Micro-total envelope system with silicon nanowire separator for safe carcinogenic chemistry

Carcinogenic compounds present difficulties in synthesis not just during reaction but perhaps especially during purification. Here, the authors report a microfluidic device for the use of carcinogenic chloromethyl methyl ether that includes a silicon nanowire separator allowing isolated, automated p...
Ausführliche Beschreibung

Gespeichert in:
Autor*in:

Ajay K. Singh [verfasserIn]

Dong-Hyeon Ko [verfasserIn]

Niraj K. Vishwakarma [verfasserIn]

Seungwook Jang [verfasserIn]

Kyoung-Ik Min [verfasserIn]

Dong-Pyo Kim [verfasserIn]

Format:

E-Artikel

Sprache:

Englisch

Erschienen:

2016

Übergeordnetes Werk:

In: Nature Communications - Nature Portfolio, 2016, 7(2016), 1, Seite 7

Übergeordnetes Werk:

volume:7 ; year:2016 ; number:1 ; pages:7