Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton
Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic...
Ausführliche Beschreibung
Autor*in: |
Rimmele, Pia [verfasserIn] Steinhilber, Benjamin [verfasserIn] Rieger, Monika A. [verfasserIn] Luger, Tessy [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2022 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: Journal of electromyography & kinesiology - Amsterdam [u.a.] : Elsevier Science, 1991, 68 |
---|---|
Übergeordnetes Werk: |
volume:68 |
DOI / URN: |
10.1016/j.jelekin.2022.102739 |
---|
Katalog-ID: |
ELV009117784 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV009117784 | ||
003 | DE-627 | ||
005 | 20230524163122.0 | ||
007 | cr uuu---uuuuu | ||
008 | 230510s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jelekin.2022.102739 |2 doi | |
035 | |a (DE-627)ELV009117784 | ||
035 | |a (ELSEVIER)S1050-6411(22)00112-2 | ||
040 | |a DE-627 |b ger |c DE-627 |e rda | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q DE-600 |
084 | |a 44.83 |2 bkl | ||
100 | 1 | |a Rimmele, Pia |e verfasserin |4 aut | |
245 | 1 | 0 | |a Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
264 | 1 | |c 2022 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
520 | |a Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. | ||
650 | 4 | |a Movement variability | |
650 | 4 | |a Squat lifting | |
650 | 4 | |a Stoop lifting | |
650 | 4 | |a Assistive device | |
650 | 4 | |a Electromyography | |
650 | 4 | |a Kinematics | |
650 | 4 | |a Spine | |
700 | 1 | |a Steinhilber, Benjamin |e verfasserin |4 aut | |
700 | 1 | |a Rieger, Monika A. |e verfasserin |4 aut | |
700 | 1 | |a Luger, Tessy |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Journal of electromyography & kinesiology |d Amsterdam [u.a.] : Elsevier Science, 1991 |g 68 |h Online-Ressource |w (DE-627)320456803 |w (DE-600)2006766-5 |w (DE-576)264627407 |x 1873-5711 |7 nnns |
773 | 1 | 8 | |g volume:68 |
912 | |a GBV_USEFLAG_U | ||
912 | |a SYSFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SSG-OLC-PHA | ||
912 | |a GBV_ILN_20 | ||
912 | |a GBV_ILN_22 | ||
912 | |a GBV_ILN_23 | ||
912 | |a GBV_ILN_24 | ||
912 | |a GBV_ILN_31 | ||
912 | |a GBV_ILN_32 | ||
912 | |a GBV_ILN_40 | ||
912 | |a GBV_ILN_60 | ||
912 | |a GBV_ILN_62 | ||
912 | |a GBV_ILN_63 | ||
912 | |a GBV_ILN_65 | ||
912 | |a GBV_ILN_69 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_73 | ||
912 | |a GBV_ILN_74 | ||
912 | |a GBV_ILN_90 | ||
912 | |a GBV_ILN_95 | ||
912 | |a GBV_ILN_100 | ||
912 | |a GBV_ILN_101 | ||
912 | |a GBV_ILN_105 | ||
912 | |a GBV_ILN_110 | ||
912 | |a GBV_ILN_151 | ||
912 | |a GBV_ILN_224 | ||
912 | |a GBV_ILN_370 | ||
912 | |a GBV_ILN_602 | ||
912 | |a GBV_ILN_702 | ||
912 | |a GBV_ILN_2003 | ||
912 | |a GBV_ILN_2004 | ||
912 | |a GBV_ILN_2005 | ||
912 | |a GBV_ILN_2011 | ||
912 | |a GBV_ILN_2014 | ||
912 | |a GBV_ILN_2015 | ||
912 | |a GBV_ILN_2020 | ||
912 | |a GBV_ILN_2021 | ||
912 | |a GBV_ILN_2025 | ||
912 | |a GBV_ILN_2027 | ||
912 | |a GBV_ILN_2034 | ||
912 | |a GBV_ILN_2038 | ||
912 | |a GBV_ILN_2044 | ||
912 | |a GBV_ILN_2048 | ||
912 | |a GBV_ILN_2049 | ||
912 | |a GBV_ILN_2050 | ||
912 | |a GBV_ILN_2056 | ||
912 | |a GBV_ILN_2059 | ||
912 | |a GBV_ILN_2061 | ||
912 | |a GBV_ILN_2064 | ||
912 | |a GBV_ILN_2065 | ||
912 | |a GBV_ILN_2068 | ||
912 | |a GBV_ILN_2111 | ||
912 | |a GBV_ILN_2112 | ||
912 | |a GBV_ILN_2113 | ||
912 | |a GBV_ILN_2118 | ||
912 | |a GBV_ILN_2122 | ||
912 | |a GBV_ILN_2129 | ||
912 | |a GBV_ILN_2143 | ||
912 | |a GBV_ILN_2147 | ||
912 | |a GBV_ILN_2148 | ||
912 | |a GBV_ILN_2152 | ||
912 | |a GBV_ILN_2153 | ||
912 | |a GBV_ILN_2190 | ||
912 | |a GBV_ILN_2336 | ||
912 | |a GBV_ILN_2507 | ||
912 | |a GBV_ILN_2522 | ||
912 | |a GBV_ILN_4035 | ||
912 | |a GBV_ILN_4037 | ||
912 | |a GBV_ILN_4112 | ||
912 | |a GBV_ILN_4125 | ||
912 | |a GBV_ILN_4126 | ||
912 | |a GBV_ILN_4242 | ||
912 | |a GBV_ILN_4251 | ||
912 | |a GBV_ILN_4305 | ||
912 | |a GBV_ILN_4313 | ||
912 | |a GBV_ILN_4323 | ||
912 | |a GBV_ILN_4324 | ||
912 | |a GBV_ILN_4326 | ||
912 | |a GBV_ILN_4333 | ||
912 | |a GBV_ILN_4334 | ||
912 | |a GBV_ILN_4335 | ||
912 | |a GBV_ILN_4338 | ||
912 | |a GBV_ILN_4393 | ||
936 | b | k | |a 44.83 |j Rheumatologie |j Orthopädie |
951 | |a AR | ||
952 | |d 68 |
author_variant |
p r pr b s bs m a r ma mar t l tl |
---|---|
matchkey_str |
article:18735711:2022----::oovraiiyuigrpttvlfigaksmardyernaas |
hierarchy_sort_str |
2022 |
bklnumber |
44.83 |
publishDate |
2022 |
allfields |
10.1016/j.jelekin.2022.102739 doi (DE-627)ELV009117784 (ELSEVIER)S1050-6411(22)00112-2 DE-627 ger DE-627 rda eng 610 DE-600 44.83 bkl Rimmele, Pia verfasserin aut Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton 2022 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine Steinhilber, Benjamin verfasserin aut Rieger, Monika A. verfasserin aut Luger, Tessy verfasserin aut Enthalten in Journal of electromyography & kinesiology Amsterdam [u.a.] : Elsevier Science, 1991 68 Online-Ressource (DE-627)320456803 (DE-600)2006766-5 (DE-576)264627407 1873-5711 nnns volume:68 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.83 Rheumatologie Orthopädie AR 68 |
spelling |
10.1016/j.jelekin.2022.102739 doi (DE-627)ELV009117784 (ELSEVIER)S1050-6411(22)00112-2 DE-627 ger DE-627 rda eng 610 DE-600 44.83 bkl Rimmele, Pia verfasserin aut Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton 2022 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine Steinhilber, Benjamin verfasserin aut Rieger, Monika A. verfasserin aut Luger, Tessy verfasserin aut Enthalten in Journal of electromyography & kinesiology Amsterdam [u.a.] : Elsevier Science, 1991 68 Online-Ressource (DE-627)320456803 (DE-600)2006766-5 (DE-576)264627407 1873-5711 nnns volume:68 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.83 Rheumatologie Orthopädie AR 68 |
