Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf>
Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex functio...
Ausführliche Beschreibung
Autor*in: |
Tryner, Jessica [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2019transfer abstract |
---|
Umfang: |
11 |
---|
Übergeordnetes Werk: |
Enthalten in: Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading - Li, Zhaochao ELSEVIER, 2019, Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:250 ; year:2019 ; pages:251-261 ; extent:11 |
Links: |
---|
DOI / URN: |
10.1016/j.envpol.2019.03.121 |
---|
Katalog-ID: |
ELV04684600X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV04684600X | ||
003 | DE-627 | ||
005 | 20230626014433.0 | ||
007 | cr uuu---uuuuu | ||
008 | 191021s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.envpol.2019.03.121 |2 doi | |
028 | 5 | 2 | |a GBV00000000000628.pica |
035 | |a (DE-627)ELV04684600X | ||
035 | |a (ELSEVIER)S0269-7491(19)30295-7 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 690 |q VZ |
084 | |a 50.31 |2 bkl | ||
084 | |a 56.11 |2 bkl | ||
100 | 1 | |a Tryner, Jessica |e verfasserin |4 aut | |
245 | 1 | 0 | |a Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
264 | 1 | |c 2019transfer abstract | |
300 | |a 11 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). | ||
520 | |a Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). | ||
700 | 1 | |a Good, Nicholas |4 oth | |
700 | 1 | |a Wilson, Ander |4 oth | |
700 | 1 | |a Clark, Maggie L. |4 oth | |
700 | 1 | |a Peel, Jennifer L. |4 oth | |
700 | 1 | |a Volckens, John |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Li, Zhaochao ELSEVIER |t Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading |d 2019 |g Amsterdam [u.a.] |w (DE-627)ELV00327988X |
773 | 1 | 8 | |g volume:250 |g year:2019 |g pages:251-261 |g extent:11 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.envpol.2019.03.121 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
936 | b | k | |a 50.31 |j Technische Mechanik |q VZ |
936 | b | k | |a 56.11 |j Baukonstruktion |q VZ |
951 | |a AR | ||
952 | |d 250 |j 2019 |h 251-261 |g 11 |
author_variant |
j t jt |
---|---|
matchkey_str |
trynerjessicagoodnicholaswilsonanderclar:2019----:aitoigaiercorcinatrfrehlmtreieetmtsfesnl |
hierarchy_sort_str |
2019transfer abstract |
bklnumber |
50.31 56.11 |
publishDate |
2019 |
allfields |
10.1016/j.envpol.2019.03.121 doi GBV00000000000628.pica (DE-627)ELV04684600X (ELSEVIER)S0269-7491(19)30295-7 DE-627 ger DE-627 rakwb eng 690 VZ 50.31 bkl 56.11 bkl Tryner, Jessica verfasserin aut Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> 2019transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Good, Nicholas oth Wilson, Ander oth Clark, Maggie L. oth Peel, Jennifer L. oth Volckens, John oth Enthalten in Elsevier Science Li, Zhaochao ELSEVIER Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading 2019 Amsterdam [u.a.] (DE-627)ELV00327988X volume:250 year:2019 pages:251-261 extent:11 https://doi.org/10.1016/j.envpol.2019.03.121 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 50.31 Technische Mechanik VZ 56.11 Baukonstruktion VZ AR 250 2019 251-261 11 |
spelling |
10.1016/j.envpol.2019.03.121 doi GBV00000000000628.pica (DE-627)ELV04684600X (ELSEVIER)S0269-7491(19)30295-7 DE-627 ger DE-627 rakwb eng 690 VZ 50.31 bkl 56.11 bkl Tryner, Jessica verfasserin aut Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> 2019transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Good, Nicholas oth Wilson, Ander oth Clark, Maggie L. oth Peel, Jennifer L. oth Volckens, John oth Enthalten in Elsevier Science Li, Zhaochao ELSEVIER Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading 2019 Amsterdam [u.a.] (DE-627)ELV00327988X volume:250 year:2019 pages:251-261 extent:11 https://doi.org/10.1016/j.envpol.2019.03.121 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 50.31 Technische Mechanik VZ 56.11 Baukonstruktion VZ AR 250 2019 251-261 11 |
allfields_unstemmed |
10.1016/j.envpol.2019.03.121 doi GBV00000000000628.pica (DE-627)ELV04684600X (ELSEVIER)S0269-7491(19)30295-7 DE-627 ger DE-627 rakwb eng 690 VZ 50.31 bkl 56.11 bkl Tryner, Jessica verfasserin aut Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> 2019transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Good, Nicholas oth Wilson, Ander oth Clark, Maggie L. oth Peel, Jennifer L. oth Volckens, John oth Enthalten in Elsevier Science Li, Zhaochao ELSEVIER Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading 2019 Amsterdam [u.a.] (DE-627)ELV00327988X volume:250 year:2019 pages:251-261 extent:11 https://doi.org/10.1016/j.envpol.2019.03.121 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 50.31 Technische Mechanik VZ 56.11 Baukonstruktion VZ AR 250 2019 251-261 11 |
allfieldsGer |
10.1016/j.envpol.2019.03.121 doi GBV00000000000628.pica (DE-627)ELV04684600X (ELSEVIER)S0269-7491(19)30295-7 DE-627 ger DE-627 rakwb eng 690 VZ 50.31 bkl 56.11 bkl Tryner, Jessica verfasserin aut Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> 2019transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Good, Nicholas oth Wilson, Ander oth Clark, Maggie L. oth Peel, Jennifer L. oth Volckens, John oth Enthalten in Elsevier Science Li, Zhaochao ELSEVIER Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading 2019 Amsterdam [u.a.] (DE-627)ELV00327988X volume:250 year:2019 pages:251-261 extent:11 https://doi.org/10.1016/j.envpol.2019.03.121 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 50.31 Technische Mechanik VZ 56.11 Baukonstruktion VZ AR 250 2019 251-261 11 |
