Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance
In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determi...
Ausführliche Beschreibung
Autor*in: |
Schmidt, Falko [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2019transfer abstract |
---|
Schlagwörter: |
---|
Umfang: |
8 |
---|
Übergeordnetes Werk: |
Enthalten in: Measuring students' school context exposures: A trajectory-based approach - Halpern-Manners, Andrew ELSEVIER, 2016, affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics, Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:94 ; year:2019 ; day:20 ; month:09 ; pages:211-218 ; extent:8 |
Links: |
---|
DOI / URN: |
10.1016/j.jbiomech.2019.07.043 |
---|
Katalog-ID: |
ELV047843543 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV047843543 | ||
003 | DE-627 | ||
005 | 20230626020617.0 | ||
007 | cr uuu---uuuuu | ||
008 | 191023s2019 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jbiomech.2019.07.043 |2 doi | |
028 | 5 | 2 | |a GBV00000000000741.pica |
035 | |a (DE-627)ELV047843543 | ||
035 | |a (ELSEVIER)S0021-9290(19)30505-6 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 300 |q VZ |
084 | |a 70.00 |2 bkl | ||
084 | |a 71.00 |2 bkl | ||
100 | 1 | |a Schmidt, Falko |e verfasserin |4 aut | |
245 | 1 | 0 | |a Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
264 | 1 | |c 2019transfer abstract | |
300 | |a 8 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. | ||
520 | |a In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. | ||
650 | 7 | |a Finite element method |2 Elsevier | |
650 | 7 | |a Orthodontic tooth movement |2 Elsevier | |
650 | 7 | |a Centre of resistance |2 Elsevier | |
650 | 7 | |a FE model |2 Elsevier | |
650 | 7 | |a Non-linear material |2 Elsevier | |
650 | 7 | |a PDL model |2 Elsevier | |
700 | 1 | |a Lapatki, Bernd Georg |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Halpern-Manners, Andrew ELSEVIER |t Measuring students' school context exposures: A trajectory-based approach |d 2016 |d affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics |g Amsterdam [u.a.] |w (DE-627)ELV00201923X |
773 | 1 | 8 | |g volume:94 |g year:2019 |g day:20 |g month:09 |g pages:211-218 |g extent:8 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.jbiomech.2019.07.043 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
936 | b | k | |a 70.00 |j Sozialwissenschaften allgemein: Allgemeines |q VZ |
936 | b | k | |a 71.00 |j Soziologie: Allgemeines |q VZ |
951 | |a AR | ||
952 | |d 94 |j 2019 |b 20 |c 0920 |h 211-218 |g 8 |
author_variant |
f s fs |
---|---|
matchkey_str |
schmidtfalkolapatkiberndgeorg:2019----:fetfaibeeidnalgmntikesnisolnamtrapoeteoteoa |
hierarchy_sort_str |
2019transfer abstract |
bklnumber |
70.00 71.00 |
publishDate |
2019 |
allfields |
10.1016/j.jbiomech.2019.07.043 doi GBV00000000000741.pica (DE-627)ELV047843543 (ELSEVIER)S0021-9290(19)30505-6 DE-627 ger DE-627 rakwb eng 300 VZ 70.00 bkl 71.00 bkl Schmidt, Falko verfasserin aut Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance 2019transfer abstract 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Elsevier Lapatki, Bernd Georg oth Enthalten in Elsevier Science Halpern-Manners, Andrew ELSEVIER Measuring students' school context exposures: A trajectory-based approach 2016 affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics Amsterdam [u.a.] (DE-627)ELV00201923X volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 https://doi.org/10.1016/j.jbiomech.2019.07.043 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 70.00 Sozialwissenschaften allgemein: Allgemeines VZ 71.00 Soziologie: Allgemeines VZ AR 94 2019 20 0920 211-218 8 |
spelling |
10.1016/j.jbiomech.2019.07.043 doi GBV00000000000741.pica (DE-627)ELV047843543 (ELSEVIER)S0021-9290(19)30505-6 DE-627 ger DE-627 rakwb eng 300 VZ 70.00 bkl 71.00 bkl Schmidt, Falko verfasserin aut Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance 2019transfer abstract 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Elsevier Lapatki, Bernd Georg oth Enthalten in Elsevier Science Halpern-Manners, Andrew ELSEVIER Measuring students' school context exposures: A trajectory-based approach 2016 affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics Amsterdam [u.a.] (DE-627)ELV00201923X volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 https://doi.org/10.1016/j.jbiomech.2019.07.043 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 70.00 Sozialwissenschaften allgemein: Allgemeines VZ 71.00 Soziologie: Allgemeines VZ AR 94 2019 20 0920 211-218 8 |
allfields_unstemmed |
10.1016/j.jbiomech.2019.07.043 doi GBV00000000000741.pica (DE-627)ELV047843543 (ELSEVIER)S0021-9290(19)30505-6 DE-627 ger DE-627 rakwb eng 300 VZ 70.00 bkl 71.00 bkl Schmidt, Falko verfasserin aut Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance 2019transfer abstract 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Elsevier Lapatki, Bernd Georg oth Enthalten in Elsevier Science Halpern-Manners, Andrew ELSEVIER Measuring students' school context exposures: A trajectory-based approach 2016 affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics Amsterdam [u.a.] (DE-627)ELV00201923X volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 https://doi.org/10.1016/j.jbiomech.2019.07.043 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 70.00 Sozialwissenschaften allgemein: Allgemeines VZ 71.00 Soziologie: Allgemeines VZ AR 94 2019 20 0920 211-218 8 |
allfieldsGer |
10.1016/j.jbiomech.2019.07.043 doi GBV00000000000741.pica (DE-627)ELV047843543 (ELSEVIER)S0021-9290(19)30505-6 DE-627 ger DE-627 rakwb eng 300 VZ 70.00 bkl 71.00 bkl Schmidt, Falko verfasserin aut Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance 2019transfer abstract 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Elsevier Lapatki, Bernd Georg oth Enthalten in Elsevier Science Halpern-Manners, Andrew ELSEVIER Measuring students' school context exposures: A trajectory-based approach 2016 affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics Amsterdam [u.a.] (DE-627)ELV00201923X volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 https://doi.org/10.1016/j.jbiomech.2019.07.043 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 70.00 Sozialwissenschaften allgemein: Allgemeines VZ 71.00 Soziologie: Allgemeines VZ AR 94 2019 20 0920 211-218 8 |
