Understanding the effectiveness of cathodic protection under disbonded coatings
• A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitat...
Ausführliche Beschreibung
Autor*in: |
Varela, F. [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2015 |
---|
Schlagwörter: |
---|
Umfang: |
14 |
---|
Übergeordnetes Werk: |
Enthalten in: Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch - Zhang, Lei ELSEVIER, 2018, the journal of the International Society of Electrochemistry (ISE), New York, NY [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:186 ; year:2015 ; day:20 ; month:12 ; pages:377-390 ; extent:14 |
Links: |
---|
DOI / URN: |
10.1016/j.electacta.2015.10.171 |
---|
Katalog-ID: |
ELV013402498 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV013402498 | ||
003 | DE-627 | ||
005 | 20230623105001.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180602s2015 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.electacta.2015.10.171 |2 doi | |
028 | 5 | 2 | |a GBVA2015021000004.pica |
035 | |a (DE-627)ELV013402498 | ||
035 | |a (ELSEVIER)S0013-4686(15)30752-0 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | |a 540 | |
082 | 0 | 4 | |a 540 |q DE-600 |
082 | 0 | 4 | |a 610 |q VZ |
084 | |a 44.00 |2 bkl | ||
100 | 1 | |a Varela, F. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Understanding the effectiveness of cathodic protection under disbonded coatings |
264 | 1 | |c 2015 | |
300 | |a 14 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a • A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. | ||
650 | 7 | |a Disbonded coating |2 Elsevier | |
650 | 7 | |a Cathodic shielding |2 Elsevier | |
650 | 7 | |a Current distribution |2 Elsevier | |
650 | 7 | |a Electrode array |2 Elsevier | |
700 | 1 | |a Tan, M.Y.J. |4 oth | |
700 | 1 | |a Forsyth, M. |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier |a Zhang, Lei ELSEVIER |t Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch |d 2018 |d the journal of the International Society of Electrochemistry (ISE) |g New York, NY [u.a.] |w (DE-627)ELV001212419 |
773 | 1 | 8 | |g volume:186 |g year:2015 |g day:20 |g month:12 |g pages:377-390 |g extent:14 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.electacta.2015.10.171 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 44.00 |j Medizin: Allgemeines |q VZ |
951 | |a AR | ||
952 | |d 186 |j 2015 |b 20 |c 1220 |h 377-390 |g 14 | ||
953 | |2 045F |a 540 |
author_variant |
f v fv |
---|---|
matchkey_str |
varelaftanmyjforsythm:2015----:nesadntefetvnsoctoipoetou |
hierarchy_sort_str |
2015 |
bklnumber |
44.00 |
publishDate |
2015 |
allfields |
10.1016/j.electacta.2015.10.171 doi GBVA2015021000004.pica (DE-627)ELV013402498 (ELSEVIER)S0013-4686(15)30752-0 DE-627 ger DE-627 rakwb eng 540 540 DE-600 610 VZ 44.00 bkl Varela, F. verfasserin aut Understanding the effectiveness of cathodic protection under disbonded coatings 2015 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Elsevier Tan, M.Y.J. oth Forsyth, M. oth Enthalten in Elsevier Zhang, Lei ELSEVIER Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch 2018 the journal of the International Society of Electrochemistry (ISE) New York, NY [u.a.] (DE-627)ELV001212419 volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 https://doi.org/10.1016/j.electacta.2015.10.171 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.00 Medizin: Allgemeines VZ AR 186 2015 20 1220 377-390 14 045F 540 |
spelling |
10.1016/j.electacta.2015.10.171 doi GBVA2015021000004.pica (DE-627)ELV013402498 (ELSEVIER)S0013-4686(15)30752-0 DE-627 ger DE-627 rakwb eng 540 540 DE-600 610 VZ 44.00 bkl Varela, F. verfasserin aut Understanding the effectiveness of cathodic protection under disbonded coatings 2015 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Elsevier Tan, M.Y.J. oth Forsyth, M. oth Enthalten in Elsevier Zhang, Lei ELSEVIER Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch 2018 the journal of the International Society of Electrochemistry (ISE) New York, NY [u.a.] (DE-627)ELV001212419 volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 https://doi.org/10.1016/j.electacta.2015.10.171 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.00 Medizin: Allgemeines VZ AR 186 2015 20 1220 377-390 14 045F 540 |
allfields_unstemmed |
10.1016/j.electacta.2015.10.171 doi GBVA2015021000004.pica (DE-627)ELV013402498 (ELSEVIER)S0013-4686(15)30752-0 DE-627 ger DE-627 rakwb eng 540 540 DE-600 610 VZ 44.00 bkl Varela, F. verfasserin aut Understanding the effectiveness of cathodic protection under disbonded coatings 2015 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Elsevier Tan, M.Y.J. oth Forsyth, M. oth Enthalten in Elsevier Zhang, Lei ELSEVIER Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch 2018 the journal of the International Society of Electrochemistry (ISE) New York, NY [u.a.] (DE-627)ELV001212419 volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 https://doi.org/10.1016/j.electacta.2015.10.171 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.00 Medizin: Allgemeines VZ AR 186 2015 20 1220 377-390 14 045F 540 |
allfieldsGer |
