Compressive sampling-based strategy for enhancing ADCs resolution
• We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained.
Autor*in: |
Baccigalupi, Aldo [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2014 |
---|
Schlagwörter: |
---|
Umfang: |
9 |
---|
Übergeordnetes Werk: |
Enthalten in: High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level - Kwon, Yeong Min ELSEVIER, 2022, journal of the International Measurement Confederation (IMEKO), Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:56 ; year:2014 ; pages:95-103 ; extent:9 |
Links: |
---|
DOI / URN: |
10.1016/j.measurement.2014.06.006 |
---|
Katalog-ID: |
ELV022632336 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV022632336 | ||
003 | DE-627 | ||
005 | 20230623164402.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180603s2014 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.measurement.2014.06.006 |2 doi | |
028 | 5 | 2 | |a GBVA2014008000030.pica |
035 | |a (DE-627)ELV022632336 | ||
035 | |a (ELSEVIER)S0263-2241(14)00267-X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | |a 660 | |
082 | 0 | 4 | |a 660 |q DE-600 |
082 | 0 | 4 | |a 530 |a 620 |q VZ |
084 | |a 50.22 |2 bkl | ||
084 | |a 35.07 |2 bkl | ||
100 | 1 | |a Baccigalupi, Aldo |e verfasserin |4 aut | |
245 | 1 | 0 | |a Compressive sampling-based strategy for enhancing ADCs resolution |
264 | 1 | |c 2014 | |
300 | |a 9 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a • We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. | ||
650 | 7 | |a Penalty function |2 Elsevier | |
650 | 7 | |a Sampling frequency increase |2 Elsevier | |
650 | 7 | |a ADC resolution enhancement |2 Elsevier | |
650 | 7 | |a Compressive sampling |2 Elsevier | |
650 | 7 | |a Optimized multisine |2 Elsevier | |
700 | 1 | |a D’Arco, Mauro |4 oth | |
700 | 1 | |a Liccardo, Annalisa |4 oth | |
700 | 1 | |a Schiano Lo Moriello, Rosario |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Kwon, Yeong Min ELSEVIER |t High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level |d 2022 |d journal of the International Measurement Confederation (IMEKO) |g Amsterdam [u.a.] |w (DE-627)ELV008789606 |
773 | 1 | 8 | |g volume:56 |g year:2014 |g pages:95-103 |g extent:9 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.measurement.2014.06.006 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 50.22 |j Sensorik |q VZ |
936 | b | k | |a 35.07 |j Chemisches Labor |j chemische Methoden |q VZ |
951 | |a AR | ||
952 | |d 56 |j 2014 |h 95-103 |g 9 | ||
953 | |2 045F |a 660 |
author_variant |
a b ab |
---|---|
matchkey_str |
baccigalupialdodarcomauroliccardoannalis:2014----:opesvsmlnbsdtaeyoehni |
hierarchy_sort_str |
2014 |
bklnumber |
50.22 35.07 |
publishDate |
2014 |
allfields |
10.1016/j.measurement.2014.06.006 doi GBVA2014008000030.pica (DE-627)ELV022632336 (ELSEVIER)S0263-2241(14)00267-X DE-627 ger DE-627 rakwb eng 660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl Baccigalupi, Aldo verfasserin aut Compressive sampling-based strategy for enhancing ADCs resolution 2014 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Elsevier D’Arco, Mauro oth Liccardo, Annalisa oth Schiano Lo Moriello, Rosario oth Enthalten in Elsevier Science Kwon, Yeong Min ELSEVIER High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level 2022 journal of the International Measurement Confederation (IMEKO) Amsterdam [u.a.] (DE-627)ELV008789606 volume:56 year:2014 pages:95-103 extent:9 https://doi.org/10.1016/j.measurement.2014.06.006 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 50.22 Sensorik VZ 35.07 Chemisches Labor chemische Methoden VZ AR 56 2014 95-103 9 045F 660 |
spelling |
10.1016/j.measurement.2014.06.006 doi GBVA2014008000030.pica (DE-627)ELV022632336 (ELSEVIER)S0263-2241(14)00267-X DE-627 ger DE-627 rakwb eng 660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl Baccigalupi, Aldo verfasserin aut Compressive sampling-based strategy for enhancing ADCs resolution 2014 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Elsevier D’Arco, Mauro oth Liccardo, Annalisa oth Schiano Lo Moriello, Rosario oth Enthalten in Elsevier Science Kwon, Yeong Min ELSEVIER High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level 2022 journal of the International Measurement Confederation (IMEKO) Amsterdam [u.a.] (DE-627)ELV008789606 volume:56 year:2014 pages:95-103 extent:9 https://doi.org/10.1016/j.measurement.2014.06.006 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 50.22 Sensorik VZ 35.07 Chemisches Labor chemische Methoden VZ AR 56 2014 95-103 9 045F 660 |
allfields_unstemmed |
10.1016/j.measurement.2014.06.006 doi GBVA2014008000030.pica (DE-627)ELV022632336 (ELSEVIER)S0263-2241(14)00267-X DE-627 ger DE-627 rakwb eng 660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl Baccigalupi, Aldo verfasserin aut Compressive sampling-based strategy for enhancing ADCs resolution 2014 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Elsevier D’Arco, Mauro oth Liccardo, Annalisa oth Schiano Lo Moriello, Rosario oth Enthalten in Elsevier Science Kwon, Yeong Min ELSEVIER High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level 2022 journal of the International Measurement Confederation (IMEKO) Amsterdam [u.a.] (DE-627)ELV008789606 volume:56 year:2014 pages:95-103 extent:9 https://doi.org/10.1016/j.measurement.2014.06.006 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 50.22 Sensorik VZ 35.07 Chemisches Labor chemische Methoden VZ AR 56 2014 95-103 9 045F 660 |
allfieldsGer |
