Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation
An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop incl...
Ausführliche Beschreibung
Autor*in: |
Li, Xiaoliang [verfasserIn] Wu, Linjie [verfasserIn] Lu, Sijia [verfasserIn] Yang, Heyun [verfasserIn] Xie, Wenzhou [verfasserIn] Zhao, Huiyan [verfasserIn] Zhang, Yaozhong [verfasserIn] Cao, Xin [verfasserIn] Tang, Gang [verfasserIn] Li, Hesheng [verfasserIn] Feng, Jiangtao [verfasserIn] Yan, Wei [verfasserIn] Zheng, Xing [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2020 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: Separation and purification technology - Amsterdam [u.a.] : Elsevier Science, 1997, 252 |
---|---|
Übergeordnetes Werk: |
volume:252 |
DOI / URN: |
10.1016/j.seppur.2020.117484 |
---|
Katalog-ID: |
ELV004550943 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV004550943 | ||
003 | DE-627 | ||
005 | 20230524135337.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230502s2020 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.seppur.2020.117484 |2 doi | |
035 | |a (DE-627)ELV004550943 | ||
035 | |a (ELSEVIER)S1383-5866(20)31958-4 | ||
040 | |a DE-627 |b ger |c DE-627 |e rda | ||
041 | |a eng | ||
082 | 0 | 4 | |a 540 |q DE-600 |
084 | |a 58.11 |2 bkl | ||
084 | |a 58.13 |2 bkl | ||
100 | 1 | |a Li, Xiaoliang |e verfasserin |4 aut | |
245 | 1 | 0 | |a Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation |
264 | 1 | |c 2020 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. | ||
650 | 4 | |a Cooling tower blowdown water | |
650 | 4 | |a Eco-friendly process | |
650 | 4 | |a Biodegradability | |
650 | 4 | |a Toxicity | |
650 | 4 | |a Transcriptional effect level index | |
700 | 1 | |a Wu, Linjie |e verfasserin |4 aut | |
700 | 1 | |a Lu, Sijia |e verfasserin |4 aut | |
700 | 1 | |a Yang, Heyun |e verfasserin |4 aut | |
700 | 1 | |a Xie, Wenzhou |e verfasserin |4 aut | |
700 | 1 | |a Zhao, Huiyan |e verfasserin |4 aut | |
700 | 1 | |a Zhang, Yaozhong |e verfasserin |4 aut | |
700 | 1 | |a Cao, Xin |e verfasserin |4 aut | |
700 | 1 | |a Tang, Gang |e verfasserin |4 aut | |
700 | 1 | |a Li, Hesheng |e verfasserin |4 aut | |
700 | 1 | |a Feng, Jiangtao |e verfasserin |4 aut | |
700 | 1 | |a Yan, Wei |e verfasserin |4 aut | |
700 | 1 | |a Zheng, Xing |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Separation and purification technology |d Amsterdam [u.a.] : Elsevier Science, 1997 |g 252 |h Online-Ressource |w (DE-627)320620123 |w (DE-600)2022535-0 |w (DE-576)259485349 |7 nnns |
773 | 1 | 8 | |g volume:252 |
912 | |a GBV_USEFLAG_U | ||
912 | |a SYSFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_150 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2006 | ||
912 | |a GBV_ILN_2008 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2088 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2470 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4322 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4325 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
936 | b | k | |a 58.11 |j Mechanische Verfahrenstechnik |
936 | b | k | |a 58.13 |j Thermische Verfahrenstechnik |
951 | |a AR | ||
952 | |d 252 |
author_variant |
x l xl l w lw s l sl h y hy w x wx h z hz y z yz x c xc g t gt h l hl j f jf w y wy x z xz |
---|---|
matchkey_str |
lixiaoliangwulinjielusijiayangheyunxiewe:2020----:ramnocoigoebodwwtrysnasrtoeetoaayioiainehiapromneoi |
hierarchy_sort_str |
2020 |
bklnumber |
58.11 58.13 |
publishDate |
2020 |
allfields |
10.1016/j.seppur.2020.117484 doi (DE-627)ELV004550943 (ELSEVIER)S1383-5866(20)31958-4 DE-627 ger DE-627 rda eng 540 DE-600 58.11 bkl 58.13 bkl Li, Xiaoliang verfasserin aut Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index Wu, Linjie verfasserin aut Lu, Sijia verfasserin aut Yang, Heyun verfasserin aut Xie, Wenzhou verfasserin aut Zhao, Huiyan verfasserin aut Zhang, Yaozhong verfasserin aut Cao, Xin verfasserin aut Tang, Gang verfasserin aut Li, Hesheng verfasserin aut Feng, Jiangtao verfasserin aut Yan, Wei verfasserin aut Zheng, Xing verfasserin aut Enthalten in Separation and purification technology Amsterdam [u.a.] : Elsevier Science, 1997 252 Online-Ressource (DE-627)320620123 (DE-600)2022535-0 (DE-576)259485349 nnns volume:252 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2470 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 58.11 Mechanische Verfahrenstechnik 58.13 Thermische Verfahrenstechnik AR 252 |
spelling |
10.1016/j.seppur.2020.117484 doi (DE-627)ELV004550943 (ELSEVIER)S1383-5866(20)31958-4 DE-627 ger DE-627 rda eng 540 DE-600 58.11 bkl 58.13 bkl Li, Xiaoliang verfasserin aut Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index Wu, Linjie verfasserin aut Lu, Sijia verfasserin aut Yang, Heyun verfasserin aut Xie, Wenzhou verfasserin aut Zhao, Huiyan verfasserin aut Zhang, Yaozhong verfasserin aut Cao, Xin verfasserin aut Tang, Gang verfasserin aut Li, Hesheng verfasserin aut Feng, Jiangtao verfasserin aut Yan, Wei verfasserin aut Zheng, Xing verfasserin aut Enthalten in Separation and purification technology Amsterdam [u.a.] : Elsevier Science, 1997 252 Online-Ressource (DE-627)320620123 (DE-600)2022535-0 (DE-576)259485349 nnns volume:252 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2470 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 58.11 Mechanische Verfahrenstechnik 58.13 Thermische Verfahrenstechnik AR 252 |
