Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system
• The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively.
Autor*in: |
Han, Peng [verfasserIn] |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2022 |
---|
Schlagwörter: |
---|
Übergeordnetes Werk: |
Enthalten in: Synthesis and characterization of AsO[(W,Mo)O - Goudjil, Meriem ELSEVIER, 2023, Amsterdam [u.a.] |
---|---|
Übergeordnetes Werk: |
volume:134 ; year:2022 ; pages:0 |
Links: |
---|
DOI / URN: |
10.1016/j.ijepes.2021.107436 |
---|
Katalog-ID: |
ELV05537963X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | ELV05537963X | ||
003 | DE-627 | ||
005 | 20230624221320.0 | ||
007 | cr uuu---uuuuu | ||
008 | 220105s2022 xx |||||o 00| ||eng c | ||
024 | 7 | |a 10.1016/j.ijepes.2021.107436 |2 doi | |
028 | 5 | 2 | |a /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica |
035 | |a (DE-627)ELV05537963X | ||
035 | |a (ELSEVIER)S0142-0615(21)00675-X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 540 |q VZ |
084 | |a 35.90 |2 bkl | ||
100 | 1 | |a Han, Peng |e verfasserin |4 aut | |
245 | 1 | 0 | |a Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
264 | 1 | |c 2022 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a • The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. | ||
650 | 7 | |a Oxygen |2 Elsevier | |
650 | 7 | |a Corrosion |2 Elsevier | |
650 | 7 | |a Reinforced concrete infrastructure (RCI) |2 Elsevier | |
650 | 7 | |a Quasi-steady state |2 Elsevier | |
650 | 7 | |a Stray current |2 Elsevier | |
700 | 1 | |a Qiao, Guofu |4 oth | |
700 | 1 | |a Guo, Bingbing |4 oth | |
700 | 1 | |a Li, Dongsheng |4 oth | |
700 | 1 | |a Ou, Jinping |4 oth | |
773 | 0 | 8 | |i Enthalten in |n Elsevier Science |a Goudjil, Meriem ELSEVIER |t Synthesis and characterization of AsO[(W,Mo)O |d 2023 |g Amsterdam [u.a.] |w (DE-627)ELV009519483 |
773 | 1 | 8 | |g volume:134 |g year:2022 |g pages:0 |
856 | 4 | 0 | |u https://doi.org/10.1016/j.ijepes.2021.107436 |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a GBV_ELV | ||
912 | |a SYSFLAG_U | ||
912 | |a SSG-OLC-PHA | ||
936 | b | k | |a 35.90 |j Festkörperchemie |q VZ |
951 | |a AR | ||
952 | |d 134 |j 2022 |h 0 |
author_variant |
p h ph |
---|---|
matchkey_str |
hanpengqiaoguofuguobingbinglidongshengou:2022----:netgtooteofeunytacretnuecroinnenocdoceenrsrcueni |
hierarchy_sort_str |
2022 |
bklnumber |
35.90 |
publishDate |
2022 |
allfields |
10.1016/j.ijepes.2021.107436 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica (DE-627)ELV05537963X (ELSEVIER)S0142-0615(21)00675-X DE-627 ger DE-627 rakwb eng 540 VZ 35.90 bkl Han, Peng verfasserin aut Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system 2022 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Elsevier Qiao, Guofu oth Guo, Bingbing oth Li, Dongsheng oth Ou, Jinping oth Enthalten in Elsevier Science Goudjil, Meriem ELSEVIER Synthesis and characterization of AsO[(W,Mo)O 2023 Amsterdam [u.a.] (DE-627)ELV009519483 volume:134 year:2022 pages:0 https://doi.org/10.1016/j.ijepes.2021.107436 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.90 Festkörperchemie VZ AR 134 2022 0 |
spelling |
10.1016/j.ijepes.2021.107436 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica (DE-627)ELV05537963X (ELSEVIER)S0142-0615(21)00675-X DE-627 ger DE-627 rakwb eng 540 VZ 35.90 bkl Han, Peng verfasserin aut Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system 2022 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Elsevier Qiao, Guofu oth Guo, Bingbing oth Li, Dongsheng oth Ou, Jinping oth Enthalten in Elsevier Science Goudjil, Meriem ELSEVIER Synthesis and characterization of AsO[(W,Mo)O 2023 Amsterdam [u.a.] (DE-627)ELV009519483 volume:134 year:2022 pages:0 https://doi.org/10.1016/j.ijepes.2021.107436 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.90 Festkörperchemie VZ AR 134 2022 0 |
allfields_unstemmed |
10.1016/j.ijepes.2021.107436 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica (DE-627)ELV05537963X (ELSEVIER)S0142-0615(21)00675-X DE-627 ger DE-627 rakwb eng 540 VZ 35.90 bkl Han, Peng verfasserin aut Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system 2022 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Elsevier Qiao, Guofu oth Guo, Bingbing oth Li, Dongsheng oth Ou, Jinping oth Enthalten in Elsevier Science Goudjil, Meriem ELSEVIER Synthesis and characterization of AsO[(W,Mo)O 2023 Amsterdam [u.a.] (DE-627)ELV009519483 volume:134 year:2022 pages:0 https://doi.org/10.1016/j.ijepes.2021.107436 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.90 Festkörperchemie VZ AR 134 2022 0 |
allfieldsGer |
