Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals
Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.A...
Ausführliche Beschreibung
Autor*in: |
de Miranda Costa, M.M. [verfasserIn] Santana, H.T. [verfasserIn] Saturno Hernandez, P.J. [verfasserIn] Carvalho, A.A. [verfasserIn] da Silva Gama, Z.A. [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2020 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: The journal of hospital infection - Kidlington [u.a.] : Elsevier, 1980, 105, Seite 24-34 |
---|---|
Übergeordnetes Werk: |
volume:105 ; pages:24-34 |
DOI / URN: |
10.1016/j.jhin.2020.03.005 |
---|
Katalog-ID: |
ELV004059646 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV004059646 | ||
003 | DE-627 | ||
005 | 20230524161722.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230502s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jhin.2020.03.005 |2 doi | |
035 | |a (DE-627)ELV004059646 | ||
035 | |a (ELSEVIER)S0195-6701(20)30104-3 | ||
040 | |a DE-627 |b ger |c DE-627 |e rda | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q DE-600 |
084 | |a 44.17 |2 bkl | ||
084 | |a 44.11 |2 bkl | ||
100 | 1 | |a de Miranda Costa, M.M. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals |
264 | 1 | |c 2020 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. | ||
650 | 4 | |a Quality improvement | |
650 | 4 | |a Patient safety | |
650 | 4 | |a Infection control | |
650 | 4 | |a Health services research | |
700 | 1 | |a Santana, H.T. |e verfasserin |4 aut | |
700 | 1 | |a Saturno Hernandez, P.J. |e verfasserin |4 aut | |
700 | 1 | |a Carvalho, A.A. |e verfasserin |4 aut | |
700 | 1 | |a da Silva Gama, Z.A. |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t The journal of hospital infection |d Kidlington [u.a.] : Elsevier, 1980 |g 105, Seite 24-34 |h Online-Ressource |w (DE-627)32041986X |w (DE-600)2002429-0 |w (DE-576)104344709 |x 1532-2939 |7 nnns |
773 | 1 | 8 | |g volume:105 |g pages:24-34 |
912 | |a GBV_USEFLAG_U | ||
912 | |a SYSFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
936 | b | k | |a 44.17 |j Stationäres Gesundheitswesen |j Krankenhauswesen |
936 | b | k | |a 44.11 |j Präventivmedizin |
951 | |a AR | ||
952 | |d 105 |h 24-34 |
author_variant |
m c m d mcm mcmd h s hs h p s hp hps a c ac s g z d sgz sgzd |
---|---|
matchkey_str |
article:15322939:2020----::eutoaainlytmieultipoeetntaieotemlmnainfvdneaeifcinr |
hierarchy_sort_str |
2020 |
bklnumber |
44.17 44.11 |
publishDate |
2020 |
allfields |
10.1016/j.jhin.2020.03.005 doi (DE-627)ELV004059646 (ELSEVIER)S0195-6701(20)30104-3 DE-627 ger DE-627 rda eng 610 DE-600 44.17 bkl 44.11 bkl de Miranda Costa, M.M. verfasserin aut Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. Quality improvement Patient safety Infection control Health services research Santana, H.T. verfasserin aut Saturno Hernandez, P.J. verfasserin aut Carvalho, A.A. verfasserin aut da Silva Gama, Z.A. verfasserin aut Enthalten in The journal of hospital infection Kidlington [u.a.] : Elsevier, 1980 105, Seite 24-34 Online-Ressource (DE-627)32041986X (DE-600)2002429-0 (DE-576)104344709 1532-2939 nnns volume:105 pages:24-34 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.17 Stationäres Gesundheitswesen Krankenhauswesen 44.11 Präventivmedizin AR 105 24-34 |
spelling |
10.1016/j.jhin.2020.03.005 doi (DE-627)ELV004059646 (ELSEVIER)S0195-6701(20)30104-3 DE-627 ger DE-627 rda eng 610 DE-600 44.17 bkl 44.11 bkl de Miranda Costa, M.M. verfasserin aut Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. Quality improvement Patient safety Infection control Health services research Santana, H.T. verfasserin aut Saturno Hernandez, P.J. verfasserin aut Carvalho, A.A. verfasserin aut da Silva Gama, Z.A. verfasserin aut Enthalten in The journal of hospital infection Kidlington [u.a.] : Elsevier, 1980 105, Seite 24-34 Online-Ressource (DE-627)32041986X (DE-600)2002429-0 (DE-576)104344709 1532-2939 nnns volume:105 pages:24-34 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.17 Stationäres Gesundheitswesen Krankenhauswesen 44.11 Präventivmedizin AR 105 24-34 |
allfields_unstemmed |
10.1016/j.jhin.2020.03.005 doi (DE-627)ELV004059646 (ELSEVIER)S0195-6701(20)30104-3 DE-627 ger DE-627 rda eng 610 DE-600 44.17 bkl 44.11 bkl de Miranda Costa, M.M. verfasserin aut Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. Quality improvement Patient safety Infection control Health services research Santana, H.T. verfasserin aut Saturno Hernandez, P.J. verfasserin aut Carvalho, A.A. verfasserin aut da Silva Gama, Z.A. verfasserin aut Enthalten in The journal of hospital infection Kidlington [u.a.] : Elsevier, 1980 105, Seite 24-34 Online-Ressource (DE-627)32041986X (DE-600)2002429-0 (DE-576)104344709 1532-2939 nnns volume:105 pages:24-34 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.17 Stationäres Gesundheitswesen Krankenhauswesen 44.11 Präventivmedizin AR 105 24-34 |
allfieldsGer |
10.1016/j.jhin.2020.03.005 doi (DE-627)ELV004059646 (ELSEVIER)S0195-6701(20)30104-3 DE-627 ger DE-627 rda eng 610 DE-600 44.17 bkl 44.11 bkl de Miranda Costa, M.M. verfasserin aut Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. Quality improvement Patient safety Infection control Health services research Santana, H.T. verfasserin aut Saturno Hernandez, P.J. verfasserin aut Carvalho, A.A. verfasserin aut da Silva Gama, Z.A. verfasserin aut Enthalten in The journal of hospital infection Kidlington [u.a.] : Elsevier, 1980 105, Seite 24-34 Online-Ressource (DE-627)32041986X (DE-600)2002429-0 (DE-576)104344709 1532-2939 nnns volume:105 pages:24-34 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.17 Stationäres Gesundheitswesen Krankenhauswesen 44.11 Präventivmedizin AR 105 24-34 |
