A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions
• A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm...
Ausführliche Beschreibung
Autor*in: |
Yeung, Ryan Shun-cheung [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2017 |
---|
Schlagwörter: |
---|
Umfang: |
14 |
---|
Übergeordnetes Werk: |
Enthalten in: Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? - Ji, Yanhu ELSEVIER, 2022, the official journal of the International Solar Energy Society, Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:141 ; year:2017 ; day:1 ; month:01 ; pages:145-158 ; extent:14 |
Links: |
---|
DOI / URN: |
10.1016/j.solener.2016.11.017 |
---|
Katalog-ID: |
ELV025693301 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV025693301 | ||
003 | DE-627 | ||
005 | 20230623181511.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180603s2017 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.solener.2016.11.017 |2 doi | |
028 | 5 | 2 | |a GBVA2017023000003.pica |
035 | |a (DE-627)ELV025693301 | ||
035 | |a (ELSEVIER)S0038-092X(16)30532-1 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | |a 530 | |
082 | 0 | 4 | |a 530 |q DE-600 |
082 | 0 | 4 | |a 333.7 |a 610 |q VZ |
084 | |a 44.13 |2 bkl | ||
100 | 1 | |a Yeung, Ryan Shun-cheung |e verfasserin |4 aut | |
245 | 1 | 0 | |a A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions |
264 | 1 | |c 2017 | |
300 | |a 14 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a • A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. | ||
650 | 7 | |a Photovoltaic systems |2 Elsevier | |
650 | 7 | |a MPPT |2 Elsevier | |
650 | 7 | |a Global MPPT |2 Elsevier | |
650 | 7 | |a Solar panels |2 Elsevier | |
700 | 1 | |a Chung, Henry Shu-hung |4 oth | |
700 | 1 | |a Tse, Norman Chung-fai |4 oth | |
700 | 1 | |a Chuang, Steve Tzu-hsiung |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Ji, Yanhu ELSEVIER |t Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? |d 2022 |d the official journal of the International Solar Energy Society |g Amsterdam [u.a.] |w (DE-627)ELV007630522 |
773 | 1 | 8 | |g volume:141 |g year:2017 |g day:1 |g month:01 |g pages:145-158 |g extent:14 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.solener.2016.11.017 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
936 | b | k | |a 44.13 |j Medizinische Ökologie |q VZ |
951 | |a AR | ||
952 | |d 141 |j 2017 |b 1 |c 0101 |h 145-158 |g 14 | ||
953 | |2 045F |a 530 |
author_variant |
r s c y rsc rscy |
---|---|
matchkey_str |
yeungryanshuncheungchunghenryshuhungtsen:2017----:goampagrtmoeitnpssemtgtnsbpi |
hierarchy_sort_str |
2017 |
bklnumber |
44.13 |
publishDate |
2017 |
allfields |
10.1016/j.solener.2016.11.017 doi GBVA2017023000003.pica (DE-627)ELV025693301 (ELSEVIER)S0038-092X(16)30532-1 DE-627 ger DE-627 rakwb eng 530 530 DE-600 333.7 610 VZ 44.13 bkl Yeung, Ryan Shun-cheung verfasserin aut A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions 2017 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels Elsevier Chung, Henry Shu-hung oth Tse, Norman Chung-fai oth Chuang, Steve Tzu-hsiung oth Enthalten in Elsevier Science Ji, Yanhu ELSEVIER Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? 2022 the official journal of the International Solar Energy Society Amsterdam [u.a.] (DE-627)ELV007630522 volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 https://doi.org/10.1016/j.solener.2016.11.017 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 44.13 Medizinische Ökologie VZ AR 141 2017 1 0101 145-158 14 045F 530 |
spelling |
10.1016/j.solener.2016.11.017 doi GBVA2017023000003.pica (DE-627)ELV025693301 (ELSEVIER)S0038-092X(16)30532-1 DE-627 ger DE-627 rakwb eng 530 530 DE-600 333.7 610 VZ 44.13 bkl Yeung, Ryan Shun-cheung verfasserin aut A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions 2017 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels Elsevier Chung, Henry Shu-hung oth Tse, Norman Chung-fai oth Chuang, Steve Tzu-hsiung oth Enthalten in Elsevier Science Ji, Yanhu ELSEVIER Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? 2022 the official journal of the International Solar Energy Society Amsterdam [u.a.] (DE-627)ELV007630522 volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 https://doi.org/10.1016/j.solener.2016.11.017 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 44.13 Medizinische Ökologie VZ AR 141 2017 1 0101 145-158 14 045F 530 |
allfields_unstemmed |
10.1016/j.solener.2016.11.017 doi GBVA2017023000003.pica (DE-627)ELV025693301 (ELSEVIER)S0038-092X(16)30532-1 DE-627 ger DE-627 rakwb eng 530 530 DE-600 333.7 610 VZ 44.13 bkl Yeung, Ryan Shun-cheung verfasserin aut A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions 2017 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels Elsevier Chung, Henry Shu-hung oth Tse, Norman Chung-fai oth Chuang, Steve Tzu-hsiung oth Enthalten in Elsevier Science Ji, Yanhu ELSEVIER Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? 2022 the official journal of the International Solar Energy Society Amsterdam [u.a.] (DE-627)ELV007630522 volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 https://doi.org/10.1016/j.solener.2016.11.017 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 44.13 Medizinische Ökologie VZ AR 141 2017 1 0101 145-158 14 045F 530 |
allfieldsGer |
