Compositional variance in extracted particulate matter using different filter extraction techniques
Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols...
Ausführliche Beschreibung
Autor*in: |
Bein, K.J. [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2015transfer abstract |
---|
Schlagwörter: |
---|
Umfang: |
11 |
---|
Übergeordnetes Werk: |
Enthalten in: The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction - Nassar, M.K. ELSEVIER, 2021, Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:107 ; year:2015 ; pages:24-34 ; extent:11 |
Links: |
---|
DOI / URN: |
10.1016/j.atmosenv.2015.02.026 |
---|
Katalog-ID: |
ELV018796133 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV018796133 | ||
003 | DE-627 | ||
005 | 20230625124629.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180602s2015 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.atmosenv.2015.02.026 |2 doi | |
028 | 5 | 2 | |a GBV00000000000190A.pica |
035 | |a (DE-627)ELV018796133 | ||
035 | |a (ELSEVIER)S1352-2310(15)00145-4 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | |a 550 |a 690 | |
082 | 0 | 4 | |a 550 |q DE-600 |
082 | 0 | 4 | |a 690 |q DE-600 |
082 | 0 | 4 | |a 610 |q VZ |
084 | |a 44.65 |2 bkl | ||
100 | 1 | |a Bein, K.J. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Compositional variance in extracted particulate matter using different filter extraction techniques |
264 | 1 | |c 2015transfer abstract | |
300 | |a 11 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. | ||
520 | |a Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. | ||
650 | 7 | |a Particulate matter composition |2 Elsevier | |
650 | 7 | |a Filter sampling |2 Elsevier | |
650 | 7 | |a Particulate matter extract |2 Elsevier | |
650 | 7 | |a Filter extraction |2 Elsevier | |
650 | 7 | |a Compositional bias |2 Elsevier | |
700 | 1 | |a Wexler, A.S. |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Nassar, M.K. ELSEVIER |t The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction |d 2021 |g Amsterdam [u.a.] |w (DE-627)ELV00656139X |
773 | 1 | 8 | |g volume:107 |g year:2015 |g pages:24-34 |g extent:11 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.atmosenv.2015.02.026 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 44.65 |j Chirurgie |q VZ |
951 | |a AR | ||
952 | |d 107 |j 2015 |h 24-34 |g 11 | ||
953 | |2 045F |a 550 |
author_variant |
k b kb |
---|---|
matchkey_str |
beinkjwexleras:2015----:opstoavracietatdatcltmteuigifrnfl |
hierarchy_sort_str |
2015transfer abstract |
bklnumber |
44.65 |
publishDate |
2015 |
allfields |
10.1016/j.atmosenv.2015.02.026 doi GBV00000000000190A.pica (DE-627)ELV018796133 (ELSEVIER)S1352-2310(15)00145-4 DE-627 ger DE-627 rakwb eng 550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl Bein, K.J. verfasserin aut Compositional variance in extracted particulate matter using different filter extraction techniques 2015transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Elsevier Wexler, A.S. oth Enthalten in Elsevier Science Nassar, M.K. ELSEVIER The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction 2021 Amsterdam [u.a.] (DE-627)ELV00656139X volume:107 year:2015 pages:24-34 extent:11 https://doi.org/10.1016/j.atmosenv.2015.02.026 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.65 Chirurgie VZ AR 107 2015 24-34 11 045F 550 |
spelling |
10.1016/j.atmosenv.2015.02.026 doi GBV00000000000190A.pica (DE-627)ELV018796133 (ELSEVIER)S1352-2310(15)00145-4 DE-627 ger DE-627 rakwb eng 550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl Bein, K.J. verfasserin aut Compositional variance in extracted particulate matter using different filter extraction techniques 2015transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Elsevier Wexler, A.S. oth Enthalten in Elsevier Science Nassar, M.K. ELSEVIER The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction 2021 Amsterdam [u.a.] (DE-627)ELV00656139X volume:107 year:2015 pages:24-34 extent:11 https://doi.org/10.1016/j.atmosenv.2015.02.026 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.65 Chirurgie VZ AR 107 2015 24-34 11 045F 550 |
allfields_unstemmed |
10.1016/j.atmosenv.2015.02.026 doi GBV00000000000190A.pica (DE-627)ELV018796133 (ELSEVIER)S1352-2310(15)00145-4 DE-627 ger DE-627 rakwb eng 550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl Bein, K.J. verfasserin aut Compositional variance in extracted particulate matter using different filter extraction techniques 2015transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Elsevier Wexler, A.S. oth Enthalten in Elsevier Science Nassar, M.K. ELSEVIER The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction 2021 Amsterdam [u.a.] (DE-627)ELV00656139X volume:107 year:2015 pages:24-34 extent:11 https://doi.org/10.1016/j.atmosenv.2015.02.026 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.65 Chirurgie VZ AR 107 2015 24-34 11 045F 550 |
allfieldsGer |
10.1016/j.atmosenv.2015.02.026 doi GBV00000000000190A.pica (DE-627)ELV018796133 (ELSEVIER)S1352-2310(15)00145-4 DE-627 ger DE-627 rakwb eng 550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl Bein, K.J. verfasserin aut Compositional variance in extracted particulate matter using different filter extraction techniques 2015transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Elsevier Wexler, A.S. oth Enthalten in Elsevier Science Nassar, M.K. ELSEVIER The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction 2021 Amsterdam [u.a.] (DE-627)ELV00656139X volume:107 year:2015 pages:24-34 extent:11 https://doi.org/10.1016/j.atmosenv.2015.02.026 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.65 Chirurgie VZ AR 107 2015 24-34 11 045F 550 |
allfieldsSound |