allfields_unstemmed |
10.1016/j.seppur.2020.117484 doi (DE-627)ELV004550943 (ELSEVIER)S1383-5866(20)31958-4 DE-627 ger DE-627 rda eng 540 DE-600 58.11 bkl 58.13 bkl Li, Xiaoliang verfasserin aut Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index Wu, Linjie verfasserin aut Lu, Sijia verfasserin aut Yang, Heyun verfasserin aut Xie, Wenzhou verfasserin aut Zhao, Huiyan verfasserin aut Zhang, Yaozhong verfasserin aut Cao, Xin verfasserin aut Tang, Gang verfasserin aut Li, Hesheng verfasserin aut Feng, Jiangtao verfasserin aut Yan, Wei verfasserin aut Zheng, Xing verfasserin aut Enthalten in Separation and purification technology Amsterdam [u.a.] : Elsevier Science, 1997 252 Online-Ressource (DE-627)320620123 (DE-600)2022535-0 (DE-576)259485349 nnns volume:252 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2470 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 58.11 Mechanische Verfahrenstechnik 58.13 Thermische Verfahrenstechnik AR 252 |
allfieldsGer |
10.1016/j.seppur.2020.117484 doi (DE-627)ELV004550943 (ELSEVIER)S1383-5866(20)31958-4 DE-627 ger DE-627 rda eng 540 DE-600 58.11 bkl 58.13 bkl Li, Xiaoliang verfasserin aut Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index Wu, Linjie verfasserin aut Lu, Sijia verfasserin aut Yang, Heyun verfasserin aut Xie, Wenzhou verfasserin aut Zhao, Huiyan verfasserin aut Zhang, Yaozhong verfasserin aut Cao, Xin verfasserin aut Tang, Gang verfasserin aut Li, Hesheng verfasserin aut Feng, Jiangtao verfasserin aut Yan, Wei verfasserin aut Zheng, Xing verfasserin aut Enthalten in Separation and purification technology Amsterdam [u.a.] : Elsevier Science, 1997 252 Online-Ressource (DE-627)320620123 (DE-600)2022535-0 (DE-576)259485349 nnns volume:252 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2470 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 58.11 Mechanische Verfahrenstechnik 58.13 Thermische Verfahrenstechnik AR 252 |
allfieldsSound |
10.1016/j.seppur.2020.117484 doi (DE-627)ELV004550943 (ELSEVIER)S1383-5866(20)31958-4 DE-627 ger DE-627 rda eng 540 DE-600 58.11 bkl 58.13 bkl Li, Xiaoliang verfasserin aut Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation 2020 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index Wu, Linjie verfasserin aut Lu, Sijia verfasserin aut Yang, Heyun verfasserin aut Xie, Wenzhou verfasserin aut Zhao, Huiyan verfasserin aut Zhang, Yaozhong verfasserin aut Cao, Xin verfasserin aut Tang, Gang verfasserin aut Li, Hesheng verfasserin aut Feng, Jiangtao verfasserin aut Yan, Wei verfasserin aut Zheng, Xing verfasserin aut Enthalten in Separation and purification technology Amsterdam [u.a.] : Elsevier Science, 1997 252 Online-Ressource (DE-627)320620123 (DE-600)2022535-0 (DE-576)259485349 nnns volume:252 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2470 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 58.11 Mechanische Verfahrenstechnik 58.13 Thermische Verfahrenstechnik AR 252 |
language |
English |
source |
Enthalten in Separation and purification technology 252 volume:252 |
sourceStr |
Enthalten in Separation and purification technology 252 volume:252 |
format_phy_str_mv |
Article |
bklname |
Mechanische Verfahrenstechnik Thermische Verfahrenstechnik |
institution |
findex.gbv.de |
topic_facet |
Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index |
dewey-raw |
540 |
isfreeaccess_bool |
false |
container_title |
Separation and purification technology |
authorswithroles_txt_mv |
Li, Xiaoliang @@aut@@ Wu, Linjie @@aut@@ Lu, Sijia @@aut@@ Yang, Heyun @@aut@@ Xie, Wenzhou @@aut@@ Zhao, Huiyan @@aut@@ Zhang, Yaozhong @@aut@@ Cao, Xin @@aut@@ Tang, Gang @@aut@@ Li, Hesheng @@aut@@ Feng, Jiangtao @@aut@@ Yan, Wei @@aut@@ Zheng, Xing @@aut@@ |
publishDateDaySort_date |
2020-01-01T00:00:00Z |
hierarchy_top_id |
320620123 |
dewey-sort |
3540 |
id |
ELV004550943 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV004550943</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230524135337.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230502s2020 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.seppur.2020.117484</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV004550943</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1383-5866(20)31958-4</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">58.11</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">58.13</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Li, Xiaoliang</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2020</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cooling tower blowdown water</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Eco-friendly process</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Biodegradability</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Toxicity</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Transcriptional effect level