allfields_unstemmed |
10.1016/j.jelekin.2022.102739 doi (DE-627)ELV009117784 (ELSEVIER)S1050-6411(22)00112-2 DE-627 ger DE-627 rda eng 610 DE-600 44.83 bkl Rimmele, Pia verfasserin aut Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton 2022 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine Steinhilber, Benjamin verfasserin aut Rieger, Monika A. verfasserin aut Luger, Tessy verfasserin aut Enthalten in Journal of electromyography & kinesiology Amsterdam [u.a.] : Elsevier Science, 1991 68 Online-Ressource (DE-627)320456803 (DE-600)2006766-5 (DE-576)264627407 1873-5711 nnns volume:68 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.83 Rheumatologie Orthopädie AR 68 |
allfieldsGer |
10.1016/j.jelekin.2022.102739 doi (DE-627)ELV009117784 (ELSEVIER)S1050-6411(22)00112-2 DE-627 ger DE-627 rda eng 610 DE-600 44.83 bkl Rimmele, Pia verfasserin aut Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton 2022 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine Steinhilber, Benjamin verfasserin aut Rieger, Monika A. verfasserin aut Luger, Tessy verfasserin aut Enthalten in Journal of electromyography & kinesiology Amsterdam [u.a.] : Elsevier Science, 1991 68 Online-Ressource (DE-627)320456803 (DE-600)2006766-5 (DE-576)264627407 1873-5711 nnns volume:68 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.83 Rheumatologie Orthopädie AR 68 |
allfieldsSound |
10.1016/j.jelekin.2022.102739 doi (DE-627)ELV009117784 (ELSEVIER)S1050-6411(22)00112-2 DE-627 ger DE-627 rda eng 610 DE-600 44.83 bkl Rimmele, Pia verfasserin aut Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton 2022 nicht spezifiziert zzz rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine Steinhilber, Benjamin verfasserin aut Rieger, Monika A. verfasserin aut Luger, Tessy verfasserin aut Enthalten in Journal of electromyography & kinesiology Amsterdam [u.a.] : Elsevier Science, 1991 68 Online-Ressource (DE-627)320456803 (DE-600)2006766-5 (DE-576)264627407 1873-5711 nnns volume:68 GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 44.83 Rheumatologie Orthopädie AR 68 |
language |
English |
source |
Enthalten in Journal of electromyography & kinesiology 68 volume:68 |
sourceStr |
Enthalten in Journal of electromyography & kinesiology 68 volume:68 |
format_phy_str_mv |
Article |
bklname |
Rheumatologie Orthopädie |
institution |
findex.gbv.de |
topic_facet |
Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
Journal of electromyography & kinesiology |
authorswithroles_txt_mv |
Rimmele, Pia @@aut@@ Steinhilber, Benjamin @@aut@@ Rieger, Monika A. @@aut@@ Luger, Tessy @@aut@@ |
publishDateDaySort_date |
2022-01-01T00:00:00Z |
hierarchy_top_id |
320456803 |
dewey-sort |
3610 |
id |
ELV009117784 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV009117784</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230524163122.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230510s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jelekin.2022.102739</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV009117784</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1050-6411(22)00112-2</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.83</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Rimmele, Pia</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Movement variability</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Squat lifting</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Stoop lifting</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Assistive device</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Electromyography</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Kinematics</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Spine</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Steinhilber, Benjamin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rieger, Monika A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Luger, Tessy</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Journal of electromyography & kinesiology</subfield><subfield code="d">Amsterdam [u.a.] : Elsevier Science, 1991</subfield><subfield code="g">68</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)320456803</subfield><subfield code="w">(DE-600)2006766-5</subfield><subfield code="w">(DE-576)264627407</subfield><subfield code="x">1873-5711</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:68</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.83</subfield><subfield code="j">Rheumatologie</subfield><subfield code="j">Orthopädie</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">68</subfield></datafield></record></collection>
|
author |
Rimmele, Pia |
spellingShingle |
Rimmele, Pia ddc 610 bkl 44.83 misc Movement variability misc Squat lifting misc Stoop lifting misc Assistive device misc Electromyography misc Kinematics misc Spine Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
authorStr |
Rimmele, Pia |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)320456803 |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut aut aut aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1873-5711 |
topic_title |
610 DE-600 44.83 bkl Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton Movement variability Squat lifting Stoop lifting Assistive device Electromyography Kinematics Spine |