allfieldsSound |
10.1016/j.jhin.2020.03.005 doi (DE-627)ELV004059646 (ELSEVIER)S0195-6701(20)30104-3 DE-627 ger DE-627 rda eng 610 DE-600 44.17 bkl 44.11 bkl de Miranda Costa, M.M. verfasserin aut Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. Quality improvement Patient safety Infection control Health services research Santana, H.T. verfasserin aut Saturno Hernandez, P.J. verfasserin aut Carvalho, A.A. verfasserin aut da Silva Gama, Z.A. verfasserin aut Enthalten in The journal of hospital infection Kidlington [u.a.] : Elsevier, 1980 105, Seite 24-34 Online-Ressource (DE-627)32041986X (DE-600)2002429-0 (DE-576)104344709 1532-2939 nnns volume:105 pages:24-34 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.17 Stationäres Gesundheitswesen Krankenhauswesen 44.11 Präventivmedizin AR 105 24-34 |
language |
English |
source |
Enthalten in The journal of hospital infection 105, Seite 24-34 volume:105 pages:24-34 |
sourceStr |
Enthalten in The journal of hospital infection 105, Seite 24-34 volume:105 pages:24-34 |
format_phy_str_mv |
Article |
bklname |
Stationäres Gesundheitswesen Krankenhauswesen Präventivmedizin |
institution |
findex.gbv.de |
topic_facet |
Quality improvement Patient safety Infection control Health services research |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
The journal of hospital infection |
authorswithroles_txt_mv |
de Miranda Costa, M.M. @@aut@@ Santana, H.T. @@aut@@ Saturno Hernandez, P.J. @@aut@@ Carvalho, A.A. @@aut@@ da Silva Gama, Z.A. @@aut@@ |
publishDateDaySort_date |
2020-01-01T00:00:00Z |
hierarchy_top_id |
32041986X |
dewey-sort |
3610 |
id |
ELV004059646 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV004059646</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230524161722.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230502s2020 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jhin.2020.03.005</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV004059646</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0195-6701(20)30104-3</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.17</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.11</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">de Miranda Costa, M.M.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2020</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Quality improvement</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Patient safety</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Infection control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Health services research</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Santana, H.T.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Saturno Hernandez, P.J.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Carvalho, A.A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">da Silva Gama, Z.A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">The journal of hospital infection</subfield><subfield code="d">Kidlington [u.a.] : Elsevier, 1980</subfield><subfield code="g">105, Seite 24-34</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)32041986X</subfield><subfield code="w">(DE-600)2002429-0</subfield><subfield code="w">(DE-576)104344709</subfield><subfield code="x">1532-2939</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:105</subfield><subfield code="g">pages:24-34</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.17</subfield><subfield code="j">Stationäres Gesundheitswesen</subfield><subfield code="j">Krankenhauswesen</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.11</subfield><subfield code="j">Präventivmedizin</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">105</subfield><subfield code="h">24-34</subfield></datafield></record></collection>
|
author |
de Miranda Costa, M.M. |
spellingShingle |
de Miranda Costa, M.M. ddc 610 bkl 44.17 bkl 44.11 misc Quality improvement misc Patient safety misc Infection control misc Health services research Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals |
authorStr |
de Miranda Costa, M.M. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)32041986X |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1532-2939 |
topic_title |
610 DE-600 44.17 bkl 44.11 bkl Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals Quality improvement Patient safety Infection control Health services research |
topic |
ddc 610 bkl 44.17 bkl 44.11 misc Quality improvement misc Patient safety misc Infection control misc Health services research |
topic_unstemmed |
ddc 610 bkl 44.17 bkl 44.11 misc Quality improvement misc Patient safety misc Infection control misc Health services research |
topic_browse |
ddc 610 bkl 44.17 bkl 44.11 misc Quality improvement misc Patient safety misc Infection control misc Health services research |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
The journal of hospital infection |
hierarchy_parent_id |
32041986X |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
The journal of hospital infection |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)32041986X (DE-600)2002429-0 (DE-576)104344709 |
title |
Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals |
ctrlnum |
(DE-627)ELV004059646 (ELSEVIER)S0195-6701(20)30104-3 |
title_full |
Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals |
author_sort |
de Miranda Costa, M.M. |
journal |
The journal of hospital infection |
journalStr |
The journal of hospital infection |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2020 |
