Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels
This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is curren...
Ausführliche Beschreibung
Autor*in: |
Waldemar Kuczyński [verfasserIn] Marcin Kruzel [verfasserIn] Katarzyna Chliszcz [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2022 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
In: Energies - MDPI AG, 2008, 15(2022), 5, p 1789 |
---|---|
Übergeordnetes Werk: |
volume:15 ; year:2022 ; number:5, p 1789 |
Links: |
---|
DOI / URN: |
10.3390/en15051789 |
---|
Katalog-ID: |
DOAJ084606916 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ084606916 | ||
003 | DE-627 | ||
005 | 20240414181612.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230311s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/en15051789 |2 doi | |
035 | |a (DE-627)DOAJ084606916 | ||
035 | |a (DE-599)DOAJ8041ab9181804084b98ae63515367407 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 0 | |a Waldemar Kuczyński |e verfasserin |4 aut | |
245 | 1 | 0 | |a Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels |
264 | 1 | |c 2022 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. | ||
650 | 4 | |a phasechange | |
650 | 4 | |a minichannels | |
650 | 4 | |a impulsive instability | |
650 | 4 | |a zeotropic mixtures | |
653 | 0 | |a Technology | |
653 | 0 | |a T | |
700 | 0 | |a Marcin Kruzel |e verfasserin |4 aut | |
700 | 0 | |a Katarzyna Chliszcz |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t Energies |d MDPI AG, 2008 |g 15(2022), 5, p 1789 |w (DE-627)572083742 |w (DE-600)2437446-5 |x 19961073 |7 nnns |
773 | 1 | 8 | |g volume:15 |g year:2022 |g number:5, p 1789 |
856 | 4 | 0 | |u https://doi.org/10.3390/en15051789 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/8041ab9181804084b98ae63515367407 |z kostenfrei |
856 | 4 | 0 | |u https://www.mdpi.com/1996-1073/15/5/1789 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/1996-1073 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 15 |j 2022 |e 5, p 1789 |
author_variant |
w k wk m k mk k c kc |
---|---|
matchkey_str |
article:19961073:2022----::ersinoeodnmcusisaiiisuigodnainfetoiadzorpcergrnmx |
hierarchy_sort_str |
2022 |
publishDate |
2022 |
allfields |
10.3390/en15051789 doi (DE-627)DOAJ084606916 (DE-599)DOAJ8041ab9181804084b98ae63515367407 DE-627 ger DE-627 rakwb eng Waldemar Kuczyński verfasserin aut Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. phasechange minichannels impulsive instability zeotropic mixtures Technology T Marcin Kruzel verfasserin aut Katarzyna Chliszcz verfasserin aut In Energies MDPI AG, 2008 15(2022), 5, p 1789 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:15 year:2022 number:5, p 1789 https://doi.org/10.3390/en15051789 kostenfrei https://doaj.org/article/8041ab9181804084b98ae63515367407 kostenfrei https://www.mdpi.com/1996-1073/15/5/1789 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 15 2022 5, p 1789 |
spelling |
10.3390/en15051789 doi (DE-627)DOAJ084606916 (DE-599)DOAJ8041ab9181804084b98ae63515367407 DE-627 ger DE-627 rakwb eng Waldemar Kuczyński verfasserin aut Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. phasechange minichannels impulsive instability zeotropic mixtures Technology T Marcin Kruzel verfasserin aut Katarzyna Chliszcz verfasserin aut In Energies MDPI AG, 2008 15(2022), 5, p 1789 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:15 year:2022 number:5, p 1789 https://doi.org/10.3390/en15051789 kostenfrei https://doaj.org/article/8041ab9181804084b98ae63515367407 kostenfrei https://www.mdpi.com/1996-1073/15/5/1789 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 15 2022 5, p 1789 |
allfields_unstemmed |
10.3390/en15051789 doi (DE-627)DOAJ084606916 (DE-599)DOAJ8041ab9181804084b98ae63515367407 DE-627 ger DE-627 rakwb eng Waldemar Kuczyński verfasserin aut Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. phasechange minichannels impulsive instability zeotropic mixtures Technology T Marcin Kruzel verfasserin aut Katarzyna Chliszcz verfasserin aut In Energies MDPI AG, 2008 15(2022), 5, p 1789 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:15 year:2022 number:5, p 1789 https://doi.org/10.3390/en15051789 kostenfrei https://doaj.org/article/8041ab9181804084b98ae63515367407 kostenfrei https://www.mdpi.com/1996-1073/15/5/1789 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 15 2022 5, p 1789 |
allfieldsGer |
10.3390/en15051789 doi (DE-627)DOAJ084606916 (DE-599)DOAJ8041ab9181804084b98ae63515367407 DE-627 ger DE-627 rakwb eng Waldemar Kuczyński verfasserin aut Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. phasechange minichannels impulsive instability zeotropic mixtures Technology T Marcin Kruzel verfasserin aut Katarzyna Chliszcz verfasserin aut In Energies MDPI AG, 2008 15(2022), 5, p 1789 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:15 year:2022 number:5, p 1789 https://doi.org/10.3390/en15051789 kostenfrei https://doaj.org/article/8041ab9181804084b98ae63515367407 kostenfrei https://www.mdpi.com/1996-1073/15/5/1789 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 15 2022 5, p 1789 |