allfieldsSound |
10.1016/j.jbiomech.2019.07.043 doi GBV00000000000741.pica (DE-627)ELV047843543 (ELSEVIER)S0021-9290(19)30505-6 DE-627 ger DE-627 rakwb eng 300 VZ 70.00 bkl 71.00 bkl Schmidt, Falko verfasserin aut Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance 2019transfer abstract 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Elsevier Lapatki, Bernd Georg oth Enthalten in Elsevier Science Halpern-Manners, Andrew ELSEVIER Measuring students' school context exposures: A trajectory-based approach 2016 affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics Amsterdam [u.a.] (DE-627)ELV00201923X volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 https://doi.org/10.1016/j.jbiomech.2019.07.043 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U 70.00 Sozialwissenschaften allgemein: Allgemeines VZ 71.00 Soziologie: Allgemeines VZ AR 94 2019 20 0920 211-218 8 |
language |
English |
source |
Enthalten in Measuring students' school context exposures: A trajectory-based approach Amsterdam [u.a.] volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 |
sourceStr |
Enthalten in Measuring students' school context exposures: A trajectory-based approach Amsterdam [u.a.] volume:94 year:2019 day:20 month:09 pages:211-218 extent:8 |
format_phy_str_mv |
Article |
bklname |
Sozialwissenschaften allgemein: Allgemeines Soziologie: Allgemeines |
institution |
findex.gbv.de |
topic_facet |
Finite element method Orthodontic tooth movement Centre of resistance FE model Non-linear material PDL model |
dewey-raw |
300 |
isfreeaccess_bool |
false |
container_title |
Measuring students' school context exposures: A trajectory-based approach |
authorswithroles_txt_mv |
Schmidt, Falko @@aut@@ Lapatki, Bernd Georg @@oth@@ |
publishDateDaySort_date |
2019-01-20T00:00:00Z |
hierarchy_top_id |
ELV00201923X |
dewey-sort |
3300 |
id |
ELV047843543 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV047843543</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230626020617.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">191023s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jbiomech.2019.07.043</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBV00000000000741.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV047843543</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0021-9290(19)30505-6</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">300</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">70.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">71.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Schmidt, Falko</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">8</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry.</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Finite element method</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Orthodontic tooth movement</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Centre of resistance</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">FE model</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Non-linear material</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">PDL model</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lapatki, Bernd Georg</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Halpern-Manners, Andrew ELSEVIER</subfield><subfield code="t">Measuring students' school context exposures: A trajectory-based approach</subfield><subfield code="d">2016</subfield><subfield code="d">affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV00201923X</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:94</subfield><subfield code="g">year:2019</subfield><subfield code="g">day:20</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:211-218</subfield><subfield code="g">extent:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.jbiomech.2019.07.043</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">70.00</subfield><subfield code="j">Sozialwissenschaften allgemein: Allgemeines</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">71.00</subfield><subfield code="j">Soziologie: Allgemeines</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">94</subfield><subfield code="j">2019</subfield><subfield code="b">20</subfield><subfield code="c">0920</subfield><subfield code="h">211-218</subfield><subfield code="g">8</subfield></datafield></record></collection>
|
author |
Schmidt, Falko |
spellingShingle |
Schmidt, Falko ddc 300 bkl 70.00 bkl 71.00 Elsevier Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
authorStr |
Schmidt, Falko |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV00201923X |
format |
electronic Article |
dewey-ones |
300 - Social sciences |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
300 VZ 70.00 bkl 71.00 bkl Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model Elsevier |
topic |
ddc 300 bkl 70.00 bkl 71.00 Elsevier Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model |
topic_unstemmed |
ddc 300 bkl 70.00 bkl 71.00 Elsevier Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model |
topic_browse |
ddc 300 bkl 70.00 bkl 71.00 Elsevier Finite element method Elsevier Orthodontic tooth movement Elsevier Centre of resistance Elsevier FE model Elsevier Non-linear material Elsevier PDL model |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
b g l bg bgl |
hierarchy_parent_title |
Measuring students' school context exposures: A trajectory-based approach |
hierarchy_parent_id |
ELV00201923X |
dewey-tens |
300 - Social sciences, sociology & anthropology |
hierarchy_top_title |
Measuring students' school context exposures: A trajectory-based approach |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV00201923X |
title |
Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
ctrlnum |
(DE-627)ELV047843543 (ELSEVIER)S0021-9290(19)30505-6 |
title_full |
Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
author_sort |
Schmidt, Falko |
journal |
Measuring students' school context exposures: A trajectory-based approach |
journalStr |