10.1016/j.measurement.2014.06.006 doi GBVA2014008000030.pica (DE-627)ELV022632336 (ELSEVIER)S0263-2241(14)00267-X DE-627 ger DE-627 rakwb eng 660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl Baccigalupi, Aldo verfasserin aut Compressive sampling-based strategy for enhancing ADCs resolution 2014 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Elsevier D’Arco, Mauro oth Liccardo, Annalisa oth Schiano Lo Moriello, Rosario oth Enthalten in Elsevier Science Kwon, Yeong Min ELSEVIER High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level 2022 journal of the International Measurement Confederation (IMEKO) Amsterdam [u.a.] (DE-627)ELV008789606 volume:56 year:2014 pages:95-103 extent:9 https://doi.org/10.1016/j.measurement.2014.06.006 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 50.22 Sensorik VZ 35.07 Chemisches Labor chemische Methoden VZ AR 56 2014 95-103 9 045F 660 |
allfieldsSound |
10.1016/j.measurement.2014.06.006 doi GBVA2014008000030.pica (DE-627)ELV022632336 (ELSEVIER)S0263-2241(14)00267-X DE-627 ger DE-627 rakwb eng 660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl Baccigalupi, Aldo verfasserin aut Compressive sampling-based strategy for enhancing ADCs resolution 2014 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Elsevier D’Arco, Mauro oth Liccardo, Annalisa oth Schiano Lo Moriello, Rosario oth Enthalten in Elsevier Science Kwon, Yeong Min ELSEVIER High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level 2022 journal of the International Measurement Confederation (IMEKO) Amsterdam [u.a.] (DE-627)ELV008789606 volume:56 year:2014 pages:95-103 extent:9 https://doi.org/10.1016/j.measurement.2014.06.006 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 50.22 Sensorik VZ 35.07 Chemisches Labor chemische Methoden VZ AR 56 2014 95-103 9 045F 660 |
language |
English |
source |
Enthalten in High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level Amsterdam [u.a.] volume:56 year:2014 pages:95-103 extent:9 |
sourceStr |
Enthalten in High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level Amsterdam [u.a.] volume:56 year:2014 pages:95-103 extent:9 |
format_phy_str_mv |
Article |
bklname |
Sensorik Chemisches Labor chemische Methoden |
institution |
findex.gbv.de |
topic_facet |
Penalty function Sampling frequency increase ADC resolution enhancement Compressive sampling Optimized multisine |
dewey-raw |
660 |
isfreeaccess_bool |
false |
container_title |
High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level |
authorswithroles_txt_mv |
Baccigalupi, Aldo @@aut@@ D’Arco, Mauro @@oth@@ Liccardo, Annalisa @@oth@@ Schiano Lo Moriello, Rosario @@oth@@ |
publishDateDaySort_date |
2014-01-01T00:00:00Z |
hierarchy_top_id |
ELV008789606 |
dewey-sort |
3660 |
id |
ELV022632336 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV022632336</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623164402.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180603s2014 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.measurement.2014.06.006</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2014008000030.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV022632336</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0263-2241(14)00267-X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">660</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">660</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">50.22</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">35.07</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Baccigalupi, Aldo</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Compressive sampling-based strategy for enhancing ADCs resolution</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2014</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">9</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Penalty function</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Sampling frequency increase</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">ADC resolution enhancement</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Compressive sampling</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Optimized multisine</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">D’Arco, Mauro</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Liccardo, Annalisa</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schiano Lo Moriello, Rosario</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Kwon, Yeong Min ELSEVIER</subfield><subfield code="t">High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level</subfield><subfield code="d">2022</subfield><subfield code="d">journal of the International Measurement Confederation (IMEKO)</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV008789606</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:56</subfield><subfield code="g">year:2014</subfield><subfield code="g">pages:95-103</subfield><subfield code="g">extent:9</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.measurement.2014.06.006</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">50.22</subfield><subfield code="j">Sensorik</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">35.07</subfield><subfield code="j">Chemisches Labor</subfield><subfield code="j">chemische Methoden</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">56</subfield><subfield code="j">2014</subfield><subfield code="h">95-103</subfield><subfield code="g">9</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">660</subfield></datafield></record></collection>
|
author |
Baccigalupi, Aldo |
spellingShingle |
Baccigalupi, Aldo ddc 660 ddc 530 bkl 50.22 bkl 35.07 Elsevier Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Compressive sampling-based strategy for enhancing ADCs resolution |
authorStr |
Baccigalupi, Aldo |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV008789606 |
format |
electronic Article |
dewey-ones |
660 - Chemical engineering 530 - Physics 620 - Engineering & allied operations |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl Compressive sampling-based strategy for enhancing ADCs resolution Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine Elsevier |
