Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine
The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation...
Ausführliche Beschreibung
Autor*in: |
Narender Singh [verfasserIn] Dibakor Boruah [verfasserIn] Jeroen D. M. De Kooning [verfasserIn] Wim De Waele [verfasserIn] Lieven Vandevelde [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2023 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
In: Energies - MDPI AG, 2008, 16(2023), 6, p 2851 |
---|---|
Übergeordnetes Werk: |
volume:16 ; year:2023 ; number:6, p 2851 |
Links: |
---|
DOI / URN: |
10.3390/en16062851 |
---|
Katalog-ID: |
DOAJ087377888 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | DOAJ087377888 | ||
003 | DE-627 | ||
005 | 20240413051825.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230331s2023 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.3390/en16062851 |2 doi | |
035 | |a (DE-627)DOAJ087377888 | ||
035 | |a (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
100 | 0 | |a Narender Singh |e verfasserin |4 aut | |
245 | 1 | 0 | |a Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine |
264 | 1 | |c 2023 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. | ||
650 | 4 | |a frequency containment reserve | |
650 | 4 | |a structural loading | |
650 | 4 | |a wind energy | |
650 | 4 | |a wind turbine control | |
650 | 4 | |a wind turbine main bearing | |
653 | 0 | |a Technology | |
653 | 0 | |a T | |
700 | 0 | |a Dibakor Boruah |e verfasserin |4 aut | |
700 | 0 | |a Jeroen D. M. De Kooning |e verfasserin |4 aut | |
700 | 0 | |a Wim De Waele |e verfasserin |4 aut | |
700 | 0 | |a Lieven Vandevelde |e verfasserin |4 aut | |
773 | 0 | 8 | |i In |t Energies |d MDPI AG, 2008 |g 16(2023), 6, p 2851 |w (DE-627)572083742 |w (DE-600)2437446-5 |x 19961073 |7 nnns |
773 | 1 | 8 | |g volume:16 |g year:2023 |g number:6, p 2851 |
856 | 4 | 0 | |u https://doi.org/10.3390/en16062851 |z kostenfrei |
856 | 4 | 0 | |u https://doaj.org/article/221b069473a74cb781d7b36d9d996328 |z kostenfrei |
856 | 4 | 0 | |u https://www.mdpi.com/1996-1073/16/6/2851 |z kostenfrei |
856 | 4 | 2 | |u https://doaj.org/toc/1996-1073 |y Journal toc |z kostenfrei |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_DOAJ | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_39 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_161 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_206 | ||
912 | |a GBV_ILN_213 | ||
912 | |a GBV_ILN_230 | ||
912 | |a GBV_ILN_285 | ||
912 | |a GBV_ILN_293 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2009 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2055 | ||
912 | |a GBV_ILN_2108 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2119 | ||
912 | |a GBV_ILN_4012 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4249 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4307 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4367 | ||
912 | |a GBV_ILN_4700 | ||
951 | |a AR | ||
952 | |d 16 |j 2023 |e 6, p 2851 |
author_variant |
n s ns d b db j d m d k jdmdk w d w wdw l v lv |
---|---|
matchkey_str |
article:19961073:2023----::matsesetfyailaignuebtervsoofeunyotimnrsrenhmi |
hierarchy_sort_str |
2023 |
publishDate |
2023 |
allfields |
10.3390/en16062851 doi (DE-627)DOAJ087377888 (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 DE-627 ger DE-627 rakwb eng Narender Singh verfasserin aut Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine 2023 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing Technology T Dibakor Boruah verfasserin aut Jeroen D. M. De Kooning verfasserin aut Wim De Waele verfasserin aut Lieven Vandevelde verfasserin aut In Energies MDPI AG, 2008 16(2023), 6, p 2851 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:16 year:2023 number:6, p 2851 https://doi.org/10.3390/en16062851 kostenfrei https://doaj.org/article/221b069473a74cb781d7b36d9d996328 kostenfrei https://www.mdpi.com/1996-1073/16/6/2851 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 16 2023 6, p 2851 |
spelling |
10.3390/en16062851 doi (DE-627)DOAJ087377888 (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 DE-627 ger DE-627 rakwb eng Narender Singh verfasserin aut Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine 2023 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing Technology T Dibakor Boruah verfasserin aut Jeroen D. M. De Kooning verfasserin aut Wim De Waele verfasserin aut Lieven Vandevelde verfasserin aut In Energies MDPI AG, 2008 16(2023), 6, p 2851 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:16 year:2023 number:6, p 2851 https://doi.org/10.3390/en16062851 kostenfrei https://doaj.org/article/221b069473a74cb781d7b36d9d996328 kostenfrei https://www.mdpi.com/1996-1073/16/6/2851 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 16 2023 6, p 2851 |
allfields_unstemmed |