allfieldsSound |
10.1016/j.envpol.2019.03.121 doi GBV00000000000628.pica (DE-627)ELV04684600X (ELSEVIER)S0269-7491(19)30295-7 DE-627 ger DE-627 rakwb eng 690 VZ 50.31 bkl 56.11 bkl Tryner, Jessica verfasserin aut Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> 2019transfer abstract 11 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). Good, Nicholas oth Wilson, Ander oth Clark, Maggie L. oth Peel, Jennifer L. oth Volckens, John oth Enthalten in Elsevier Science Li, Zhaochao ELSEVIER Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading 2019 Amsterdam [u.a.] (DE-627)ELV00327988X volume:250 year:2019 pages:251-261 extent:11 https://doi.org/10.1016/j.envpol.2019.03.121 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 50.31 Technische Mechanik VZ 56.11 Baukonstruktion VZ AR 250 2019 251-261 11 |
language |
English |
source |
Enthalten in Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading Amsterdam [u.a.] volume:250 year:2019 pages:251-261 extent:11 |
sourceStr |
Enthalten in Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading Amsterdam [u.a.] volume:250 year:2019 pages:251-261 extent:11 |
format_phy_str_mv |
Article |
bklname |
Technische Mechanik Baukonstruktion |
institution |
findex.gbv.de |
dewey-raw |
690 |
isfreeaccess_bool |
false |
container_title |
Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading |
authorswithroles_txt_mv |
Tryner, Jessica @@aut@@ Good, Nicholas @@oth@@ Wilson, Ander @@oth@@ Clark, Maggie L. @@oth@@ Peel, Jennifer L. @@oth@@ Volckens, John @@oth@@ |
publishDateDaySort_date |
2019-01-01T00:00:00Z |
hierarchy_top_id |
ELV00327988X |
dewey-sort |
3690 |
id |
ELV04684600X |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV04684600X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230626014433.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">191021s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.envpol.2019.03.121</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBV00000000000628.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV04684600X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0269-7491(19)30295-7</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">690</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">50.31</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">56.11</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Tryner, Jessica</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf></subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">11</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study).</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study).</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Good, Nicholas</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wilson, Ander</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Clark, Maggie L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Peel, Jennifer L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Volckens, John</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Li, Zhaochao ELSEVIER</subfield><subfield code="t">Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading</subfield><subfield code="d">2019</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV00327988X</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:250</subfield><subfield code="g">year:2019</subfield><subfield code="g">pages:251-261</subfield><subfield code="g">extent:11</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.envpol.2019.03.121</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">50.31</subfield><subfield code="j">Technische Mechanik</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">56.11</subfield><subfield code="j">Baukonstruktion</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">250</subfield><subfield code="j">2019</subfield><subfield code="h">251-261</subfield><subfield code="g">11</subfield></datafield></record></collection>
|
author |
Tryner, Jessica |
spellingShingle |
Tryner, Jessica ddc 690 bkl 50.31 bkl 56.11 Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
authorStr |
Tryner, Jessica |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV00327988X |
format |
electronic Article |
dewey-ones |
690 - Buildings |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
690 VZ 50.31 bkl 56.11 bkl Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
topic |
ddc 690 bkl 50.31 bkl 56.11 |
topic_unstemmed |
ddc 690 bkl 50.31 bkl 56.11 |
topic_browse |
ddc 690 bkl 50.31 bkl 56.11 |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
n g ng a w aw m l c ml mlc j l p jl jlp j v jv |
hierarchy_parent_title |
Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading |
hierarchy_parent_id |
ELV00327988X |
dewey-tens |
690 - Building & construction |
hierarchy_top_title |
Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV00327988X |
title |
Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
ctrlnum |
(DE-627)ELV04684600X (ELSEVIER)S0269-7491(19)30295-7 |
title_full |
Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
author_sort |
Tryner, Jessica |
journal |
Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading |
journalStr |
Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2019 |
contenttype_str_mv |
zzz |
container_start_page |
251 |
author_browse |
Tryner, Jessica |
container_volume |
250 |
physical |
11 |
class |
690 VZ 50.31 bkl 56.11 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Tryner, Jessica |
doi_str_mv |
10.1016/j.envpol.2019.03.121 |
dewey-full |
690 |
title_sort |
variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to pm<ce:inf loc="post">2.5</ce:inf> |
title_auth |
Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
abstract |
Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). |
abstractGer |
Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). |
abstract_unstemmed |
Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study). |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U |
title_short |
Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf> |
url |
https://doi.org/10.1016/j.envpol.2019.03.121 |
remote_bool |
true |
author2 |
Good, Nicholas Wilson, Ander Clark, Maggie L. Peel, Jennifer L. Volckens, John |
author2Str |
Good, Nicholas Wilson, Ander Clark, Maggie L. Peel, Jennifer L. Volckens, John |
ppnlink |
ELV00327988X |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth |
doi_str |
10.1016/j.envpol.2019.03.121 |
up_date |
2024-07-06T21:17:17.398Z |
_version_ |
1803865961163390976 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV04684600X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230626014433.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">191021s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.envpol.2019.03.121</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBV00000000000628.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV04684600X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0269-7491(19)30295-7</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">690</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">50.31</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">56.11</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Tryner, Jessica</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Variation in gravimetric correction factors for nephelometer-derived estimates of personal exposure to PM<ce:inf loc="post">2.5</ce:inf></subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">11</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study).</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Many portable monitors for quantifying mass concentrations of particulate matter air pollution rely on aerosol light scattering as the measurement method; however, the relationship between scattered light (what is measured) and aerosol mass concentration (the metric of interest) is a complex function of the refractive index, size distribution, and shape of the particles. In this study, we compared 33-h personal PM2.5 concentrations measured simultaneously using nephelometry (personal DataRAM pDR-1200) and gravimetric filter sampling for working adults (44 participants, 249 samples). Nephelometer- and filter-derived 33-h average PM2.5 concentrations were correlated (Spearman's ρ = 0.77); however, the nephelometer-derived concentration was within 20% of the filter-derived concentration for only 13% of samples. The nephelometer/filter ratio, which is used to correct light-scattering measurements to a gravimetric sample, had a median value of 0.52 and varied by over a factor of three (10th percentile = 0.35, 90th percentile = 1.1). When 33-h samples with >50% of 10-s average nephelometer readings below the nephelometer limit of detection were removed from the dataset during sensitivity analyses, the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration increased to 25%. We also evaluated how much the accuracy of nephelometer-derived concentrations improved after applying: (1) a median correction factor derived from a subset of 44 gravimetric samples, (2) participant-specific correction factors derived from one same from each subject, and (3) correction factors predicted using linear models based on other variables recorded during the study. Each approach independently increased the fraction of nephelometer-derived concentrations that were within 20% of the filter-derived concentration to approximately 45%. These results illustrate the challenges with using light scattering (without correction to a concurrent gravimetric sample) to estimate personal exposure to PM2.5 mass among mobile adults exposed to low daily average concentrations (median = 8 μg m−3 in this study).</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Good, Nicholas</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wilson, Ander</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Clark, Maggie L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Peel, Jennifer L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Volckens, John</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Li, Zhaochao ELSEVIER</subfield><subfield code="t">Structural failure performance of the encased functionally graded porous cylinder consolidated by graphene platelet under uniform radial loading</subfield><subfield code="d">2019</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV00327988X</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:250</subfield><subfield code="g">year:2019</subfield><subfield code="g">pages:251-261</subfield><subfield code="g">extent:11</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.envpol.2019.03.121</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">50.31</subfield><subfield code="j">Technische Mechanik</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">56.11</subfield><subfield code="j">Baukonstruktion</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">250</subfield><subfield code="j">2019</subfield><subfield code="h">251-261</subfield><subfield code="g">11</subfield></datafield></record></collection>
|
score |
7.400321 |