Sensitivity of the diamagnetic sensor measurements of ITER to error sources and their compensation

• In the paper we discuss the sensitivity analysis for the measurement system of diamagnetic flux in the ITER tokamak. • Some compensation formulas have been tested to compensate the manufacturing errors, both for the sources and the sensors. • An estimation of the poloidal beta has been carried out...
Ausführliche Beschreibung

Gespeichert in:
Autor*in:

Fresa, R. [verfasserIn]

Albanese, R.

Arshad, S.

Coccorese, V.

de Magistris, M.

Minucci, S.

Pironti, A.

Quercia, A.

Rubinacci, G.

Vayakis, G.

Villone, F.

Format:

E-Artikel

Sprache:

Englisch

Erschienen:

2015

Schlagwörter:

Magnetic field measurement

Sensitivity analysis

Diamagnetic flux

Fusion reactors

Manufacturing testing

Error compensation formulas

Umfang:

9

Übergeordnetes Werk:

Enthalten in: CFD modelling of local scour around Tri-USAF in sand with different arrangements under steady current - Yang, Qi ELSEVIER, 2021, an international journal for fusion energy and technology devoted to experiments, theory, methods, and design, New York, NY [u.a.]

Übergeordnetes Werk:

volume:100 ; year:2015 ; pages:133-141 ; extent:9

Links:

Volltext

DOI / URN:

10.1016/j.fusengdes.2015.04.061

Katalog-ID:

ELV018578195