allfieldsSound |
10.3390/en15051789 doi (DE-627)DOAJ084606916 (DE-599)DOAJ8041ab9181804084b98ae63515367407 DE-627 ger DE-627 rakwb eng Waldemar Kuczyński verfasserin aut Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels 2022 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. phasechange minichannels impulsive instability zeotropic mixtures Technology T Marcin Kruzel verfasserin aut Katarzyna Chliszcz verfasserin aut In Energies MDPI AG, 2008 15(2022), 5, p 1789 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:15 year:2022 number:5, p 1789 https://doi.org/10.3390/en15051789 kostenfrei https://doaj.org/article/8041ab9181804084b98ae63515367407 kostenfrei https://www.mdpi.com/1996-1073/15/5/1789 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 15 2022 5, p 1789 |
language |
English |
source |
In Energies 15(2022), 5, p 1789 volume:15 year:2022 number:5, p 1789 |
sourceStr |
In Energies 15(2022), 5, p 1789 volume:15 year:2022 number:5, p 1789 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
phasechange minichannels impulsive instability zeotropic mixtures Technology T |
isfreeaccess_bool |
true |
container_title |
Energies |
authorswithroles_txt_mv |
Waldemar Kuczyński @@aut@@ Marcin Kruzel @@aut@@ Katarzyna Chliszcz @@aut@@ |
publishDateDaySort_date |
2022-01-01T00:00:00Z |
hierarchy_top_id |
572083742 |
id |
DOAJ084606916 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ084606916</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20240414181612.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230311s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3390/en15051789</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ084606916</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ8041ab9181804084b98ae63515367407</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Waldemar Kuczyński</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">phasechange</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">minichannels</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">impulsive instability</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">zeotropic mixtures</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Technology</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">T</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Marcin Kruzel</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Katarzyna Chliszcz</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Energies</subfield><subfield code="d">MDPI AG, 2008</subfield><subfield code="g">15(2022), 5, p 1789</subfield><subfield code="w">(DE-627)572083742</subfield><subfield code="w">(DE-600)2437446-5</subfield><subfield code="x">19961073</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:15</subfield><subfield code="g">year:2022</subfield><subfield code="g">number:5, p 1789</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3390/en15051789</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/8041ab9181804084b98ae63515367407</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://www.mdpi.com/1996-1073/15/5/1789</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/1996-1073</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">15</subfield><subfield code="j">2022</subfield><subfield code="e">5, p 1789</subfield></datafield></record></collection>
|
author |
Waldemar Kuczyński |
spellingShingle |
Waldemar Kuczyński misc phasechange misc minichannels misc impulsive instability misc zeotropic mixtures misc Technology misc T Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels |
authorStr |
Waldemar Kuczyński |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)572083742 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut |
collection |
DOAJ |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
19961073 |
topic_title |
Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels phasechange minichannels impulsive instability zeotropic mixtures |
topic |
misc phasechange misc minichannels misc impulsive instability misc zeotropic mixtures misc Technology misc T |
topic_unstemmed |
misc phasechange misc minichannels misc impulsive instability misc zeotropic mixtures misc Technology misc T |
topic_browse |
misc phasechange misc minichannels misc impulsive instability misc zeotropic mixtures misc Technology misc T |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Energies |
hierarchy_parent_id |
572083742 |
hierarchy_top_title |
Energies |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)572083742 (DE-600)2437446-5 |
title |
Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels |
ctrlnum |
(DE-627)DOAJ084606916 (DE-599)DOAJ8041ab9181804084b98ae63515367407 |
