Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water
• A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water.
Autor*in: |
Wu, Yuhao [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2021 |
---|
Übergeordnetes Werk: |
Enthalten in: The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial - Li, Chenglong ELSEVIER, 2019, New York, NY [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:935 ; year:2021 ; day:1 ; month:03 ; pages:0 |
Links: |
---|
DOI / URN: |
10.1016/j.jorganchem.2021.121690 |
---|
Katalog-ID: |
ELV053035992 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV053035992 | ||
003 | DE-627 | ||
005 | 20230624191536.0 | ||
007 | cr uuu---uuuuu | ||
008 | 210910s2021 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.jorganchem.2021.121690 |2 doi | |
028 | 5 | 2 | |a /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica |
035 | |a (DE-627)ELV053035992 | ||
035 | |a (ELSEVIER)S0022-328X(21)00011-5 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 610 |q VZ |
084 | |a 44.85 |2 bkl | ||
084 | |a 44.66 |2 bkl | ||
100 | 1 | |a Wu, Yuhao |e verfasserin |4 aut | |
245 | 1 | 0 | |a Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
264 | 1 | |c 2021 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a • A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. | ||
700 | 1 | |a Du, Kang |4 oth | |
700 | 1 | |a Xu, Ce |4 oth | |
700 | 1 | |a Li, Xianghong |4 oth | |
700 | 1 | |a Tang, Dingguo |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier |a Li, Chenglong ELSEVIER |t The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial |d 2019 |g New York, NY [u.a.] |w (DE-627)ELV002971518 |
773 | 1 | 8 | |g volume:935 |g year:2021 |g day:1 |g month:03 |g pages:0 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.jorganchem.2021.121690 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 44.85 |j Kardiologie |j Angiologie |q VZ |
936 | b | k | |a 44.66 |j Anästhesiologie |q VZ |
951 | |a AR | ||
952 | |d 935 |j 2021 |b 1 |c 0301 |h 0 |
author_variant |
y w yw |
---|---|
matchkey_str |
wuyuhaodukangxucelixianghongtangdingguo:2021----:ihyestvdtcinfguiguhnucml |
hierarchy_sort_str |
2021 |
bklnumber |
44.85 44.66 |
publishDate |
2021 |
allfields |
10.1016/j.jorganchem.2021.121690 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica (DE-627)ELV053035992 (ELSEVIER)S0022-328X(21)00011-5 DE-627 ger DE-627 rakwb eng 610 VZ 44.85 bkl 44.66 bkl Wu, Yuhao verfasserin aut Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water 2021 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. Du, Kang oth Xu, Ce oth Li, Xianghong oth Tang, Dingguo oth Enthalten in Elsevier Li, Chenglong ELSEVIER The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial 2019 New York, NY [u.a.] (DE-627)ELV002971518 volume:935 year:2021 day:1 month:03 pages:0 https://doi.org/10.1016/j.jorganchem.2021.121690 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.85 Kardiologie Angiologie VZ 44.66 Anästhesiologie VZ AR 935 2021 1 0301 0 |
spelling |
10.1016/j.jorganchem.2021.121690 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica (DE-627)ELV053035992 (ELSEVIER)S0022-328X(21)00011-5 DE-627 ger DE-627 rakwb eng 610 VZ 44.85 bkl 44.66 bkl Wu, Yuhao verfasserin aut Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water 2021 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. Du, Kang oth Xu, Ce oth Li, Xianghong oth Tang, Dingguo oth Enthalten in Elsevier Li, Chenglong ELSEVIER The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial 2019 New York, NY [u.a.] (DE-627)ELV002971518 volume:935 year:2021 day:1 month:03 pages:0 https://doi.org/10.1016/j.jorganchem.2021.121690 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.85 Kardiologie Angiologie VZ 44.66 Anästhesiologie VZ AR 935 2021 1 0301 0 |
allfields_unstemmed |
10.1016/j.jorganchem.2021.121690 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica (DE-627)ELV053035992 (ELSEVIER)S0022-328X(21)00011-5 DE-627 ger DE-627 rakwb eng 610 VZ 44.85 bkl 44.66 bkl Wu, Yuhao verfasserin aut Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water 2021 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. Du, Kang oth Xu, Ce oth Li, Xianghong oth Tang, Dingguo oth Enthalten in Elsevier Li, Chenglong ELSEVIER The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial 2019 New York, NY [u.a.] (DE-627)ELV002971518 volume:935 year:2021 day:1 month:03 pages:0 https://doi.org/10.1016/j.jorganchem.2021.121690 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.85 Kardiologie Angiologie VZ 44.66 Anästhesiologie VZ AR 935 2021 1 0301 0 |
allfieldsGer |
