mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams
• Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy.
Autor*in: |
Bell, Katharina [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2016 |
---|
Schlagwörter: |
Varian Eclipse treatment planning system |
---|
Umfang: |
5 |
---|
Übergeordnetes Werk: |
Enthalten in: An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study - Almanassra, Ismail W. ELSEVIER, 2019, European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology, Amsterdam |
---|---|
Übergeordnetes Werk: |
volume:32 ; year:2016 ; number:3 ; pages:474-478 ; extent:5 |
Links: |
---|
DOI / URN: |
10.1016/j.ejmp.2016.02.011 |
---|
Katalog-ID: |
ELV014439751 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV014439751 | ||
003 | DE-627 | ||
005 | 20230623113955.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180602s2016 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.ejmp.2016.02.011 |2 doi | |
028 | 5 | 2 | |a GBVA2016018000005.pica |
035 | |a (DE-627)ELV014439751 | ||
035 | |a (ELSEVIER)S1120-1797(16)00521-4 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | |a 530 |a 610 | |
082 | 0 | 4 | |a 530 |q DNB |
082 | 0 | 4 | |a 610 |q DNB |
082 | 0 | 4 | |a 540 |q VZ |
084 | |a 35.21 |2 bkl | ||
100 | 1 | |a Bell, Katharina |e verfasserin |4 aut | |
245 | 1 | 0 | |a mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams |
264 | 1 | |c 2016 | |
300 | |a 5 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a • Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. | ||
650 | 7 | |a Varian Eclipse treatment planning system |2 Elsevier | |
650 | 7 | |a Flattening-filter-free beam energy |2 Elsevier | |
650 | 7 | |a Prostate cancer |2 Elsevier | |
650 | 7 | |a mARC rotational treatment |2 Elsevier | |
700 | 1 | |a Dzierma, Yvonne |4 oth | |
700 | 1 | |a Palm, Jan |4 oth | |
700 | 1 | |a Nuesken, Frank |4 oth | |
700 | 1 | |a Licht, Norbert |4 oth | |
700 | 1 | |a Rübe, Christian |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier |a Almanassra, Ismail W. ELSEVIER |t An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study |d 2019 |d European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology |g Amsterdam |w (DE-627)ELV003857336 |
773 | 1 | 8 | |g volume:32 |g year:2016 |g number:3 |g pages:474-478 |g extent:5 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.ejmp.2016.02.011 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 35.21 |j Lösungen |j Flüssigkeiten |x Physikalische Chemie |q VZ |
951 | |a AR | ||
952 | |d 32 |j 2016 |e 3 |h 474-478 |g 5 | ||
953 | |2 045F |a 530 |
author_variant |
k b kb |
---|---|
matchkey_str |
bellkatharinadziermayvonnepalmjannuesken:2016----:acrsaeramnpannwtvraelp |
hierarchy_sort_str |
2016 |
bklnumber |
35.21 |
publishDate |
2016 |
allfields |
10.1016/j.ejmp.2016.02.011 doi GBVA2016018000005.pica (DE-627)ELV014439751 (ELSEVIER)S1120-1797(16)00521-4 DE-627 ger DE-627 rakwb eng 530 610 530 DNB 610 DNB 540 VZ 35.21 bkl Bell, Katharina verfasserin aut mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams 2016 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment Elsevier Dzierma, Yvonne oth Palm, Jan oth Nuesken, Frank oth Licht, Norbert oth Rübe, Christian oth Enthalten in Elsevier Almanassra, Ismail W. ELSEVIER An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study 2019 European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology Amsterdam (DE-627)ELV003857336 volume:32 year:2016 number:3 pages:474-478 extent:5 https://doi.org/10.1016/j.ejmp.2016.02.011 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.21 Lösungen Flüssigkeiten Physikalische Chemie VZ AR 32 2016 3 474-478 5 045F 530 |
spelling |
10.1016/j.ejmp.2016.02.011 doi GBVA2016018000005.pica (DE-627)ELV014439751 (ELSEVIER)S1120-1797(16)00521-4 DE-627 ger DE-627 rakwb eng 530 610 530 DNB 610 DNB 540 VZ 35.21 bkl Bell, Katharina verfasserin aut mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams 2016 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment Elsevier Dzierma, Yvonne oth Palm, Jan oth Nuesken, Frank oth Licht, Norbert oth Rübe, Christian oth Enthalten in Elsevier Almanassra, Ismail W. ELSEVIER An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study 2019 European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology Amsterdam (DE-627)ELV003857336 volume:32 year:2016 number:3 pages:474-478 extent:5 https://doi.org/10.1016/j.ejmp.2016.02.011 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.21 Lösungen Flüssigkeiten Physikalische Chemie VZ AR 32 2016 3 474-478 5 045F 530 |
allfields_unstemmed |
10.1016/j.ejmp.2016.02.011 doi GBVA2016018000005.pica (DE-627)ELV014439751 (ELSEVIER)S1120-1797(16)00521-4 DE-627 ger DE-627 rakwb eng 530 610 530 DNB 610 DNB 540 VZ 35.21 bkl Bell, Katharina verfasserin aut mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams 2016 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment Elsevier Dzierma, Yvonne oth Palm, Jan oth Nuesken, Frank oth Licht, Norbert oth Rübe, Christian oth Enthalten in Elsevier Almanassra, Ismail W. ELSEVIER An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study 2019 European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology Amsterdam (DE-627)ELV003857336 volume:32 year:2016 number:3 pages:474-478 extent:5 https://doi.org/10.1016/j.ejmp.2016.02.011 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.21 Lösungen Flüssigkeiten Physikalische Chemie VZ AR 32 2016 3 474-478 5 045F 530 |
allfieldsGer |