10.1016/j.electacta.2015.10.171 doi GBVA2015021000004.pica (DE-627)ELV013402498 (ELSEVIER)S0013-4686(15)30752-0 DE-627 ger DE-627 rakwb eng 540 540 DE-600 610 VZ 44.00 bkl Varela, F. verfasserin aut Understanding the effectiveness of cathodic protection under disbonded coatings 2015 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Elsevier Tan, M.Y.J. oth Forsyth, M. oth Enthalten in Elsevier Zhang, Lei ELSEVIER Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch 2018 the journal of the International Society of Electrochemistry (ISE) New York, NY [u.a.] (DE-627)ELV001212419 volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 https://doi.org/10.1016/j.electacta.2015.10.171 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.00 Medizin: Allgemeines VZ AR 186 2015 20 1220 377-390 14 045F 540 |
allfieldsSound |
10.1016/j.electacta.2015.10.171 doi GBVA2015021000004.pica (DE-627)ELV013402498 (ELSEVIER)S0013-4686(15)30752-0 DE-627 ger DE-627 rakwb eng 540 540 DE-600 610 VZ 44.00 bkl Varela, F. verfasserin aut Understanding the effectiveness of cathodic protection under disbonded coatings 2015 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Elsevier Tan, M.Y.J. oth Forsyth, M. oth Enthalten in Elsevier Zhang, Lei ELSEVIER Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch 2018 the journal of the International Society of Electrochemistry (ISE) New York, NY [u.a.] (DE-627)ELV001212419 volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 https://doi.org/10.1016/j.electacta.2015.10.171 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.00 Medizin: Allgemeines VZ AR 186 2015 20 1220 377-390 14 045F 540 |
language |
English |
source |
Enthalten in Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch New York, NY [u.a.] volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 |
sourceStr |
Enthalten in Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch New York, NY [u.a.] volume:186 year:2015 day:20 month:12 pages:377-390 extent:14 |
format_phy_str_mv |
Article |
bklname |
Medizin: Allgemeines |
institution |
findex.gbv.de |
topic_facet |
Disbonded coating Cathodic shielding Current distribution Electrode array |
dewey-raw |
540 |
isfreeaccess_bool |
false |
container_title |
Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch |
authorswithroles_txt_mv |
Varela, F. @@aut@@ Tan, M.Y.J. @@oth@@ Forsyth, M. @@oth@@ |
publishDateDaySort_date |
2015-01-20T00:00:00Z |
hierarchy_top_id |
ELV001212419 |
dewey-sort |
3540 |
id |
ELV013402498 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV013402498</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623105001.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180602s2015 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.electacta.2015.10.171</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2015021000004.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV013402498</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0013-4686(15)30752-0</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">540</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Varela, F.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Understanding the effectiveness of cathodic protection under disbonded coatings</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2015</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">14</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Disbonded coating</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Cathodic shielding</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Current distribution</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Electrode array</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tan, M.Y.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Forsyth, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier</subfield><subfield code="a">Zhang, Lei ELSEVIER</subfield><subfield code="t">Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch</subfield><subfield code="d">2018</subfield><subfield code="d">the journal of the International Society of Electrochemistry (ISE)</subfield><subfield code="g">New York, NY [u.a.]</subfield><subfield code="w">(DE-627)ELV001212419</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:186</subfield><subfield code="g">year:2015</subfield><subfield code="g">day:20</subfield><subfield code="g">month:12</subfield><subfield code="g">pages:377-390</subfield><subfield code="g">extent:14</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.electacta.2015.10.171</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.00</subfield><subfield code="j">Medizin: Allgemeines</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">186</subfield><subfield code="j">2015</subfield><subfield code="b">20</subfield><subfield code="c">1220</subfield><subfield code="h">377-390</subfield><subfield code="g">14</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">540</subfield></datafield></record></collection>
|
author |
Varela, F. |
spellingShingle |
Varela, F. ddc 540 ddc 610 bkl 44.00 Elsevier Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Understanding the effectiveness of cathodic protection under disbonded coatings |
authorStr |
Varela, F. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV001212419 |
format |
electronic Article |
dewey-ones |
540 - Chemistry & allied sciences 610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
540 540 DE-600 610 VZ 44.00 bkl Understanding the effectiveness of cathodic protection under disbonded coatings Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array Elsevier |