10.1016/j.jorganchem.2021.121690 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica (DE-627)ELV053035992 (ELSEVIER)S0022-328X(21)00011-5 DE-627 ger DE-627 rakwb eng 610 VZ 44.85 bkl 44.66 bkl Wu, Yuhao verfasserin aut Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water 2021 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. Du, Kang oth Xu, Ce oth Li, Xianghong oth Tang, Dingguo oth Enthalten in Elsevier Li, Chenglong ELSEVIER The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial 2019 New York, NY [u.a.] (DE-627)ELV002971518 volume:935 year:2021 day:1 month:03 pages:0 https://doi.org/10.1016/j.jorganchem.2021.121690 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.85 Kardiologie Angiologie VZ 44.66 Anästhesiologie VZ AR 935 2021 1 0301 0 |
allfieldsSound |
10.1016/j.jorganchem.2021.121690 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica (DE-627)ELV053035992 (ELSEVIER)S0022-328X(21)00011-5 DE-627 ger DE-627 rakwb eng 610 VZ 44.85 bkl 44.66 bkl Wu, Yuhao verfasserin aut Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water 2021 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. Du, Kang oth Xu, Ce oth Li, Xianghong oth Tang, Dingguo oth Enthalten in Elsevier Li, Chenglong ELSEVIER The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial 2019 New York, NY [u.a.] (DE-627)ELV002971518 volume:935 year:2021 day:1 month:03 pages:0 https://doi.org/10.1016/j.jorganchem.2021.121690 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 44.85 Kardiologie Angiologie VZ 44.66 Anästhesiologie VZ AR 935 2021 1 0301 0 |
language |
English |
source |
Enthalten in The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial New York, NY [u.a.] volume:935 year:2021 day:1 month:03 pages:0 |
sourceStr |
Enthalten in The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial New York, NY [u.a.] volume:935 year:2021 day:1 month:03 pages:0 |
format_phy_str_mv |
Article |
bklname |
Kardiologie Angiologie Anästhesiologie |
institution |
findex.gbv.de |
dewey-raw |
610 |
isfreeaccess_bool |
false |
container_title |
The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial |
authorswithroles_txt_mv |
Wu, Yuhao @@aut@@ Du, Kang @@oth@@ Xu, Ce @@oth@@ Li, Xianghong @@oth@@ Tang, Dingguo @@oth@@ |
publishDateDaySort_date |
2021-01-01T00:00:00Z |
hierarchy_top_id |
ELV002971518 |
dewey-sort |
3610 |
id |
ELV053035992 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV053035992</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230624191536.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">210910s2021 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jorganchem.2021.121690</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">/cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV053035992</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0022-328X(21)00011-5</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.85</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.66</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Wu, Yuhao</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2021</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Du, Kang</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Xu, Ce</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Li, Xianghong</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tang, Dingguo</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier</subfield><subfield code="a">Li, Chenglong ELSEVIER</subfield><subfield code="t">The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial</subfield><subfield code="d">2019</subfield><subfield code="g">New York, NY [u.a.]</subfield><subfield code="w">(DE-627)ELV002971518</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:935</subfield><subfield code="g">year:2021</subfield><subfield code="g">day:1</subfield><subfield code="g">month:03</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.jorganchem.2021.121690</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.85</subfield><subfield code="j">Kardiologie</subfield><subfield code="j">Angiologie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.66</subfield><subfield code="j">Anästhesiologie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">935</subfield><subfield code="j">2021</subfield><subfield code="b">1</subfield><subfield code="c">0301</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
author |
Wu, Yuhao |
spellingShingle |
Wu, Yuhao ddc 610 bkl 44.85 bkl 44.66 Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
authorStr |
Wu, Yuhao |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV002971518 |
format |
electronic Article |
dewey-ones |
610 - Medicine & health |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
610 VZ 44.85 bkl 44.66 bkl Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
