The risk of tooth root injuries using cortical screws for intermaxillary fixation and osteosynthesis plates – A retrospective analysis

Intermaxillary fixation (IMF) and osteosynthesis plates (OP) are widely used for the non-surgical and surgical treatment of mandible and condyle fractures. The aim of this retrospective study was to analyze the frequency of tooth root injuries by IMF and OP screws.

Gespeichert in:
Autor*in:

Pabst, Andreas Max [verfasserIn]

Blatt, Sebastian

Epperlein, Pia

Schmidtmann, Irene

Krüger, Maximilian

Schiegnitz, Eik

Goetze, Elisabeth

Ziebart, Thomas

Al-Nawas, Bilal

Format:

E-Artikel

Sprache:

Englisch

Erschienen:

2019

Schlagwörter:

Intermaxillary fixation

Mandible

Screw

Condyle

Osteosynthesis plate

Tooth root injury

Umfang:

12

Übergeordnetes Werk:

Enthalten in: Approaches to label-free flexible DNA biosensors using low-temperature solution-processed InZnO thin-film transistors - Jung, Joohye ELSEVIER, 2014transfer abstract, official publication of the European Association for Cranio-Maxillofacial Surgery, Oxford [u.a.]

Übergeordnetes Werk:

volume:47 ; year:2019 ; number:11 ; pages:1767-1778 ; extent:12