10.3390/en16062851 doi (DE-627)DOAJ087377888 (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 DE-627 ger DE-627 rakwb eng Narender Singh verfasserin aut Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine 2023 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing Technology T Dibakor Boruah verfasserin aut Jeroen D. M. De Kooning verfasserin aut Wim De Waele verfasserin aut Lieven Vandevelde verfasserin aut In Energies MDPI AG, 2008 16(2023), 6, p 2851 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:16 year:2023 number:6, p 2851 https://doi.org/10.3390/en16062851 kostenfrei https://doaj.org/article/221b069473a74cb781d7b36d9d996328 kostenfrei https://www.mdpi.com/1996-1073/16/6/2851 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 16 2023 6, p 2851 |
allfieldsGer |
10.3390/en16062851 doi (DE-627)DOAJ087377888 (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 DE-627 ger DE-627 rakwb eng Narender Singh verfasserin aut Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine 2023 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing Technology T Dibakor Boruah verfasserin aut Jeroen D. M. De Kooning verfasserin aut Wim De Waele verfasserin aut Lieven Vandevelde verfasserin aut In Energies MDPI AG, 2008 16(2023), 6, p 2851 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:16 year:2023 number:6, p 2851 https://doi.org/10.3390/en16062851 kostenfrei https://doaj.org/article/221b069473a74cb781d7b36d9d996328 kostenfrei https://www.mdpi.com/1996-1073/16/6/2851 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 16 2023 6, p 2851 |
allfieldsSound |
10.3390/en16062851 doi (DE-627)DOAJ087377888 (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 DE-627 ger DE-627 rakwb eng Narender Singh verfasserin aut Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine 2023 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing Technology T Dibakor Boruah verfasserin aut Jeroen D. M. De Kooning verfasserin aut Wim De Waele verfasserin aut Lieven Vandevelde verfasserin aut In Energies MDPI AG, 2008 16(2023), 6, p 2851 (DE-627)572083742 (DE-600)2437446-5 19961073 nnns volume:16 year:2023 number:6, p 2851 https://doi.org/10.3390/en16062851 kostenfrei https://doaj.org/article/221b069473a74cb781d7b36d9d996328 kostenfrei https://www.mdpi.com/1996-1073/16/6/2851 kostenfrei https://doaj.org/toc/1996-1073 Journal toc kostenfrei GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 AR 16 2023 6, p 2851 |
language |
English |
source |
In Energies 16(2023), 6, p 2851 volume:16 year:2023 number:6, p 2851 |
sourceStr |
In Energies 16(2023), 6, p 2851 volume:16 year:2023 number:6, p 2851 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing Technology T |
isfreeaccess_bool |
true |
container_title |
Energies |
authorswithroles_txt_mv |
Narender Singh @@aut@@ Dibakor Boruah @@aut@@ Jeroen D. M. De Kooning @@aut@@ Wim De Waele @@aut@@ Lieven Vandevelde @@aut@@ |
publishDateDaySort_date |
2023-01-01T00:00:00Z |
hierarchy_top_id |
572083742 |
id |
DOAJ087377888 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ087377888</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20240413051825.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230331s2023 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3390/en16062851</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ087377888</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ221b069473a74cb781d7b36d9d996328</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Narender Singh</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2023</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">frequency containment reserve</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">structural loading</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">wind energy</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">wind turbine control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">wind turbine main bearing</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Technology</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">T</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Dibakor Boruah</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Jeroen D. M. De Kooning</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Wim De Waele</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Lieven Vandevelde</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Energies</subfield><subfield code="d">MDPI AG, 2008</subfield><subfield code="g">16(2023), 6, p 2851</subfield><subfield code="w">(DE-627)572083742</subfield><subfield code="w">(DE-600)2437446-5</subfield><subfield code="x">19961073</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:16</subfield><subfield code="g">year:2023</subfield><subfield code="g">number:6, p 2851</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3390/en16062851</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/221b069473a74cb781d7b36d9d996328</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://www.mdpi.com/1996-1073/16/6/2851</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/1996-1073</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">16</subfield><subfield code="j">2023</subfield><subfield code="e">6, p 2851</subfield></datafield></record></collection>