topic |
ddc 610 bkl 44.83 misc Movement variability misc Squat lifting misc Stoop lifting misc Assistive device misc Electromyography misc Kinematics misc Spine |
topic_unstemmed |
ddc 610 bkl 44.83 misc Movement variability misc Squat lifting misc Stoop lifting misc Assistive device misc Electromyography misc Kinematics misc Spine |
topic_browse |
ddc 610 bkl 44.83 misc Movement variability misc Squat lifting misc Stoop lifting misc Assistive device misc Electromyography misc Kinematics misc Spine |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Journal of electromyography & kinesiology |
hierarchy_parent_id |
320456803 |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
Journal of electromyography & kinesiology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)320456803 (DE-600)2006766-5 (DE-576)264627407 |
title |
Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
ctrlnum |
(DE-627)ELV009117784 (ELSEVIER)S1050-6411(22)00112-2 |
title_full |
Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
author_sort |
Rimmele, Pia |
journal |
Journal of electromyography & kinesiology |
journalStr |
Journal of electromyography & kinesiology |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2022 |
contenttype_str_mv |
zzz |
author_browse |
Rimmele, Pia Steinhilber, Benjamin Rieger, Monika A. Luger, Tessy |
container_volume |
68 |
class |
610 DE-600 44.83 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Rimmele, Pia |
doi_str_mv |
10.1016/j.jelekin.2022.102739 |
dewey-full |
610 |
author2-role |
verfasserin |
title_sort |
motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
title_auth |
Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
abstract |
Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. |
abstractGer |
Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. |
abstract_unstemmed |
Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated. |
collection_details |
GBV_USEFLAG_U SYSFLAG_U GBV_ELV SSG-OLC-PHA GBV_ILN_20 GBV_ILN_22 GBV_ILN_23 GBV_ILN_24 GBV_ILN_31 GBV_ILN_32 GBV_ILN_40 GBV_ILN_60 GBV_ILN_62 GBV_ILN_63 GBV_ILN_65 GBV_ILN_69 GBV_ILN_70 GBV_ILN_73 GBV_ILN_74 GBV_ILN_90 GBV_ILN_95 GBV_ILN_100 GBV_ILN_101 GBV_ILN_105 GBV_ILN_110 GBV_ILN_151 GBV_ILN_224 GBV_ILN_370 GBV_ILN_602 GBV_ILN_702 GBV_ILN_2003 GBV_ILN_2004 GBV_ILN_2005 GBV_ILN_2011 GBV_ILN_2014 GBV_ILN_2015 GBV_ILN_2020 GBV_ILN_2021 GBV_ILN_2025 GBV_ILN_2027 GBV_ILN_2034 GBV_ILN_2038 GBV_ILN_2044 GBV_ILN_2048 GBV_ILN_2049 GBV_ILN_2050 GBV_ILN_2056 GBV_ILN_2059 GBV_ILN_2061 GBV_ILN_2064 GBV_ILN_2065 GBV_ILN_2068 GBV_ILN_2111 GBV_ILN_2112 GBV_ILN_2113 GBV_ILN_2118 GBV_ILN_2122 GBV_ILN_2129 GBV_ILN_2143 GBV_ILN_2147 GBV_ILN_2148 GBV_ILN_2152 GBV_ILN_2153 GBV_ILN_2190 GBV_ILN_2336 GBV_ILN_2507 GBV_ILN_2522 GBV_ILN_4035 GBV_ILN_4037 GBV_ILN_4112 GBV_ILN_4125 GBV_ILN_4126 GBV_ILN_4242 GBV_ILN_4251 GBV_ILN_4305 GBV_ILN_4313 GBV_ILN_4323 GBV_ILN_4324 GBV_ILN_4326 GBV_ILN_4333 GBV_ILN_4334 GBV_ILN_4335 GBV_ILN_4338 GBV_ILN_4393 |
title_short |
Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton |
remote_bool |
true |
author2 |
Steinhilber, Benjamin Rieger, Monika A. Luger, Tessy |
author2Str |
Steinhilber, Benjamin Rieger, Monika A. Luger, Tessy |
ppnlink |
320456803 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1016/j.jelekin.2022.102739 |
up_date |
2024-07-06T22:03:22.493Z |
_version_ |
1803868860573548544 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV009117784</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230524163122.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">230510s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jelekin.2022.102739</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV009117784</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1050-6411(22)00112-2</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rda</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.83</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Rimmele, Pia</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Motor variability during a repetitive lifting task is impaired by wearing a passive back-support exoskeleton</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Purpose: Evaluate whether wearing a passive back-support exoskeleton during repetitive lifting impairs motor variability of erector spinae muscle and spine movement and whether this association is influenced by lifting style.Results: For the complete lifting cycle, muscular variability and thoracic kyphosis variability decreased whereas lumbar lordosis variability increased with exoskeleton. For lifting phases, effects of exoskeleton were mixed. Absolute and relative muscular variability showed a significant interaction effect for the phase straighten with load; variability decreased with exoskeleton during squat lifting.Conclusion: Using the exoskeleton impaired several motor variability parameters during lifting, supporting previous findings that exoskeletons may limit freedom of movement. The impact of this result on longer-term development of muscular fatigue or musculoskeletal disorders cannot yet be estimated.