10.1016/j.ijepes.2021.107436 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica (DE-627)ELV05537963X (ELSEVIER)S0142-0615(21)00675-X DE-627 ger DE-627 rakwb eng 540 VZ 35.90 bkl Han, Peng verfasserin aut Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system 2022 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Elsevier Qiao, Guofu oth Guo, Bingbing oth Li, Dongsheng oth Ou, Jinping oth Enthalten in Elsevier Science Goudjil, Meriem ELSEVIER Synthesis and characterization of AsO[(W,Mo)O 2023 Amsterdam [u.a.] (DE-627)ELV009519483 volume:134 year:2022 pages:0 https://doi.org/10.1016/j.ijepes.2021.107436 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.90 Festkörperchemie VZ AR 134 2022 0 |
allfieldsSound |
10.1016/j.ijepes.2021.107436 doi /cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica (DE-627)ELV05537963X (ELSEVIER)S0142-0615(21)00675-X DE-627 ger DE-627 rakwb eng 540 VZ 35.90 bkl Han, Peng verfasserin aut Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system 2022 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier • The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Elsevier Qiao, Guofu oth Guo, Bingbing oth Li, Dongsheng oth Ou, Jinping oth Enthalten in Elsevier Science Goudjil, Meriem ELSEVIER Synthesis and characterization of AsO[(W,Mo)O 2023 Amsterdam [u.a.] (DE-627)ELV009519483 volume:134 year:2022 pages:0 https://doi.org/10.1016/j.ijepes.2021.107436 Volltext GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA 35.90 Festkörperchemie VZ AR 134 2022 0 |
language |
English |
source |
Enthalten in Synthesis and characterization of AsO[(W,Mo)O Amsterdam [u.a.] volume:134 year:2022 pages:0 |
sourceStr |
Enthalten in Synthesis and characterization of AsO[(W,Mo)O Amsterdam [u.a.] volume:134 year:2022 pages:0 |
format_phy_str_mv |
Article |
bklname |
Festkörperchemie |
institution |
findex.gbv.de |
topic_facet |
Oxygen Corrosion Reinforced concrete infrastructure (RCI) Quasi-steady state Stray current |
dewey-raw |
540 |
isfreeaccess_bool |
false |
container_title |
Synthesis and characterization of AsO[(W,Mo)O |
authorswithroles_txt_mv |
Han, Peng @@aut@@ Qiao, Guofu @@oth@@ Guo, Bingbing @@oth@@ Li, Dongsheng @@oth@@ Ou, Jinping @@oth@@ |
publishDateDaySort_date |
2022-01-01T00:00:00Z |
hierarchy_top_id |
ELV009519483 |
dewey-sort |
3540 |
id |
ELV05537963X |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV05537963X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230624221320.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">220105s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.ijepes.2021.107436</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">/cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV05537963X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0142-0615(21)00675-X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">35.90</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Han, Peng</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Oxygen</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Corrosion</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Reinforced concrete infrastructure (RCI)</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Quasi-steady state</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Stray current</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Qiao, Guofu</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guo, Bingbing</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Li, Dongsheng</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ou, Jinping</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Goudjil, Meriem ELSEVIER</subfield><subfield code="t">Synthesis and characterization of AsO[(W,Mo)O</subfield><subfield code="d">2023</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV009519483</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:134</subfield><subfield code="g">year:2022</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.ijepes.2021.107436</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">35.90</subfield><subfield code="j">Festkörperchemie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">134</subfield><subfield code="j">2022</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
author |
Han, Peng |
spellingShingle |
Han, Peng ddc 540 bkl 35.90 Elsevier Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
authorStr |
Han, Peng |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)ELV009519483 |
format |
electronic Article |
dewey-ones |
540 - Chemistry & allied sciences |
delete_txt_mv |
keep |
author_role |
aut |
collection |
elsevier |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
540 VZ 35.90 bkl Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current Elsevier |
topic |
ddc 540 bkl 35.90 Elsevier Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current |
topic_unstemmed |
ddc 540 bkl 35.90 Elsevier Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current |
topic_browse |