10.1016/j.solener.2016.11.017 doi GBVA2017023000003.pica (DE-627)ELV025693301 (ELSEVIER)S0038-092X(16)30532-1 DE-627 ger DE-627 rakwb eng 530 530 DE-600 333.7 610 VZ 44.13 bkl Yeung, Ryan Shun-cheung verfasserin aut A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions 2017 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels Elsevier Chung, Henry Shu-hung oth Tse, Norman Chung-fai oth Chuang, Steve Tzu-hsiung oth Enthalten in Elsevier Science Ji, Yanhu ELSEVIER Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? 2022 the official journal of the International Solar Energy Society Amsterdam [u.a.] (DE-627)ELV007630522 volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 https://doi.org/10.1016/j.solener.2016.11.017 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 44.13 Medizinische Ökologie VZ AR 141 2017 1 0101 145-158 14 045F 530 |
allfieldsSound |
10.1016/j.solener.2016.11.017 doi GBVA2017023000003.pica (DE-627)ELV025693301 (ELSEVIER)S0038-092X(16)30532-1 DE-627 ger DE-627 rakwb eng 530 530 DE-600 333.7 610 VZ 44.13 bkl Yeung, Ryan Shun-cheung verfasserin aut A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions 2017 14 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels Elsevier Chung, Henry Shu-hung oth Tse, Norman Chung-fai oth Chuang, Steve Tzu-hsiung oth Enthalten in Elsevier Science Ji, Yanhu ELSEVIER Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? 2022 the official journal of the International Solar Energy Society Amsterdam [u.a.] (DE-627)ELV007630522 volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 https://doi.org/10.1016/j.solener.2016.11.017 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 44.13 Medizinische Ökologie VZ AR 141 2017 1 0101 145-158 14 045F 530 |
language |
English |
source |
Enthalten in Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? Amsterdam [u.a.] volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 |
sourceStr |
Enthalten in Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? Amsterdam [u.a.] volume:141 year:2017 day:1 month:01 pages:145-158 extent:14 |
format_phy_str_mv |
Article |
bklname |
Medizinische Ökologie |
institution |
findex.gbv.de |
topic_facet |
Photovoltaic systems MPPT Global MPPT Solar panels |
dewey-raw |
530 |
isfreeaccess_bool |
false |
container_title |
Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? |
authorswithroles_txt_mv |
Yeung, Ryan Shun-cheung @@aut@@ Chung, Henry Shu-hung @@oth@@ Tse, Norman Chung-fai @@oth@@ Chuang, Steve Tzu-hsiung @@oth@@ |
publishDateDaySort_date |
2017-01-01T00:00:00Z |
hierarchy_top_id |
ELV007630522 |
dewey-sort |
3530 |
id |
ELV025693301 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV025693301</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623181511.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180603s2017 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.solener.2016.11.017</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2017023000003.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV025693301</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0038-092X(16)30532-1</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">530</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">333.7</subfield><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.13</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Yeung, Ryan Shun-cheung</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2017</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">14</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Photovoltaic systems</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">MPPT</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Global MPPT</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Solar panels</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chung, Henry Shu-hung</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tse, Norman Chung-fai</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chuang, Steve Tzu-hsiung</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Ji, Yanhu ELSEVIER</subfield><subfield code="t">Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups?</subfield><subfield code="d">2022</subfield><subfield code="d">the official journal of the International Solar Energy Society</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV007630522</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:141</subfield><subfield code="g">year:2017</subfield><subfield code="g">day:1</subfield><subfield code="g">month:01</subfield><subfield code="g">pages:145-158</subfield><subfield code="g">extent:14</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.solener.2016.11.017</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.13</subfield><subfield code="j">Medizinische Ökologie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">141</subfield><subfield code="j">2017</subfield><subfield code="b">1</subfield><subfield code="c">0101</subfield><subfield code="h">145-158</subfield><subfield code="g">14</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">530</subfield></datafield></record></collection>
|
author |
Yeung, Ryan Shun-cheung |
spellingShingle |
Yeung, Ryan Shun-cheung ddc 530 ddc 333.7 bkl 44.13 Elsevier Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions |
authorStr |
Yeung, Ryan Shun-cheung |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV007630522 |
format |
electronic Article |
dewey-ones |
530 - Physics 333 - Economics of land & energy 610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
530 530 DE-600 333.7 610 VZ 44.13 bkl A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels Elsevier |
topic |
ddc 530 ddc 333.7 bkl 44.13 Elsevier Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels |
topic_unstemmed |
ddc 530 ddc 333.7 bkl 44.13 Elsevier Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels |
topic_browse |
ddc 530 ddc 333.7 bkl 44.13 Elsevier Photovoltaic systems Elsevier MPPT Elsevier Global MPPT Elsevier Solar panels |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
h s h c hsh hshc n c f t ncf ncft s t h c sth sthc |
hierarchy_parent_title |
Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? |
hierarchy_parent_id |
ELV007630522 |
dewey-tens |
530 - Physics 330 - Economics 610 - Medicine & health |
hierarchy_top_title |
Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV007630522 |
title |
A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions |
ctrlnum |
(DE-627)ELV025693301 (ELSEVIER)S0038-092X(16)30532-1 |
title_full |
A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions |
author_sort |
Yeung, Ryan Shun-cheung |
journal |
Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? |
journalStr |
Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups? |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science 300 - Social sciences 600 - Technology |
recordtype |
marc |
publishDateSort |
2017 |
contenttype_str_mv |
zzz |
container_start_page |
145 |
author_browse |
Yeung, Ryan Shun-cheung |
container_volume |
141 |
physical |
14 |
class |
530 530 DE-600 333.7 610 VZ 44.13 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Yeung, Ryan Shun-cheung |
doi_str_mv |
10.1016/j.solener.2016.11.017 |
dewey-full |
530 333.7 610 |
title_sort |
a global mppt algorithm for existing pv system mitigating suboptimal operating conditions |
title_auth |
A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions |
abstract |
• A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. |
abstractGer |
• A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. |
abstract_unstemmed |
• A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U |
title_short |
A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions |
url |
https://doi.org/10.1016/j.solener.2016.11.017 |
remote_bool |
true |
author2 |
Chung, Henry Shu-hung Tse, Norman Chung-fai Chuang, Steve Tzu-hsiung |
author2Str |
Chung, Henry Shu-hung Tse, Norman Chung-fai Chuang, Steve Tzu-hsiung |
ppnlink |
ELV007630522 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth |
doi_str |
10.1016/j.solener.2016.11.017 |
up_date |
2024-07-06T18:13:47.377Z |
_version_ |
1803854416317513728 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV025693301</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230623181511.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180603s2017 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.solener.2016.11.017</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBVA2017023000003.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV025693301</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0038-092X(16)30532-1</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2=" "><subfield code="a">530</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="q">DE-600</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">333.7</subfield><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.13</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Yeung, Ryan Shun-cheung</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">A global MPPT algorithm for existing PV system mitigating suboptimal operating conditions</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2017</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">14</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• A two-step algorithm for tracking the global MPP of a PV-string is proposed. • The algorithm has been implemented on a 3kW grid-tie inverter originally using P&O. • The algorithm can enable the inverter to have the capability of tracking the GMPP. • A field test results show that the algorithm can extract 35% more power than the P&O.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Photovoltaic systems</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">MPPT</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Global MPPT</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Solar panels</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chung, Henry Shu-hung</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tse, Norman Chung-fai</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chuang, Steve Tzu-hsiung</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Ji, Yanhu ELSEVIER</subfield><subfield code="t">Association between traffic-related air pollution and anxiety hospitalizations in a coastal Chinese city: are there potentially susceptible groups?</subfield><subfield code="d">2022</subfield><subfield code="d">the official journal of the International Solar Energy Society</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV007630522</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:141</subfield><subfield code="g">year:2017</subfield><subfield code="g">day:1</subfield><subfield code="g">month:01</subfield><subfield code="g">pages:145-158</subfield><subfield code="g">extent:14</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.solener.2016.11.017</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.13</subfield><subfield code="j">Medizinische Ökologie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">141</subfield><subfield code="j">2017</subfield><subfield code="b">1</subfield><subfield code="c">0101</subfield><subfield code="h">145-158</subfield><subfield code="g">14</subfield></datafield><datafield tag="953" ind1=" " ind2=" "><subfield code="2">045F</subfield><subfield code="a">530</subfield></datafield></record></collection>
|
score |
7.4013834 |