Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection
This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electro...
Ausführliche Beschreibung
Autor*in: |
Kasiwattanawut, Haruetai [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2018transfer abstract |
---|
Schlagwörter: |
---|
Umfang: |
6 |
---|
Übergeordnetes Werk: |
Enthalten in: Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system - Wang, Lu ELSEVIER, 2018, a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science, Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:139 ; year:2018 ; pages:181-186 ; extent:6 |
Links: |
---|
DOI / URN: |
10.1016/j.apradiso.2018.05.012 |
---|
Katalog-ID: |
ELV04371255X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV04371255X | ||
003 | DE-627 | ||
005 | 20230626004037.0 | ||
007 | cr uuu---uuuuu | ||
008 | 180726s2018 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.apradiso.2018.05.012 |2 doi | |
028 | 5 | 2 | |a /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica |
035 | |a (DE-627)ELV04371255X | ||
035 | |a (ELSEVIER)S0969-8043(17)31253-8 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 660 |q VZ |
084 | |a 38.51 |2 bkl | ||
084 | |a 57.36 |2 bkl | ||
100 | 1 | |a Kasiwattanawut, Haruetai |e verfasserin |4 aut | |
245 | 1 | 0 | |a Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection |
264 | 1 | |c 2018transfer abstract | |
300 | |a 6 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. | ||
520 | |a This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. | ||
650 | 7 | |a CVD diamond |2 Elsevier | |
650 | 7 | |a Energy range |2 Elsevier | |
650 | 7 | |a Energy resolution, Ni-H LENR System |2 Elsevier | |
650 | 7 | |a Charged particles |2 Elsevier | |
700 | 1 | |a Tchouaso, Modeste Tchakoua |4 oth | |
700 | 1 | |a Prelas, Mark A. |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Wang, Lu ELSEVIER |t Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system |d 2018 |d a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science |g Amsterdam [u.a.] |w (DE-627)ELV001919369 |
773 | 1 | 8 | |g volume:139 |g year:2018 |g pages:181-186 |g extent:6 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.apradiso.2018.05.012 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
912 | |a SSG-OPC-GGO | ||
936 | b | k | |a 38.51 |j Geologie fossiler Brennstoffe |q VZ |
936 | b | k | |a 57.36 |j Erdölgewinnung |j Erdgasgewinnung |q VZ |
951 | |a AR | ||
952 | |d 139 |j 2018 |h 181-186 |g 6 |
author_variant |
h k hk |
---|---|
matchkey_str |
kasiwattanawutharuetaitchouasomodestetch:2018----:ituihnimvdaodesrbltfrhre |
hierarchy_sort_str |
2018transfer abstract |
bklnumber |
38.51 57.36 |
publishDate |
2018 |
allfields |
10.1016/j.apradiso.2018.05.012 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica (DE-627)ELV04371255X (ELSEVIER)S0969-8043(17)31253-8 DE-627 ger DE-627 rakwb eng 660 VZ 38.51 bkl 57.36 bkl Kasiwattanawut, Haruetai verfasserin aut Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection 2018transfer abstract 6 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Elsevier Tchouaso, Modeste Tchakoua oth Prelas, Mark A. oth Enthalten in Elsevier Science Wang, Lu ELSEVIER Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system 2018 a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science Amsterdam [u.a.] (DE-627)ELV001919369 volume:139 year:2018 pages:181-186 extent:6 https://doi.org/10.1016/j.apradiso.2018.05.012 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA SSG-OPC-GGO 38.51 Geologie fossiler Brennstoffe VZ 57.36 Erdölgewinnung Erdgasgewinnung VZ AR 139 2018 181-186 6 |
spelling |
10.1016/j.apradiso.2018.05.012 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica (DE-627)ELV04371255X (ELSEVIER)S0969-8043(17)31253-8 DE-627 ger DE-627 rakwb eng 660 VZ 38.51 bkl 57.36 bkl Kasiwattanawut, Haruetai verfasserin aut Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection 2018transfer abstract 6 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Elsevier Tchouaso, Modeste Tchakoua oth Prelas, Mark A. oth Enthalten in Elsevier Science Wang, Lu ELSEVIER Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system 2018 a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science Amsterdam [u.a.] (DE-627)ELV001919369 volume:139 year:2018 pages:181-186 extent:6 https://doi.org/10.1016/j.apradiso.2018.05.012 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA SSG-OPC-GGO 38.51 Geologie fossiler Brennstoffe VZ 57.36 Erdölgewinnung Erdgasgewinnung VZ AR 139 2018 181-186 6 |
allfields_unstemmed |
10.1016/j.apradiso.2018.05.012 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica (DE-627)ELV04371255X (ELSEVIER)S0969-8043(17)31253-8 DE-627 ger DE-627 rakwb eng 660 VZ 38.51 bkl 57.36 bkl Kasiwattanawut, Haruetai verfasserin aut Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection 2018transfer abstract 6 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Elsevier Tchouaso, Modeste Tchakoua oth Prelas, Mark A. oth Enthalten in Elsevier Science Wang, Lu ELSEVIER Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system 2018 a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science Amsterdam [u.a.] (DE-627)ELV001919369 volume:139 year:2018 pages:181-186 extent:6 https://doi.org/10.1016/j.apradiso.2018.05.012 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA SSG-OPC-GGO 38.51 Geologie fossiler Brennstoffe VZ 57.36 Erdölgewinnung Erdgasgewinnung VZ AR 139 2018 181-186 6 |
allfieldsGer |