index</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wu, Linjie</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lu, Sijia</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yang, Heyun</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Xie, Wenzhou</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhao, Huiyan</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhang, Yaozhong</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cao, Xin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tang, Gang</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Li, Hesheng</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Feng, Jiangtao</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yan, Wei</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zheng, Xing</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Separation and purification technology</subfield><subfield code="d">Amsterdam [u.a.] : Elsevier Science, 1997</subfield><subfield code="g">252</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)320620123</subfield><subfield code="w">(DE-600)2022535-0</subfield><subfield code="w">(DE-576)259485349</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:252</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">58.11</subfield><subfield code="j">Mechanische Verfahrenstechnik</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">58.13</subfield><subfield code="j">Thermische Verfahrenstechnik</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">252</subfield></datafield></record></collection>
|
author |
Li, Xiaoliang |
spellingShingle |
Li, Xiaoliang ddc 540 bkl 58.11 bkl 58.13 misc Cooling tower blowdown water misc Eco-friendly process misc Biodegradability misc Toxicity misc Transcriptional effect level index Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation |
authorStr |
Li, Xiaoliang |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)320620123 |
format |
electronic Article |
dewey-ones |
540 - Chemistry & allied sciences |
delete_txt_mv |
keep |
author_role |
aut aut aut aut aut aut aut aut aut aut aut aut aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
540 DE-600 58.11 bkl 58.13 bkl Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation Cooling tower blowdown water Eco-friendly process Biodegradability Toxicity Transcriptional effect level index |
topic |
ddc 540 bkl 58.11 bkl 58.13 misc Cooling tower blowdown water misc Eco-friendly process misc Biodegradability misc Toxicity misc Transcriptional effect level index |
topic_unstemmed |
ddc 540 bkl 58.11 bkl 58.13 misc Cooling tower blowdown water misc Eco-friendly process misc Biodegradability misc Toxicity misc Transcriptional effect level index |
topic_browse |
ddc 540 bkl 58.11 bkl 58.13 misc Cooling tower blowdown water misc Eco-friendly process misc Biodegradability misc Toxicity misc Transcriptional effect level index |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Separation and purification technology |
hierarchy_parent_id |
320620123 |
dewey-tens |
540 - Chemistry |
hierarchy_top_title |
Separation and purification technology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)320620123 (DE-600)2022535-0 (DE-576)259485349 |
title |
Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation |
ctrlnum |
(DE-627)ELV004550943 (ELSEVIER)S1383-5866(20)31958-4 |
title_full |
Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation |
author_sort |
Li, Xiaoliang |
journal |
Separation and purification technology |
journalStr |
Separation and purification technology |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science |
recordtype |
marc |
publishDateSort |
2020 |
contenttype_str_mv |
zzz |
author_browse |
Li, Xiaoliang Wu, Linjie Lu, Sijia Yang, Heyun Xie, Wenzhou Zhao, Huiyan Zhang, Yaozhong Cao, Xin Tang, Gang Li, Hesheng Feng, Jiangtao Yan, Wei Zheng, Xing |
container_volume |
252 |
class |
540 DE-600 58.11 bkl 58.13 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Li, Xiaoliang |
doi_str_mv |
10.1016/j.seppur.2020.117484 |
dewey-full |
540 |
author2-role |
verfasserin |
title_sort |
treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: technical performance, toxicity assessment and economic evaluation |
title_auth |
Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation |
abstract |
An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. |
abstractGer |
An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. |
abstract_unstemmed |
An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment. |
collection_details |
GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_150 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2006 GBV_ILN_2008 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2088 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2470 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4046 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4322 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4325 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 |
title_short |
Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation |
remote_bool |
true |
author2 |
Wu, Linjie Lu, Sijia Yang, Heyun Xie, Wenzhou Zhao, Huiyan Zhang, Yaozhong Cao, Xin Tang, Gang Li, Hesheng Feng, Jiangtao Yan, Wei Zheng, Xing |
author2Str |