Measuring students' school context exposures: A trajectory-based approach |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
300 - Social sciences |
recordtype |
marc |
publishDateSort |
2019 |
contenttype_str_mv |
zzz |
container_start_page |
211 |
author_browse |
Schmidt, Falko |
container_volume |
94 |
physical |
8 |
class |
300 VZ 70.00 bkl 71.00 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Schmidt, Falko |
doi_str_mv |
10.1016/j.jbiomech.2019.07.043 |
dewey-full |
300 |
title_sort |
effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
title_auth |
Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
abstract |
In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. |
abstractGer |
In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. |
abstract_unstemmed |
In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U |
title_short |
Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance |
url |
https://doi.org/10.1016/j.jbiomech.2019.07.043 |
remote_bool |
true |
author2 |
Lapatki, Bernd Georg |
author2Str |
Lapatki, Bernd Georg |
ppnlink |
ELV00201923X |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth |
doi_str |
10.1016/j.jbiomech.2019.07.043 |
up_date |
2024-07-06T17:16:07.634Z |
_version_ |
1803850788514037760 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV047843543</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230626020617.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">191023s2019 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jbiomech.2019.07.043</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">GBV00000000000741.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV047843543</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0021-9290(19)30505-6</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">300</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">70.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">71.00</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Schmidt, Falko</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Effect of variable periodontal ligament thickness and its non-linear material properties on the location of a tooth’s centre of resistance</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019transfer abstract</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">8</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry.</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">In orthodontics, the 3D translational and rotational movement of a tooth is determined by the force–moment system applied and the location of the tooth’s centre of resistance (CR). Because of the practical constraints of in-vivo experiments, the finite element (FE) method is commonly used to determine the CR. The objective of this study was to investigate the geometric model details required for accurate CR determination, and the effect of material non-linearity of the periodontal ligament (PDL). A FE model of a human lower canine derived from a high-resolution µCT scan (voxel size: 50 µm) was investigated by applying four different modelling approaches to the PDL. These comprised linear and non-linear material models, each with uniform and realistic PDL thickness. The CR locations determined for the four model configurations were in the range 37.2–45.3% (alveolar margin: 0%; root apex: 100%). We observed that a non-linear material model introduces load-dependent results that are dominated by the PDL regions under tension. Load variation within the range used in clinical orthodontic practice resulted in CR variations below 0.3%. Furthermore, the individualized realistic PDL geometry shifted the CR towards the alveolar margin by 2.3% and 2.8% on average for the linear and non-linear material models, respectively. We concluded that for conventional clinical therapy and the generation of representative reference data, the least sophisticated modelling approach with linear material behaviour and uniform PDL thickness appears sufficiently accurate. Research applications that require more precise treatment monitoring and planning may, however, benefit from the more accurate results obtained from the non-linear constitutive law and individualized realistic PDL geometry.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Finite element method</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Orthodontic tooth movement</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Centre of resistance</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">FE model</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Non-linear material</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">PDL model</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lapatki, Bernd Georg</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Halpern-Manners, Andrew ELSEVIER</subfield><subfield code="t">Measuring students' school context exposures: A trajectory-based approach</subfield><subfield code="d">2016</subfield><subfield code="d">affiliated with the American Society of Biomechanics, the European Society of Biomechanics, the International Society of Biomechanics, the Japanese Society for Clinical Biomechanics and Related Research and the Australian and New Zealand Society of Biomechanics</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV00201923X</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:94</subfield><subfield code="g">year:2019</subfield><subfield code="g">day:20</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:211-218</subfield><subfield code="g">extent:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.jbiomech.2019.07.043</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">70.00</subfield><subfield code="j">Sozialwissenschaften allgemein: Allgemeines</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">71.00</subfield><subfield code="j">Soziologie: Allgemeines</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">94</subfield><subfield code="j">2019</subfield><subfield code="b">20</subfield><subfield code="c">0920</subfield><subfield code="h">211-218</subfield><subfield code="g">8</subfield></datafield></record></collection>
|
score |
7.3986826 |