 year:2019 https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab kostenfrei https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/toc/2473-0114 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_374 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_2034 GBV_ILN_2068 GBV_ILN_2704 GBV_ILN_2707 GBV_ILN_2890 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 4 2019 |
allfieldsSound |
10.1177/2473011419S00156 doi (DE-627)DOAJ053756746 (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab DE-627 ger DE-627 rakwb eng RD701-811 Timothy R. Daniels MD, FRCSC verfasserin aut Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System 2019 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). Orthopedic surgery Shahin Kayum MD, MRCS verfasserin aut Ryan M. Khan PA verfasserin aut Anastasia Sanjevic verfasserin aut In Foot & Ankle Orthopaedics SAGE Publishing, 2018 4(2019) (DE-627)872473007 (DE-600)2874570-X 24730114 nnns volume:4 year:2019 https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab kostenfrei https://doi.org/10.1177/2473011419S00156 kostenfrei https://doaj.org/toc/2473-0114 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_374 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_2034 GBV_ILN_2068 GBV_ILN_2704 GBV_ILN_2707 GBV_ILN_2890 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 4 2019 |
language |
English |
source |
In Foot & Ankle Orthopaedics 4(2019) volume:4 year:2019 |
sourceStr |
In Foot & Ankle Orthopaedics 4(2019) volume:4 year:2019 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Orthopedic surgery |
isfreeaccess_bool |
true |
container_title |
Foot & Ankle Orthopaedics |
authorswithroles_txt_mv |
Timothy R. Daniels MD, FRCSC @@aut@@ Shahin Kayum MD, MRCS @@aut@@ Ryan M. Khan PA @@aut@@ Anastasia Sanjevic @@aut@@ |
publishDateDaySort_date |
2019-01-01T00:00:00Z |
hierarchy_top_id |
872473007 |
id |
DOAJ053756746 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ053756746</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230308175400.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230227s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1177/2473011419S00156</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ053756746</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJfb310b0be2ab410d9758b5c91387daab</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RD701-811</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Timothy R. Daniels MD, FRCSC</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus).</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Orthopedic surgery</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Shahin Kayum MD, MRCS</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Ryan M. Khan PA</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Anastasia Sanjevic</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Foot & Ankle Orthopaedics</subfield><subfield code="d">SAGE Publishing, 2018</subfield><subfield code="g">4(2019)</subfield><subfield code="w">(DE-627)872473007</subfield><subfield code="w">(DE-600)2874570-X</subfield><subfield code="x">24730114</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:4</subfield><subfield code="g">year:2019</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1177/2473011419S00156</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1177/2473011419S00156</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2473-0114</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_374</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2704</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2707</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2890</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">4</subfield><subfield code="j">2019</subfield></datafield></record></collection>
|
callnumber-first |
R - Medicine |
author |
Timothy R. Daniels MD, FRCSC |
spellingShingle |
Timothy R. Daniels MD, FRCSC misc RD701-811 misc Orthopedic surgery Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
authorStr |
Timothy R. Daniels MD, FRCSC |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)872473007 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut |
collection |
DOAJ |
remote_str |
true |
callnumber-label |
RD701-811 |
illustrated |
Not Illustrated |
issn |
24730114 |
topic_title |
RD701-811 Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
topic |
misc RD701-811 misc Orthopedic surgery |
topic_unstemmed |
misc RD701-811 misc Orthopedic surgery |
topic_browse |
misc RD701-811 misc Orthopedic surgery |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Foot & Ankle Orthopaedics |
hierarchy_parent_id |
872473007 |
hierarchy_top_title |
Foot & Ankle Orthopaedics |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)872473007 (DE-600)2874570-X |
title |
Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
ctrlnum |
(DE-627)DOAJ053756746 (DE-599)DOAJfb310b0be2ab410d9758b5c91387daab |
title_full |
Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
author_sort |
Timothy R. Daniels MD, FRCSC |
journal |
Foot & Ankle Orthopaedics |
journalStr |
Foot & Ankle Orthopaedics |
callnumber-first-code |
R |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2019 |
contenttype_str_mv |
txt |
author_browse |
Timothy R. Daniels MD, FRCSC Shahin Kayum MD, MRCS Ryan M. Khan PA Anastasia Sanjevic |
container_volume |
4 |
class |
RD701-811 |
format_se |
Elektronische Aufsätze |
author-letter |
Timothy R. Daniels MD, FRCSC |
doi_str_mv |
10.1177/2473011419S00156 |
author2-role |
verfasserin |
title_sort |
two-year outcomes of total ankle replacement with the cadence total ankle replacement system |
callnumber |
RD701-811 |
title_auth |
Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
abstract |
Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). |
abstractGer |
Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). |
abstract_unstemmed |
Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus). |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_73 GBV_ILN_74 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_374 GBV_ILN_602 GBV_ILN_2014 GBV_ILN_2034 GBV_ILN_2068 GBV_ILN_2704 GBV_ILN_2707 GBV_ILN_2890 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
title_short |
Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System |
url |
https://doi.org/10.1177/2473011419S00156 https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab https://doaj.org/toc/2473-0114 |
remote_bool |
true |
author2 |
Shahin Kayum MD, MRCS Ryan M. Khan PA Anastasia Sanjevic |
author2Str |
Shahin Kayum MD, MRCS Ryan M. Khan PA Anastasia Sanjevic |
ppnlink |
872473007 |
callnumber-subject |
RD - Surgery |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.1177/2473011419S00156 |
callnumber-a |
RD701-811 |
up_date |
2024-07-03T19:24:14.541Z |
_version_ |
1803587057923129344 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ053756746</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230308175400.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230227s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1177/2473011419S00156</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ053756746</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJfb310b0be2ab410d9758b5c91387daab</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="050" ind1=" " ind2="0"><subfield code="a">RD701-811</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Timothy R. Daniels MD, FRCSC</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Two-Year Outcomes of Total Ankle Replacement with the Cadence Total Ankle Replacement System</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Category: Ankle, Ankle Arthritis Introduction/Purpose: Over the last few decades, total ankle replacement (TAR) emerged as a reliable treatment option in end-stage ankle osteoarthritis (OA) while preserving motion and physiological load. The Cadence™ prosthesis, manufactured by Integra LifeSciences, is a two-component, fixed-bearing implant with minimal tibial and talar resection and has been in clinical use since June 2016. The purpose of this study is to assess the two-year validated clinical outcome scores and radiological parameters of the Cadence™ prosthesis at our hospital. Methods: Thirty-one consecutive patients who received the Cadence™ prosthesis between June 2016 and December 31st, 2016 were enrolled. All patients who underwent a primary TAR with the Cadence™ prosthesis and who had at least two years follow- up were included. All surgeries were performed by a single surgeon with experience in total ankle arthroplasty. At the yearly clinical evaluation, patients were administered the Ankle Osteoarthritis Scale (AOS) and the Short Form Health Survey (SF-36), and their radiological outcomes pre and post-surgery were assessed. Results: Thirty-one patients fulfilled the inclusion criteria. Forty ancillary procedures were performed on twenty-four TAR’s. Radiological analyses showed preoperative talar sagittal translation with 25 anterior, 2 posterior, and 4 neutral. Sagittal translation decreased from an average 3.11 mm to 1.0 mm. Eleven ankles had a perioperative talar Varus and Valgus deformity that was corrected, with neutral alignment in all. At the two-year clinic visit, x-rays showed no lucencies or stress fractures and none of the ankles required revision of metal components. The pre and post-operative pain and disability scores displayed major improvement wherein AOS pain scores decreased -20.28 ± 14.34 points from an average of 47.86 points while AOS disability scores decreased -32.11 ± 22.70 from an average of 57.15 points. Conclusion: The overall outcome of the total ankle arthroplasty with the Cadence™ prosthesis showed excellent clinical and radiological outcomes. Compelling clinical evidence shows that the quality of life, functional measures, and pain in patients suffering from end-stage arthritis significantly improved following surgery with the Cadence™ total ankle replacement system. The semi- constrained design of this two-component implant and utilization of biased polyethylene inserts allowed for correction of the talus in both the sagittal (talar anterior / posterior translation) and coronal planes (talar varus / valgus).</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Orthopedic surgery</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Shahin Kayum MD, MRCS</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Ryan M. Khan PA</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Anastasia Sanjevic</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Foot & Ankle Orthopaedics</subfield><subfield code="d">SAGE Publishing, 2018</subfield><subfield code="g">4(2019)</subfield><subfield code="w">(DE-627)872473007</subfield><subfield code="w">(DE-600)2874570-X</subfield><subfield code="x">24730114</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:4</subfield><subfield code="g">year:2019</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1177/2473011419S00156</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/fb310b0be2ab410d9758b5c91387daab</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1177/2473011419S00156</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/2473-0114</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_374</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2704</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2707</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2890</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">4</subfield><subfield code="j">2019</subfield></datafield></record></collection>
|
score |
7.3998203 |