10.1016/j.apradiso.2018.05.012 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica (DE-627)ELV04371255X (ELSEVIER)S0969-8043(17)31253-8 DE-627 ger DE-627 rakwb eng 660 VZ 38.51 bkl 57.36 bkl Kasiwattanawut, Haruetai verfasserin aut Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection 2018transfer abstract 6 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Elsevier Tchouaso, Modeste Tchakoua oth Prelas, Mark A. oth Enthalten in Elsevier Science Wang, Lu ELSEVIER Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system 2018 a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science Amsterdam [u.a.] (DE-627)ELV001919369 volume:139 year:2018 pages:181-186 extent:6 https://doi.org/10.1016/j.apradiso.2018.05.012 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA SSG-OPC-GGO 38.51 Geologie fossiler Brennstoffe VZ 57.36 Erdölgewinnung Erdgasgewinnung VZ AR 139 2018 181-186 6 |
allfieldsSound |
10.1016/j.apradiso.2018.05.012 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica (DE-627)ELV04371255X (ELSEVIER)S0969-8043(17)31253-8 DE-627 ger DE-627 rakwb eng 660 VZ 38.51 bkl 57.36 bkl Kasiwattanawut, Haruetai verfasserin aut Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection 2018transfer abstract 6 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Elsevier Tchouaso, Modeste Tchakoua oth Prelas, Mark A. oth Enthalten in Elsevier Science Wang, Lu ELSEVIER Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system 2018 a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science Amsterdam [u.a.] (DE-627)ELV001919369 volume:139 year:2018 pages:181-186 extent:6 https://doi.org/10.1016/j.apradiso.2018.05.012 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA SSG-OPC-GGO 38.51 Geologie fossiler Brennstoffe VZ 57.36 Erdölgewinnung Erdgasgewinnung VZ AR 139 2018 181-186 6 |
language |
English |
source |
Enthalten in Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system Amsterdam [u.a.] volume:139 year:2018 pages:181-186 extent:6 |
sourceStr |
Enthalten in Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system Amsterdam [u.a.] volume:139 year:2018 pages:181-186 extent:6 |
format_phy_str_mv |
Article |
bklname |
Geologie fossiler Brennstoffe Erdölgewinnung Erdgasgewinnung |
institution |
findex.gbv.de |
topic_facet |
CVD diamond Energy range Energy resolution, Ni-H LENR System Charged particles |
dewey-raw |
660 |
isfreeaccess_bool |
false |
container_title |
Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system |
authorswithroles_txt_mv |
Kasiwattanawut, Haruetai @@aut@@ Tchouaso, Modeste Tchakoua @@oth@@ Prelas, Mark A. @@oth@@ |
publishDateDaySort_date |
2018-01-01T00:00:00Z |
hierarchy_top_id |
ELV001919369 |
dewey-sort |
3660 |
id |
ELV04371255X |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV04371255X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230626004037.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180726s2018 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.apradiso.2018.05.012</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">/cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV04371255X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0969-8043(17)31253-8</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">660</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">38.51</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">57.36</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Kasiwattanawut, Haruetai</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">6</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments.</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">CVD diamond</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Energy range</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Energy resolution, Ni-H LENR System</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Charged particles</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tchouaso, Modeste Tchakoua</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Prelas, Mark A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Wang, Lu ELSEVIER</subfield><subfield code="t">Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system</subfield><subfield code="d">2018</subfield><subfield code="d">a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV001919369</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:139</subfield><subfield code="g">year:2018</subfield><subfield code="g">pages:181-186</subfield><subfield code="g">extent:6</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.apradiso.2018.05.012</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OPC-GGO</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">38.51</subfield><subfield code="j">Geologie fossiler Brennstoffe</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">57.36</subfield><subfield code="j">Erdölgewinnung</subfield><subfield code="j">Erdgasgewinnung</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">139</subfield><subfield code="j">2018</subfield><subfield code="h">181-186</subfield><subfield code="g">6</subfield></datafield></record></collection>
|
author |
Kasiwattanawut, Haruetai |
spellingShingle |
Kasiwattanawut, Haruetai ddc 660 bkl 38.51 bkl 57.36 Elsevier CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection |
authorStr |
Kasiwattanawut, Haruetai |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV001919369 |
format |
electronic Article |
dewey-ones |
660 - Chemical engineering |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
660 VZ 38.51 bkl 57.36 bkl Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles Elsevier |
topic |
ddc 660 bkl 38.51 bkl 57.36 Elsevier CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles |
topic_unstemmed |
ddc 660 bkl 38.51 bkl 57.36 Elsevier CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles |
topic_browse |
ddc 660 bkl 38.51 bkl 57.36 Elsevier CVD diamond Elsevier Energy range Elsevier Energy resolution, Ni-H LENR System Elsevier Charged particles |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
m t t mt mtt m a p ma map |
hierarchy_parent_title |
Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system |
hierarchy_parent_id |
ELV001919369 |
dewey-tens |
660 - Chemical engineering |
hierarchy_top_title |
Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV001919369 |
title |
Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection |
ctrlnum |
(DE-627)ELV04371255X (ELSEVIER)S0969-8043(17)31253-8 |
title_full |
Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection |
author_sort |
Kasiwattanawut, Haruetai |
journal |
Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system |
journalStr |
Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2018 |
contenttype_str_mv |
zzz |
container_start_page |
181 |
author_browse |
Kasiwattanawut, Haruetai |
container_volume |
139 |
physical |
6 |
class |
660 VZ 38.51 bkl 57.36 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Kasiwattanawut, Haruetai |
doi_str_mv |
10.1016/j.apradiso.2018.05.012 |
dewey-full |
660 |
title_sort |
ti:pt:au:ni thin-film cvd diamond sensor ability for charged particle detection |
title_auth |
Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection |
abstract |
This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. |
abstractGer |
This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. |
abstract_unstemmed |
This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA SSG-OPC-GGO |
title_short |
Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection |
url |
https://doi.org/10.1016/j.apradiso.2018.05.012 |
remote_bool |
true |
author2 |
Tchouaso, Modeste Tchakoua Prelas, Mark A. |
author2Str |
Tchouaso, Modeste Tchakoua Prelas, Mark A. |
ppnlink |
ELV001919369 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
doi_str |
10.1016/j.apradiso.2018.05.012 |
up_date |
2024-07-06T19:33:01.928Z |
_version_ |
1803859401825583104 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV04371255X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230626004037.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">180726s2018 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.apradiso.2018.05.012</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">/cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001069.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV04371255X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0969-8043(17)31253-8</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">660</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">38.51</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">57.36</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Kasiwattanawut, Haruetai</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Ti:Pt:Au:Ni thin-film CVD diamond sensor ability for charged particle detection</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2018transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">6</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments.</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This work demonstrates the development of diamond sensors with reliable contacts using a new metallization formula, which can operate under high-pressure gas environment. The metallization was created using thin film layers of titanium, platinum, gold and nickel deposited on a single crystal electronic grade CVD diamond chip. The contacts were 2 mm in diameter with thickness of 50/5/20/150 nm of Ti:Pt:Au:Ni. The optimum operating voltage of the sensor was determined from the current-voltage measurements. The sensor was calibrated with 239Pu and 241Am alpha radiation sources at 300 V. The energy resolution of the Ti:Pt:Au:Ni diamond sensor was determined to be 7.6% at 5.2 MeV of 239Pu and 2.2% at 5.48 MeV of 241Am. The high-pressure gas loading environment under which this sensor was used is discussed. Specifically, experimental observations are described using hydrogen loading of nickel as a means of initiating low energy nuclear reactions. No neutrons, electrons, ions or other ionizing radiations were observed in these experiments.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">CVD diamond</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Energy range</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Energy resolution, Ni-H LENR System</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Charged particles</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tchouaso, Modeste Tchakoua</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Prelas, Mark A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Wang, Lu ELSEVIER</subfield><subfield code="t">Time-dependent shape factors for fractured reservoir simulation: Effect of stress sensitivity in matrix system</subfield><subfield code="d">2018</subfield><subfield code="d">a journal of nuclear and radiation techniques and their applications in the physical, chemical, biological, medical, earth, planetary, environmental and engineering science</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV001919369</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:139</subfield><subfield code="g">year:2018</subfield><subfield code="g">pages:181-186</subfield><subfield code="g">extent:6</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.apradiso.2018.05.012</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OPC-GGO</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">38.51</subfield><subfield code="j">Geologie fossiler Brennstoffe</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">57.36</subfield><subfield code="j">Erdölgewinnung</subfield><subfield code="j">Erdgasgewinnung</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">139</subfield><subfield code="j">2018</subfield><subfield code="h">181-186</subfield><subfield code="g">6</subfield></datafield></record></collection>
|
score |
7.3998127 |