topic |
ddc 660 ddc 530 bkl 50.22 bkl 35.07 Elsevier Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine |
topic_unstemmed |
ddc 660 ddc 530 bkl 50.22 bkl 35.07 Elsevier Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine |
topic_browse |
ddc 660 ddc 530 bkl 50.22 bkl 35.07 Elsevier Penalty function Elsevier Sampling frequency increase Elsevier ADC resolution enhancement Elsevier Compressive sampling Elsevier Optimized multisine |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
m d md a l al l m r s lmr lmrs |
hierarchy_parent_title |
High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level |
hierarchy_parent_id |
ELV008789606 |
dewey-tens |
660 - Chemical engineering 530 - Physics 620 - Engineering |
hierarchy_top_title |
High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV008789606 |
title |
Compressive sampling-based strategy for enhancing ADCs resolution |
ctrlnum |
(DE-627)ELV022632336 (ELSEVIER)S0263-2241(14)00267-X |
title_full |
Compressive sampling-based strategy for enhancing ADCs resolution |
author_sort |
Baccigalupi, Aldo |
journal |
High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level |
journalStr |
High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology 500 - Science |
recordtype |
marc |
publishDateSort |
2014 |
contenttype_str_mv |
zzz |
container_start_page |
95 |
author_browse |
Baccigalupi, Aldo |
container_volume |
56 |
physical |
9 |
class |
660 660 DE-600 530 620 VZ 50.22 bkl 35.07 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Baccigalupi, Aldo |
doi_str_mv |
10.1016/j.measurement.2014.06.006 |
dewey-full |
660 530 620 |
title_sort |
compressive sampling-based strategy for enhancing adcs resolution |
title_auth |
Compressive sampling-based strategy for enhancing ADCs resolution |
abstract |
• We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. |
abstractGer |
• We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. |
abstract_unstemmed |
• We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA |
title_short |
Compressive sampling-based strategy for enhancing ADCs resolution |
url |
https://doi.org/10.1016/j.measurement.2014.06.006 |
remote_bool |
true |
author2 |
D’Arco, Mauro Liccardo, Annalisa Schiano Lo Moriello, Rosario |
author2Str |
D’Arco, Mauro Liccardo, Annalisa Schiano Lo Moriello, Rosario |
ppnlink |
ELV008789606 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth |
doi_str |
10.1016/j.measurement.2014.06.006 |
up_date |
2024-07-06T16:46:05.014Z |
_version_ |
1803848898332065792 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV022632336</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623164402.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180603s2014 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.measurement.2014.06.006</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2014008000030.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV022632336</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0263-2241(14)00267-X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">660</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">660</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="a">620</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">50.22</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">35.07</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Baccigalupi, Aldo</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Compressive sampling-based strategy for enhancing ADCs resolution</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2014</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">9</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• We propose a CS-based acquisition for increasing ADC equivalent sampling frequency. • By means of oversampling and filtering, the SNR of the reconstructed signal is increased. • A penalty function is exploited for shaping the ADC noise. • A resolution increment of about 3bits is obtained.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Penalty function</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Sampling frequency increase</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">ADC resolution enhancement</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Compressive sampling</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Optimized multisine</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">D’Arco, Mauro</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Liccardo, Annalisa</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schiano Lo Moriello, Rosario</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Kwon, Yeong Min ELSEVIER</subfield><subfield code="t">High-performance and self-calibrating multi-gas sensor interface to trace multiple gas species with sub-ppm level</subfield><subfield code="d">2022</subfield><subfield code="d">journal of the International Measurement Confederation (IMEKO)</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV008789606</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:56</subfield><subfield code="g">year:2014</subfield><subfield code="g">pages:95-103</subfield><subfield code="g">extent:9</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.measurement.2014.06.006</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">50.22</subfield><subfield code="j">Sensorik</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">35.07</subfield><subfield code="j">Chemisches Labor</subfield><subfield code="j">chemische Methoden</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">56</subfield><subfield code="j">2014</subfield><subfield code="h">95-103</subfield><subfield code="g">9</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">660</subfield></datafield></record></collection>
|
score |
7.402648 |