Wu, Linjie Lu, Sijia Yang, Heyun Xie, Wenzhou Zhao, Huiyan Zhang, Yaozhong Cao, Xin Tang, Gang Li, Hesheng Feng, Jiangtao Yan, Wei Zheng, Xing |
ppnlink |
320620123 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1016/j.seppur.2020.117484 |
up_date |
2024-07-06T23:22:20.577Z |
_version_ |
1803873828815765504 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV004550943</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230524135337.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230502s2020 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.seppur.2020.117484</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV004550943</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1383-5866(20)31958-4</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">58.11</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">58.13</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Li, Xiaoliang</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Treatment of cooling tower blowdown water by using adsorption-electrocatalytic oxidation: Technical performance, toxicity assessment and economic evaluation</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2020</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">An eco-friendly process was adopted to treat cooling tower blowdown water (CTBD) and the toxicity of correspondingly produced water/eluate was evaluated using the transcriptional effect level index (TELI) based on toxicogenomics. The objective of the work is to provide a feasible treatment loop including adsorption to remove organics and phosphorus from CTBD, electrocatalytic oxidation to improve the biodegradability of the eluate after desorption. Results showed that PANI/TiO2 was a promising adsorbent in the removal of organics and phosphorus from CTBD and exhibited a satisfied regeneration ability beyond 30 times of reuse. During the electrocatalytic oxidation process the biodegradability of desorption eluate was gradually increasing and BOD5/COD of the oxidized eluate reached 0.4 after 4.8 h of treatment, indicating that the treated wastewater could be returned to the biological treatment loop for further processing. The analysis of the quantitative toxicogenomics assay revealed that the toxicity of CTBD was mainly caused by oxidizing biocides of trichloroisocyanuric acid (TCCA), leading to a significant membrane stress response of bacteria. And the toxicity level of CTBD decreased after adsorption treatment while the desorption eluate experienced increase and then decrease during the electrocatalytic oxidation, meaning that certain oxidation duration was needed to keep the eluate safe for biological treatment. According to economic analysis, the operation cost of treatment loop was estimated at around 0.6 dollars/m3, ensuring high reuse water quality and safe eluate for further biological treatment.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cooling tower blowdown water</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Eco-friendly process</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Biodegradability</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Toxicity</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Transcriptional effect level index</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wu, Linjie</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lu, Sijia</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yang, Heyun</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Xie, Wenzhou</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhao, Huiyan</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhang, Yaozhong</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cao, Xin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tang, Gang</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Li, Hesheng</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Feng, Jiangtao</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Yan, Wei</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zheng, Xing</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Separation and purification technology</subfield><subfield code="d">Amsterdam [u.a.] : Elsevier Science, 1997</subfield><subfield code="g">252</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)320620123</subfield><subfield code="w">(DE-600)2022535-0</subfield><subfield code="w">(DE-576)259485349</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:252</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_150</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2006</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2008</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2088</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2470</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4322</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4325</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">58.11</subfield><subfield code="j">Mechanische Verfahrenstechnik</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">58.13</subfield><subfield code="j">Thermische Verfahrenstechnik</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">252</subfield></datafield></record></collection>
|
score |
7.3981867 |