ddc 540 bkl 35.90 Elsevier Oxygen Elsevier Corrosion Elsevier Reinforced concrete infrastructure (RCI) Elsevier Quasi-steady state Elsevier Stray current |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
g q gq b g bg d l dl j o jo |
hierarchy_parent_title |
Synthesis and characterization of AsO[(W,Mo)O |
hierarchy_parent_id |
ELV009519483 |
dewey-tens |
540 - Chemistry |
hierarchy_top_title |
Synthesis and characterization of AsO[(W,Mo)O |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)ELV009519483 |
title |
Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
ctrlnum |
(DE-627)ELV05537963X (ELSEVIER)S0142-0615(21)00675-X |
title_full |
Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
author_sort |
Han, Peng |
journal |
Synthesis and characterization of AsO[(W,Mo)O |
journalStr |
Synthesis and characterization of AsO[(W,Mo)O |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science |
recordtype |
marc |
publishDateSort |
2022 |
contenttype_str_mv |
zzz |
container_start_page |
0 |
author_browse |
Han, Peng |
container_volume |
134 |
class |
540 VZ 35.90 bkl |
format_se |
Elektronische Aufsätze |
author-letter |
Han, Peng |
doi_str_mv |
10.1016/j.ijepes.2021.107436 |
dewey-full |
540 |
title_sort |
investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
title_auth |
Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
abstract |
• The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. |
abstractGer |
• The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. |
abstract_unstemmed |
• The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively. |
collection_details |
GBV_USEFLAG_U GBV_ELV SYSFLAG_U SSG-OLC-PHA |
title_short |
Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system |
url |
https://doi.org/10.1016/j.ijepes.2021.107436 |
remote_bool |
true |
author2 |
Qiao, Guofu Guo, Bingbing Li, Dongsheng Ou, Jinping |
author2Str |
Qiao, Guofu Guo, Bingbing Li, Dongsheng Ou, Jinping |
ppnlink |
ELV009519483 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth |
doi_str |
10.1016/j.ijepes.2021.107436 |
up_date |
2024-07-06T17:23:12.360Z |
_version_ |
1803851233871527936 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">ELV05537963X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230624221320.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">220105s2022 xx |||||o 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1016/j.ijepes.2021.107436</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">/cbs_pica/cbs_olc/import_discovery/elsevier/einzuspielen/GBV00000000001535.pica</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)ELV05537963X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(ELSEVIER)S0142-0615(21)00675-X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">540</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">35.90</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Han, Peng</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2022</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">• The consumption-transport model of oxygen subjected to stray current is proposed. • The electrode kinetics and dissolved oxygen concentration are coupled. • The corrosion of the different pore saturated mortar are compared quantitatively.</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Oxygen</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Corrosion</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Reinforced concrete infrastructure (RCI)</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Quasi-steady state</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="650" ind1=" " ind2="7"><subfield code="a">Stray current</subfield><subfield code="2">Elsevier</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Qiao, Guofu</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Guo, Bingbing</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Li, Dongsheng</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ou, Jinping</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="n">Elsevier Science</subfield><subfield code="a">Goudjil, Meriem ELSEVIER</subfield><subfield code="t">Synthesis and characterization of AsO[(W,Mo)O</subfield><subfield code="d">2023</subfield><subfield code="g">Amsterdam [u.a.]</subfield><subfield code="w">(DE-627)ELV009519483</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:134</subfield><subfield code="g">year:2022</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1016/j.ijepes.2021.107436</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ELV</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHA</subfield></datafield><datafield tag="936" ind1="b" ind2="k"><subfield code="a">35.90</subfield><subfield code="j">Festkörperchemie</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">134</subfield><subfield code="j">2022</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
score |
7.4015865 |