topic |
ddc 540 ddc 610 bkl 44.00 Elsevier Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array |
topic_unstemmed |
ddc 540 ddc 610 bkl 44.00 Elsevier Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array |
topic_browse |
ddc 540 ddc 610 bkl 44.00 Elsevier Disbonded coating Elsevier Cathodic shielding Elsevier Current distribution Elsevier Electrode array |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
m t mt m f mf |
hierarchy_parent_title |
Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch |
hierarchy_parent_id |
ELV001212419 |
dewey-tens |
540 - Chemistry 610 - Medicine & health |
hierarchy_top_title |
Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV001212419 |
title |
Understanding the effectiveness of cathodic protection under disbonded coatings |
ctrlnum |
(DE-627)ELV013402498 (ELSEVIER)S0013-4686(15)30752-0 |
title_full |
Understanding the effectiveness of cathodic protection under disbonded coatings |
author_sort |
Varela, F. |
journal |
Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch |
journalStr |
Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science 600 - Technology |
recordtype |
marc |
publishDateSort |
2015 |
contenttype_str_mv |
zzz |
container_start_page |
377 |
author_browse |
Varela, F. |
container_volume |
186 |
physical |
14 |
class |
540 540 DE-600 610 VZ 44.00 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Varela, F. |
doi_str_mv |
10.1016/j.electacta.2015.10.171 |
dewey-full |
540 610 |
title_sort |
understanding the effectiveness of cathodic protection under disbonded coatings |
title_auth |
Understanding the effectiveness of cathodic protection under disbonded coatings |
abstract |
• A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. |
abstractGer |
• A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. |
abstract_unstemmed |
• A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA |
title_short |
Understanding the effectiveness of cathodic protection under disbonded coatings |
url |
https://doi.org/10.1016/j.electacta.2015.10.171 |
remote_bool |
true |
author2 |
Tan, M.Y.J. Forsyth, M. |
author2Str |
Tan, M.Y.J. Forsyth, M. |
ppnlink |
ELV001212419 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
doi_str |
10.1016/j.electacta.2015.10.171 |
up_date |
2024-07-06T18:49:03.861Z |
_version_ |
1803856635611840512 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV013402498</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623105001.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180602s2015 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.electacta.2015.10.171</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2015021000004.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV013402498</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0013-4686(15)30752-0</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">540</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Varela, F.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Understanding the effectiveness of cathodic protection under disbonded coatings</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2015</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">14</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• A systematic study of CP current distribution under disbonded coatings is presented. • The effects of CP potential, solution conductivity and crevice gap size have been analysed. • It has been found that local pH determines the rate of corrosion at CP shielded locations. • The accuracy and limitations of prior mathematical models have been experimentally assessed. • A new model is presented to explain the CP current distribution under disbonded coatings.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Disbonded coating</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Cathodic shielding</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Current distribution</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Electrode array</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tan, M.Y.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Forsyth, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier</subfield><subfield code="a">Zhang, Lei ELSEVIER</subfield><subfield code="t">Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch</subfield><subfield code="d">2018</subfield><subfield code="d">the journal of the International Society of Electrochemistry (ISE)</subfield><subfield code="g">New York, NY [u.a.]</subfield><subfield code="w">(DE-627)ELV001212419</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:186</subfield><subfield code="g">year:2015</subfield><subfield code="g">day:20</subfield><subfield code="g">month:12</subfield><subfield code="g">pages:377-390</subfield><subfield code="g">extent:14</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.electacta.2015.10.171</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.00</subfield><subfield code="j">Medizin: Allgemeines</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">186</subfield><subfield code="j">2015</subfield><subfield code="b">20</subfield><subfield code="c">1220</subfield><subfield code="h">377-390</subfield><subfield code="g">14</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">540</subfield></datafield></record></collection>
|
score |
7.399953 |