topic |
ddc 610 bkl 44.85 bkl 44.66 |
topic_unstemmed |
ddc 610 bkl 44.85 bkl 44.66 |
topic_browse |
ddc 610 bkl 44.85 bkl 44.66 |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
k d kd c x cx x l xl d t dt |
hierarchy_parent_title |
The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial |
hierarchy_parent_id |
ELV002971518 |
dewey-tens |
610 - Medicine & health |
hierarchy_top_title |
The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV002971518 |
title |
Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
ctrlnum |
(DE-627)ELV053035992 (ELSEVIER)S0022-328X(21)00011-5 |
title_full |
Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
author_sort |
Wu, Yuhao |
journal |
The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial |
journalStr |
The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2021 |
contenttype_str_mv |
zzz |
container_start_page |
0 |
author_browse |
Wu, Yuhao |
container_volume |
935 |
class |
610 VZ 44.85 bkl 44.66 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Wu, Yuhao |
doi_str_mv |
10.1016/j.jorganchem.2021.121690 |
dewey-full |
610 |
title_sort |
highly sensitive detection of hg2+ using ruthenium complex-based probe in water |
title_auth |
Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
abstract |
• A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. |
abstractGer |
• A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. |
abstract_unstemmed |
• A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA |
title_short |
Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water |
url |
https://doi.org/10.1016/j.jorganchem.2021.121690 |
remote_bool |
true |
author2 |
Du, Kang Xu, Ce Li, Xianghong Tang, Dingguo |
author2Str |
Du, Kang Xu, Ce Li, Xianghong Tang, Dingguo |
ppnlink |
ELV002971518 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth |
doi_str |
10.1016/j.jorganchem.2021.121690 |
up_date |
2024-07-06T17:49:57.538Z |
_version_ |
1803852917023703040 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV053035992</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230624191536.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">210910s2021 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.jorganchem.2021.121690</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">/cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001292.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV053035992</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0022-328X(21)00011-5</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">610</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.85</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.66</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Wu, Yuhao</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Highly sensitive detection of Hg2+ using ruthenium complex-based probe in water</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2021</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• A new cycloruthenated complex for detecting Hg2+ was synthesized. • It can detect Hg2+ by significant spectral and color changes in water. • Loading the complex onto the NH2-MSNs afforded a new material to detect, enrich and separate Hg2+ in water.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Du, Kang</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Xu, Ce</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Li, Xianghong</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tang, Dingguo</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier</subfield><subfield code="a">Li, Chenglong ELSEVIER</subfield><subfield code="t">The Effect of Simultaneous Renal Replacement Therapy on Extracorporeal Membrane Oxygenation Support for Postcardiotomy Patients with Cardiogenic Shock: A Pilot Randomized Controlled Trial</subfield><subfield code="d">2019</subfield><subfield code="g">New York, NY [u.a.]</subfield><subfield code="w">(DE-627)ELV002971518</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:935</subfield><subfield code="g">year:2021</subfield><subfield code="g">day:1</subfield><subfield code="g">month:03</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.jorganchem.2021.121690</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.85</subfield><subfield code="j">Kardiologie</subfield><subfield code="j">Angiologie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">44.66</subfield><subfield code="j">Anästhesiologie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">935</subfield><subfield code="j">2021</subfield><subfield code="b">1</subfield><subfield code="c">0301</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
score |
7.401025 |