10.1016/j.ejmp.2016.02.011 doi GBVA2016018000005.pica (DE-627)ELV014439751 (ELSEVIER)S1120-1797(16)00521-4 DE-627 ger DE-627 rakwb eng 530 610 530 DNB 610 DNB 540 VZ 35.21 bkl Bell, Katharina verfasserin aut mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams 2016 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment Elsevier Dzierma, Yvonne oth Palm, Jan oth Nuesken, Frank oth Licht, Norbert oth Rübe, Christian oth Enthalten in Elsevier Almanassra, Ismail W. ELSEVIER An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study 2019 European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology Amsterdam (DE-627)ELV003857336 volume:32 year:2016 number:3 pages:474-478 extent:5 https://doi.org/10.1016/j.ejmp.2016.02.011 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.21 Lösungen Flüssigkeiten Physikalische Chemie VZ AR 32 2016 3 474-478 5 045F 530 |
allfieldsSound |
10.1016/j.ejmp.2016.02.011 doi GBVA2016018000005.pica (DE-627)ELV014439751 (ELSEVIER)S1120-1797(16)00521-4 DE-627 ger DE-627 rakwb eng 530 610 530 DNB 610 DNB 540 VZ 35.21 bkl Bell, Katharina verfasserin aut mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams 2016 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment Elsevier Dzierma, Yvonne oth Palm, Jan oth Nuesken, Frank oth Licht, Norbert oth Rübe, Christian oth Enthalten in Elsevier Almanassra, Ismail W. ELSEVIER An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study 2019 European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology Amsterdam (DE-627)ELV003857336 volume:32 year:2016 number:3 pages:474-478 extent:5 https://doi.org/10.1016/j.ejmp.2016.02.011 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.21 Lösungen Flüssigkeiten Physikalische Chemie VZ AR 32 2016 3 474-478 5 045F 530 |
language |
English |
source |
Enthalten in An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study Amsterdam volume:32 year:2016 number:3 pages:474-478 extent:5 |
sourceStr |
Enthalten in An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study Amsterdam volume:32 year:2016 number:3 pages:474-478 extent:5 |
format_phy_str_mv |
Article |
bklname |
Lösungen Flüssigkeiten |
institution |
findex.gbv.de |
topic_facet |
Varian Eclipse treatment planning system Flattening-filter-free beam energy Prostate cancer mARC rotational treatment |
dewey-raw |
530 |
isfreeaccess_bool |
false |
container_title |
An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study |
authorswithroles_txt_mv |
Bell, Katharina @@aut@@ Dzierma, Yvonne @@oth@@ Palm, Jan @@oth@@ Nuesken, Frank @@oth@@ Licht, Norbert @@oth@@ Rübe, Christian @@oth@@ |
publishDateDaySort_date |
2016-01-01T00:00:00Z |
hierarchy_top_id |
ELV003857336 |
dewey-sort |
3530 |
id |
ELV014439751 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV014439751</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623113955.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180602s2016 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.ejmp.2016.02.011</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2016018000005.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV014439751</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1120-1797(16)00521-4</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">530</subfield><subfield code="a">610</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">DNB</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">DNB</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">35.21</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Bell, Katharina</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2016</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">5</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Varian Eclipse treatment planning system</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Flattening-filter-free beam energy</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Prostate cancer</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">mARC rotational treatment</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dzierma, Yvonne</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Palm, Jan</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nuesken, Frank</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Licht, Norbert</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rübe, Christian</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier</subfield><subfield code="a">Almanassra, Ismail W. ELSEVIER</subfield><subfield code="t">An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study</subfield><subfield code="d">2019</subfield><subfield code="d">European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology</subfield><subfield code="g">Amsterdam</subfield><subfield code="w">(DE-627)ELV003857336</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:32</subfield><subfield code="g">year:2016</subfield><subfield code="g">number:3</subfield><subfield code="g">pages:474-478</subfield><subfield code="g">extent:5</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.ejmp.2016.02.011</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">35.21</subfield><subfield code="j">Lösungen</subfield><subfield code="j">Flüssigkeiten</subfield><subfield code="x">Physikalische Chemie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">32</subfield><subfield code="j">2016</subfield><subfield code="e">3</subfield><subfield code="h">474-478</subfield><subfield code="g">5</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">530</subfield></datafield></record></collection>
|
author |
Bell, Katharina |
spellingShingle |
Bell, Katharina ddc 530 ddc 610 ddc 540 bkl 35.21 Elsevier Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams |
authorStr |
Bell, Katharina |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV003857336 |
format |
electronic Article |
dewey-ones |
530 - Physics 610 - Medicine & health 540 - Chemistry & allied sciences |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
530 610 530 DNB 610 DNB 540 VZ 35.21 bkl mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment Elsevier |
topic |
ddc 530 ddc 610 ddc 540 bkl 35.21 Elsevier Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment |
topic_unstemmed |
ddc 530 ddc 610 ddc 540 bkl 35.21 Elsevier Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment |
topic_browse |
ddc 530 ddc 610 ddc 540 bkl 35.21 Elsevier Varian Eclipse treatment planning system Elsevier Flattening-filter-free beam energy Elsevier Prostate cancer Elsevier mARC rotational treatment |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
y d yd j p jp f n fn n l nl c r cr |
hierarchy_parent_title |
An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study |
hierarchy_parent_id |
ELV003857336 |
dewey-tens |
530 - Physics 610 - Medicine & health 540 - Chemistry |
hierarchy_top_title |
An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV003857336 |
title |
mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams |
ctrlnum |
(DE-627)ELV014439751 (ELSEVIER)S1120-1797(16)00521-4 |
title_full |
mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams |
author_sort |
Bell, Katharina |
journal |
An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study |
journalStr |
An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science 600 - Technology |
recordtype |
marc |
publishDateSort |
2016 |
contenttype_str_mv |
zzz |
container_start_page |
474 |
author_browse |
Bell, Katharina |
container_volume |
32 |
physical |
5 |
class |
530 610 530 DNB 610 DNB 540 VZ 35.21 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Bell, Katharina |
doi_str_mv |
10.1016/j.ejmp.2016.02.011 |
dewey-full |
530 610 540 |
title_sort |
marc prostate treatment planning with varian eclipse for flat vs. fff beams |
title_auth |
mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams |
abstract |
• Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. |
abstractGer |
• Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. |
abstract_unstemmed |
• Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA |
container_issue |
3 |
title_short |
mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams |
url |
https://doi.org/10.1016/j.ejmp.2016.02.011 |
remote_bool |
true |
author2 |
Dzierma, Yvonne Palm, Jan Nuesken, Frank Licht, Norbert Rübe, Christian |
author2Str |
Dzierma, Yvonne Palm, Jan Nuesken, Frank Licht, Norbert Rübe, Christian |
ppnlink |
ELV003857336 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth |
doi_str |
10.1016/j.ejmp.2016.02.011 |
up_date |
2024-07-06T21:33:51.308Z |
_version_ |
1803867003350417408 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV014439751</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623113955.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180602s2016 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.ejmp.2016.02.011</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2016018000005.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV014439751</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1120-1797(16)00521-4</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">530</subfield><subfield code="a">610</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">DNB</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">DNB</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">35.21</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Bell, Katharina</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">mARC prostate treatment planning with Varian Eclipse for flat vs. FFF beams</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2016</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">5</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• Highly conformal plans could be created with IMRT, mARC, flat and FFF energy. • mARC performs better regarding sparing of the bladder. • Treatment times could be markedly reduced by using mARC and FFF 7MV energy. • Scattered dose is also decreased by using mARC and FFF 7MV energy.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Varian Eclipse treatment planning system</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Flattening-filter-free beam energy</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Prostate cancer</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">mARC rotational treatment</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dzierma, Yvonne</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Palm, Jan</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nuesken, Frank</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Licht, Norbert</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rübe, Christian</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier</subfield><subfield code="a">Almanassra, Ismail W. ELSEVIER</subfield><subfield code="t">An experimental study on stability and thermal conductivity of water/CNTs nanofluids using different surfactants: A comparison study</subfield><subfield code="d">2019</subfield><subfield code="d">European journal of medical physics : an international journal devoted to the applications of physics to medicine and biology</subfield><subfield code="g">Amsterdam</subfield><subfield code="w">(DE-627)ELV003857336</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:32</subfield><subfield code="g">year:2016</subfield><subfield code="g">number:3</subfield><subfield code="g">pages:474-478</subfield><subfield code="g">extent:5</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.ejmp.2016.02.011</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">35.21</subfield><subfield code="j">Lösungen</subfield><subfield code="j">Flüssigkeiten</subfield><subfield code="x">Physikalische Chemie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">32</subfield><subfield code="j">2016</subfield><subfield code="e">3</subfield><subfield code="h">474-478</subfield><subfield code="g">5</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">530</subfield></datafield></record></collection>
|
score |
7.400361 |