|
author |
Narender Singh |
spellingShingle |
Narender Singh misc frequency containment reserve misc structural loading misc wind energy misc wind turbine control misc wind turbine main bearing misc Technology misc T Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine |
authorStr |
Narender Singh |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)572083742 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut |
collection |
DOAJ |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
19961073 |
topic_title |
Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine frequency containment reserve structural loading wind energy wind turbine control wind turbine main bearing |
topic |
misc frequency containment reserve misc structural loading misc wind energy misc wind turbine control misc wind turbine main bearing misc Technology misc T |
topic_unstemmed |
misc frequency containment reserve misc structural loading misc wind energy misc wind turbine control misc wind turbine main bearing misc Technology misc T |
topic_browse |
misc frequency containment reserve misc structural loading misc wind energy misc wind turbine control misc wind turbine main bearing misc Technology misc T |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Energies |
hierarchy_parent_id |
572083742 |
hierarchy_top_title |
Energies |
isfreeaccess_txt |
true |
familylinks_str_mv |
(DE-627)572083742 (DE-600)2437446-5 |
title |
Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine |
ctrlnum |
(DE-627)DOAJ087377888 (DE-599)DOAJ221b069473a74cb781d7b36d9d996328 |
title_full |
Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine |
author_sort |
Narender Singh |
journal |
Energies |
journalStr |
Energies |
lang_code |
eng |
isOA_bool |
true |
recordtype |
marc |
publishDateSort |
2023 |
contenttype_str_mv |
txt |
author_browse |
Narender Singh Dibakor Boruah Jeroen D. M. De Kooning Wim De Waele Lieven Vandevelde |
container_volume |
16 |
format_se |
Elektronische Aufsätze |
author-letter |
Narender Singh |
doi_str_mv |
10.3390/en16062851 |
author2-role |
verfasserin |
title_sort |
impact assessment of dynamic loading induced by the provision of frequency containment reserve on the main bearing lifetime of a wind turbine |
title_auth |
Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine |
abstract |
The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. |
abstractGer |
The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. |
abstract_unstemmed |
The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_DOAJ GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_39 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_95 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_161 GBV_ILN_170 GBV_ILN_206 GBV_ILN_213 GBV_ILN_230 GBV_ILN_285 GBV_ILN_293 GBV_ILN_370 GBV_ILN_602 GBV_ILN_2005 GBV_ILN_2009 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2055 GBV_ILN_2108 GBV_ILN_2111 GBV_ILN_2119 GBV_ILN_4012 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4249 GBV_ILN_4305 GBV_ILN_4306 GBV_ILN_4307 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4367 GBV_ILN_4700 |
container_issue |
6, p 2851 |
title_short |
Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine |
url |
https://doi.org/10.3390/en16062851 https://doaj.org/article/221b069473a74cb781d7b36d9d996328 https://www.mdpi.com/1996-1073/16/6/2851 https://doaj.org/toc/1996-1073 |
remote_bool |
true |
author2 |
Dibakor Boruah Jeroen D. M. De Kooning Wim De Waele Lieven Vandevelde |
author2Str |
Dibakor Boruah Jeroen D. M. De Kooning Wim De Waele Lieven Vandevelde |
ppnlink |
572083742 |
mediatype_str_mv |
c |
isOA_txt |
true |
hochschulschrift_bool |
false |
doi_str |
10.3390/en16062851 |
up_date |
2024-07-04T01:26:16.365Z |
_version_ |
