Improved beam diagnostics and optimization at ISAC via TITAN’s MR-TOF-MS

Determination of the constituents of the radioactive ion beam (RIB) is crucial for successful experiments at low-energy RIB facilities and as such decides the fate of many experiments. Here we present the role of TITAN’s Multiple-Reflection Time-Of-Flight Mass Separator (MR-TOF-MS) and how it comple...
Ausführliche Beschreibung

Gespeichert in:
Autor*in:

Reiter, M.P. [verfasserIn]

Ames, F. [verfasserIn]

Andreoiu, C. [verfasserIn]

Ayet San Andrés, S. [verfasserIn]

Babcock, C. [verfasserIn]

Barquest, B.R. [verfasserIn]

Bergmann, J. [verfasserIn]

Bollig, J. [verfasserIn]

Brunner, T. [verfasserIn]

Dickel, T. [verfasserIn]

Dilling, J. [verfasserIn]

Dillmann, I. [verfasserIn]

Dunling, E. [verfasserIn]

Finlay, A. [verfasserIn]

Gwinner, G. [verfasserIn]

Graham, L. [verfasserIn]

Hornung, C. [verfasserIn]

Kootte, B. [verfasserIn]

Klawitter, R. [verfasserIn]

Kunz, P. [verfasserIn]

Lan, Y. [verfasserIn]

Lascar, D. [verfasserIn]

Lassen, J. [verfasserIn]

Leistenschneider, E. [verfasserIn]

Li, R. [verfasserIn]

McKay, J.E. [verfasserIn]

Mostamand, M. [verfasserIn]

Paul, S.F. [verfasserIn]

Plaß, W.R. [verfasserIn]

Scheidenberger, C. [verfasserIn]

Schultz, B.E. [verfasserIn]

Steinbrügge, R. [verfasserIn]

Teigelhoefer, A. [verfasserIn]

Thompson, R. [verfasserIn]

Wieser, M.E. [verfasserIn]

Will, C. [verfasserIn]

Kwiatkowski, A.A. [verfasserIn]

Format:

E-Artikel

Sprache:

Englisch

Erschienen:

2019

Schlagwörter:

Low-energy RIB

Isotopic separation on line

Beam purification and optimization

MR-TOF-MS

Übergeordnetes Werk:

Enthalten in: Nuclear instruments & methods in physics research / B - Amsterdam [u.a.] : Elsevier, 1984, 463, Seite 431-436

Übergeordnetes Werk:

volume:463 ; pages:431-436

DOI / URN:

10.1016/j.nimb.2019.04.034

Katalog-ID:

ELV003368793

Nicht das Richtige dabei?

Schreiben Sie uns!