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Movement variability</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Squat lifting</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Stoop lifting</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Assistive device</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Electromyography</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Kinematics</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Spine</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Steinhilber, Benjamin</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rieger, Monika A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Luger, Tessy</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Journal of electromyography & kinesiology</subfield><subfield code="d">Amsterdam [u.a.] : Elsevier Science, 1991</subfield><subfield code="g">68</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)320456803</subfield><subfield code="w">(DE-600)2006766-5</subfield><subfield code="w">(DE-576)264627407</subfield><subfield code="x">1873-5711</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:68</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_20</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_22</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_23</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_24</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_31</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_32</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_40</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_60</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_62</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_63</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_65</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_69</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_73</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_74</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_90</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_95</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_100</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_101</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_105</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_110</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_151</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_224</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_370</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_602</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_702</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2003</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2004</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2005</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2011</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2014</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2015</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2020</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2021</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2025</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2027</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2034</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2038</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2044</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2049</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2050</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2056</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2059</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2061</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2064</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2065</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2068</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2111</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2113</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2118</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2122</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2129</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2143</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2147</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2148</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2152</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2153</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2190</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2336</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2507</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2522</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4035</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4037</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4112</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4125</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4126</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4242</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4251</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4305</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4313</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4323</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4324</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4326</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4333</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4334</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4335</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4338</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4393</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.83</subfield><subfield code="j">Rheumatologie</subfield><subfield code="j">Orthopädie</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">68</subfield></datafield></record></collection>
|
score |
7.399109 |