10.1016/j.atmosenv.2015.02.026 doi GBV00000000000190A.pica (DE-627)ELV018796133 (ELSEVIER)S1352-2310(15)00145-4 DE-627 ger DE-627 rakwb eng 550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl Bein, K.J. verfasserin aut Compositional variance in extracted particulate matter using different filter extraction techniques 2015transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Elsevier Wexler, A.S. oth Enthalten in Elsevier Science Nassar, M.K. ELSEVIER The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction 2021 Amsterdam [u.a.] (DE-627)ELV00656139X volume:107 year:2015 pages:24-34 extent:11 https://doi.org/10.1016/j.atmosenv.2015.02.026 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.65 Chirurgie VZ AR 107 2015 24-34 11 045F 550 |
language |
English |
source |
Enthalten in The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction Amsterdam [u.a.] volume:107 year:2015 pages:24-34 extent:11 |
sourceStr |
Enthalten in The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction Amsterdam [u.a.] volume:107 year:2015 pages:24-34 extent:11 |
format_phy_str_mv |
Article |
bklname |
Chirurgie |
institution |
findex.gbv.de |
topic_facet |
Particulate matter composition Filter sampling Particulate matter extract Filter extraction Compositional bias |
dewey-raw |
550 |
isfreeaccess_bool |
false |
container_title |
The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction |
authorswithroles_txt_mv |
Bein, K.J. @@aut@@ Wexler, A.S. @@oth@@ |
publishDateDaySort_date |
2015-01-01T00:00:00Z |
hierarchy_top_id |
ELV00656139X |
dewey-sort |
3550 |
id |
ELV018796133 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV018796133</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230625124629.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180602s2015 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.atmosenv.2015.02.026</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBV00000000000190A.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV018796133</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1352-2310(15)00145-4</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">550</subfield><subfield code="a">690</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">550</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">690</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.65</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Bein, K.J.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Compositional variance in extracted particulate matter using different filter extraction techniques</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2015transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">11</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies.</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Particulate matter composition</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Filter sampling</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Particulate matter extract</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Filter extraction</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Compositional bias</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wexler, A.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Nassar, M.K. ELSEVIER</subfield><subfield code="t">The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction</subfield><subfield code="d">2021</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV00656139X</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:107</subfield><subfield code="g">year:2015</subfield><subfield code="g">pages:24-34</subfield><subfield code="g">extent:11</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.atmosenv.2015.02.026</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.65</subfield><subfield code="j">Chirurgie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">107</subfield><subfield code="j">2015</subfield><subfield code="h">24-34</subfield><subfield code="g">11</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">550</subfield></datafield></record></collection>
|
author |
Bein, K.J. |
spellingShingle |
Bein, K.J. ddc 550 ddc 690 ddc 610 bkl 44.65 Elsevier Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Compositional variance in extracted particulate matter using different filter extraction techniques |
authorStr |
Bein, K.J. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV00656139X |
format |
electronic Article |
dewey-ones |
550 - Earth sciences 690 - Buildings 610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl Compositional variance in extracted particulate matter using different filter extraction techniques Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias Elsevier |
topic |
ddc 550 ddc 690 ddc 610 bkl 44.65 Elsevier Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias |
topic_unstemmed |
ddc 550 ddc 690 ddc 610 bkl 44.65 Elsevier Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias |
topic_browse |
ddc 550 ddc 690 ddc 610 bkl 44.65 Elsevier Particulate matter composition Elsevier Filter sampling Elsevier Particulate matter extract Elsevier Filter extraction Elsevier Compositional bias |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
a w aw |
hierarchy_parent_title |
The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction |
hierarchy_parent_id |
ELV00656139X |
dewey-tens |
550 - Earth sciences & geology 690 - Building & construction 610 - Medicine & health |
hierarchy_top_title |
The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV00656139X |
title |
Compositional variance in extracted particulate matter using different filter extraction techniques |
ctrlnum |
(DE-627)ELV018796133 (ELSEVIER)S1352-2310(15)00145-4 |
title_full |
Compositional variance in extracted particulate matter using different filter extraction techniques |
author_sort |
Bein, K.J. |
journal |
The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction |
journalStr |
The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science 600 - Technology |
recordtype |
marc |
publishDateSort |
2015 |
contenttype_str_mv |
zzz |
container_start_page |
24 |
author_browse |