1803609834906451968 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">DOAJ087377888</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20240413051825.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230331s2023 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3390/en16062851</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)DOAJ087377888</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)DOAJ221b069473a74cb781d7b36d9d996328</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="0" ind2=" "><subfield code="a">Narender Singh</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Impact Assessment of Dynamic Loading Induced by the Provision of Frequency Containment Reserve on the Main Bearing Lifetime of a Wind Turbine</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2023</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The components of an operational wind turbine are continuously impacted by both static and dynamic loads. Regular inspections and maintenance are required to keep these components healthy. The main bearing of a wind turbine is one such component that experiences heavy loading forces during operation. These forces depend on various parameters such as wind speed, operating regime and control actions. When a wind turbine provides frequency containment reserve (FCR) to support the grid frequency, the forces acting upon the main bearing are also expected to exhibit more dynamic variations. These forces have a direct impact on the lifetime of the main bearing. With an increasing trend of wind turbines participating in the frequency ancillary services market, an analysis of these dynamic forces becomes necessary. To this end, this paper assesses the effect of FCR-based control on the main bearing lifetime of the wind turbine. Firstly, a control algorithm is implemented such that the output power of the wind turbine is regulated as a function of grid frequency and the amount of FCR. Simulations are performed for a range of FCR to study the changing behaviour of dynamical forces acting on the main bearing with respect to the amount of FCR provided. Then, based on the outputs from these simulations and using 2 years of LiDAR wind data, the lifetime of the main bearing of the wind turbine is calculated and compared for each of the cases. Finally, based on the results obtained from this study, the impact of FCR provision on the main bearing lifetime is quantified and recommendations are made, that could be taken into account in the operation strategy of a wind farm.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">frequency containment reserve</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">structural loading</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">wind energy</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">wind turbine control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">wind turbine main bearing</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">Technology</subfield></datafield><datafield tag="653" ind1=" " ind2="0"><subfield code="a">T</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Dibakor Boruah</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Jeroen D. M. De Kooning</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Wim De Waele</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="0" ind2=" "><subfield code="a">Lieven Vandevelde</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Energies</subfield><subfield code="d">MDPI AG, 2008</subfield><subfield code="g">16(2023), 6, p 2851</subfield><subfield code="w">(DE-627)572083742</subfield><subfield code="w">(DE-600)2437446-5</subfield><subfield code="x">19961073</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:16</subfield><subfield code="g">year:2023</subfield><subfield code="g">number:6, p 2851</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.3390/en16062851</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doaj.org/article/221b069473a74cb781d7b36d9d996328</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://www.mdpi.com/1996-1073/16/6/2851</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">https://doaj.org/toc/1996-1073</subfield><subfield code="y">Journal toc</subfield><subfield code="z">kostenfrei</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_DOAJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_39</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_161</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_206</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_213</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_230</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_285</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_293</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2009</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2055</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2108</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2119</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4012</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4249</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4307</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4367</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4700</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">16</subfield><subfield code="j">2023</subfield><subfield code="e">6, p 2851</subfield></datafield></record></collection>
|
score |
7.4008827 |