contenttype_str_mv |
zzz |
container_start_page |
24 |
author_browse |
de Miranda Costa, M.M. Santana, H.T. Saturno Hernandez, P.J. Carvalho, A.A. da Silva Gama, Z.A. |
container_volume |
105 |
class |
610 DE-600 44.17 bkl 44.11 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
de Miranda Costa, M.M. |
doi_str_mv |
10.1016/j.jhin.2020.03.005 |
dewey-full |
610 |
author2-role |
verfasserin |
title_sort |
results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in brazilian hospitals |
title_auth |
Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals |
abstract |
Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. |
abstractGer |
Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. |
abstract_unstemmed |
Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide. |
collection_details |
GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 |
title_short |
Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals |
remote_bool |
true |
author2 |
Santana, H.T. Saturno Hernandez, P.J. Carvalho, A.A. da Silva Gama, Z.A. |
author2Str |
Santana, H.T. Saturno Hernandez, P.J. Carvalho, A.A. da Silva Gama, Z.A. |
ppnlink |
32041986X |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1016/j.jhin.2020.03.005 |
up_date |
2024-07-06T21:42:42.672Z |
_version_ |
1803867560528052224 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV004059646</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230524161722.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230502s2020 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jhin.2020.03.005</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV004059646</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0195-6701(20)30104-3</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.17</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.11</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">de Miranda Costa, M.M.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Results of a national system-wide quality improvement initiative for the implementation of evidence-based infection prevention practices in Brazilian hospitals</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2020</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Background: Quality improvement (QI) methods are recommended to address healthcare-associated infections (HCAIs) in hospitals, but whereas internal initiatives have been widely studied, there is little evidence on the application and effect of a QI approach from an external system-wide perspective.Aim: To analyse the effect of a national system-wide QI initiative aimed at promoting HCAI prevention via regulatory interventions in Brazil.Methods: A QI cycle approach designed and assessed with a before-and-after quasi-experimental design was implemented by the Brazilian Health Regulatory Agency (ANVISA), targeting 1869 hospitals. Eleven evidence-based quality indicators related to HCAI prevention and a composite measure were assembled, shared, and assessed; the intervention to improve was then based on participatory multifaceted regulatory actions. Absolute and relative improvements were estimated after the intervention.Findings: In all, 563 hospitals (30.1% response) totalling 86,837 beds participated in the baseline assessment, and 681 hospitals (36.4% response) totalling 101,231 beds in the second. Ten of the 11 criteria improved (P < 0.05), as well as the composite indicator (P = 0.001) in all the regions of the country, particularly in the group of hospitals participating at baseline. ‘Hand hygiene (HH) infrastructure’ reached 100% (baseline: 97.9; P = 0.001), ‘HH protocol’ 96.9% (baseline: 92.9; P = 0.001), ‘HH monitoring’ 70% (baseline: 60.7; P < 0.001) and ‘existence of antimicrobial prescription protocol’ 80.7% (baseline: 73.2; P < 0.001), among others. The HCAI rates of the participating hospitals decreased after the intervention (P < 0.05).Conclusion: The QI cycle approach was useful in guiding system-wide interventions for patient safety. External regulation was feasible and effective in promoting internal HCAI prevention nationwide.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Quality improvement</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Patient safety</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Infection control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Health services research</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Santana, H.T.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Saturno Hernandez, P.J.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Carvalho, A.A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">da Silva Gama, Z.A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">The journal of hospital infection</subfield><subfield code="d">Kidlington [u.a.] : Elsevier, 1980</subfield><subfield code="g">105, Seite 24-34</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)32041986X</subfield><subfield code="w">(DE-600)2002429-0</subfield><subfield code="w">(DE-576)104344709</subfield><subfield code="x">1532-2939</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:105</subfield><subfield code="g">pages:24-34</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.17</subfield><subfield code="j">Stationäres Gesundheitswesen</subfield><subfield code="j">Krankenhauswesen</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.11</subfield><subfield code="j">Präventivmedizin</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">105</subfield><subfield code="h">24-34</subfield></datafield></record></collection>
|
score |
7.3995275 |