Bein, K.J. |
container_volume |
107 |
physical |
11 |
class |
550 690 550 DE-600 690 DE-600 610 VZ 44.65 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Bein, K.J. |
doi_str_mv |
10.1016/j.atmosenv.2015.02.026 |
dewey-full |
550 690 610 |
title_sort |
compositional variance in extracted particulate matter using different filter extraction techniques |
title_auth |
Compositional variance in extracted particulate matter using different filter extraction techniques |
abstract |
Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. |
abstractGer |
Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. |
abstract_unstemmed |
Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA |
title_short |
Compositional variance in extracted particulate matter using different filter extraction techniques |
url |
https://doi.org/10.1016/j.atmosenv.2015.02.026 |
remote_bool |
true |
author2 |
Wexler, A.S. |
author2Str |
Wexler, A.S. |
ppnlink |
ELV00656139X |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth |
doi_str |
10.1016/j.atmosenv.2015.02.026 |
up_date |
2024-07-06T19:43:39.196Z |
_version_ |
1803860070048464896 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV018796133</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230625124629.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180602s2015 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.atmosenv.2015.02.026</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBV00000000000190A.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV018796133</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S1352-2310(15)00145-4</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">550</subfield><subfield code="a">690</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">550</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">690</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.65</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Bein, K.J.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Compositional variance in extracted particulate matter using different filter extraction techniques</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2015transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">11</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies.</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Collection and subsequent extraction of particulate matter (PM) from filter substrates is a common requirement for in vivo and in vitro toxicological studies, as well as chemical analyses such as ion chromatography and inductively coupled plasma mass spectrometry. Several filter extraction protocols exist and different laboratories employ different methods, potentially biasing inter-study comparisons. Previous studies have shown significant differences in extraction efficiency between techniques and identified the relevant extraction artifacts. However, a comprehensive inter-comparison of different methods based on the chemical composition of the extracted PM has never been conducted. In the current study, an exhaustive suite of chemical analyses is performed on PM extracted from glass micro-fiber filters using techniques commonly employed in different laboratories: Multi-solvent extraction (MSE) and spin-down extraction (SDE). PM samples were collected simultaneously during field studies conducted in an urban and rural setting using a high-volume PM2.5 sampler. Results show remarkable compositional variance between the PM extracts for all chemical components analyzed, including metals, water soluble ions, polycyclic aromatic hydrocarbons, non-aromatic organics, elemental carbon and organic carbon. Mass closure was greater than 90% for MSE but deviated substantially for SDE. Detailed retrospective gravimetric analysis of archived SDE samples revealed that a process-based loss of PM mass is the root cause of the differences. These losses are shown to be compositionally biased, both externally between different PM mixtures and internally within a given PM mixture. In combination, the results of this study are the first to demonstrate (i) an exhaustive chemical characterization of a single PM extract, (ii) the significance of directly characterizing the extracted PM used in toxicological studies, (iii) the existence of substantial compositional biases between different filter extraction techniques and (iv) the importance of standardizing filter extraction objectives and procedures to avoid introducing study bias into toxicological studies.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Particulate matter composition</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Filter sampling</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Particulate matter extract</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Filter extraction</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Compositional bias</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wexler, A.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Nassar, M.K. ELSEVIER</subfield><subfield code="t">The internal pudendal artery turnover (IPAT) flap: A new, simple and reliable technique for perineal reconstruction</subfield><subfield code="d">2021</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV00656139X</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:107</subfield><subfield code="g">year:2015</subfield><subfield code="g">pages:24-34</subfield><subfield code="g">extent:11</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.atmosenv.2015.02.026</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.65</subfield><subfield code="j">Chirurgie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">107</subfield><subfield code="j">2015</subfield><subfield code="h">24-34</subfield><subfield code="g">11</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">550</subfield></datafield></record></collection>
|
score |
7.399805 |