title_full |
Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels |
author_sort |
Waldemar Kuczyński |
journal |
Energies |
journalStr |
Energies |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2022 |
contenttype_str_mv |
txt |
author_browse |
Waldemar Kuczyński Marcin Kruzel Katarzyna Chliszcz |
container_volume |
15 |
format_se |
Elektronische Aufsätze |
author-letter |
Waldemar Kuczyński |
doi_str_mv |
10.3390/en15051789 |
author2-role |
verfasserin |
title_sort |
regression model of dynamic pulse instabilities during condensation of zeotropic and azeotropic refrigerant mixtures r404a, r448a and r507a in minichannels |
title_auth |
Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels |
abstract |
This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. |
abstractGer |
This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. |
abstract_unstemmed |
This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
5, p 1789 |
title_short |
Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels |
url |
https://doi.org/10.3390/en15051789 https://doaj.org/article/8041ab9181804084b98ae63515367407 https://www.mdpi.com/1996-1073/15/5/1789 https://doaj.org/toc/1996-1073 |
remote_bool |
true |
author2 |
Marcin Kruzel Katarzyna Chliszcz |
author2Str |
Marcin Kruzel Katarzyna Chliszcz |
ppnlink |
572083742 |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.3390/en15051789 |
up_date |
2024-07-03T23:47:55.718Z |
_version_ |
1803603647628574720 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ084606916</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20240414181612.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230311s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3390/en15051789</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ084606916</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ8041ab9181804084b98ae63515367407</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Waldemar Kuczyński</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Regression Model of Dynamic Pulse Instabilities during Condensation of Zeotropic and Azeotropic Refrigerant Mixtures R404A, R448A and R507A in Minichannels</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This paper presents experimental research and mathematical modeling data concerning the impact of unit dynamic instabilities on the phase-transition condensation processes of the zeotropic mixtures R404A and R448A and azeotropic R507A refrigerants in pipe minichannels. The R507 refrigerant is currently used as a temporary substitute for R404A, whereas R448A is a sustainable prospective substitute for R404A. The study presents experimental testing data for the condensation processes of these refrigerants in pipe minichannels and a proposal for the use of dimensional analysis, including the Π-Buckingham theorem, to determine the regression relationship explaining the propagation of unit dynamic instabilities. Based on the experimental studies performed, regression computational models were developed and showed satisfactory agreement in the range of 20% to 25%. They give the possibility to identify, in a utilitarian, way the speed of propagation of temperature and pressure instabilities during the liquefaction of refrigerants. The study was carried out on pipe minichannels with an internal diameter of di = 3.3, 2.3, 1.92, 1.44 and 1.40 mm.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">phasechange</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">minichannels</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">impulsive instability</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">zeotropic mixtures</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Technology</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">T</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Marcin Kruzel</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Katarzyna Chliszcz</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Energies</subfield><subfield code="d">MDPI AG, 2008</subfield><subfield code="g">15(2022), 5, p 1789</subfield><subfield code="w">(DE-627)572083742</subfield><subfield code="w">(DE-600)2437446-5</subfield><subfield code="x">19961073</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:15</subfield><subfield code="g">year:2022</subfield><subfield code="g">number:5, p 1789</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3390/en15051789</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/8041ab9181804084b98ae63515367407</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://www.mdpi.com/1996-1073/15/5/1789</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/1996-1073</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">15</subfield><subfield code="j">2022</subfield><subfield code="e">5, p 1789</subfield></datafield></record></collection>
|
score |
7.4005327 |