The impact of organ-at-risk contour variations on automatically generated treatment plans for NSCLC

• Quantification of the effect of contouring inaccuracies on plan optimization. • Dose differences from (auto-)contouring are similar to intra-observer variability. • Heart requires checking and adjusting when overlapping with PTV. • OARs with max dose constraints require checking and adjustment whe...
Ausführliche Beschreibung

Gespeichert in:
Autor*in:

Vaassen, Femke [verfasserIn]

Hazelaar, Colien

Canters, Richard

Peeters, Stephanie

Petit, Steven

van Elmpt, Wouter

Format:

E-Artikel

Sprache:

Englisch

Erschienen:

2021

Schlagwörter:

Dosimetric differences

Automatic planning

Radiotherapy

Delineation inaccuracies

Intra-observer variability

Automatic contouring

Umfang:

7

Übergeordnetes Werk:

Enthalten in: Identification of proteins related with pemetrexed resistance by iTRAQ and PRM-based comparative proteomic analysis and exploration of IGF2BP2 and FOLR1 functions in non-small cell lung cancer cells - Han, Xiaobing ELSEVIER, 2021, journal of the European Society for Therapeutic Radiology and Oncology, Amsterdam [u.a.]

Übergeordnetes Werk:

volume:163 ; year:2021 ; pages:136-142 ; extent:7