A continuous neutron level gauge
A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1983 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: The International Journal Of Applied Radiation And Isotopes - Amsterdam : Elsevier, 34(1983), 9, Seite 1377-1382 |
Übergeordnetes Werk: |
volume:34 ; year:1983 ; number:9 ; pages:1377-1382 |
Links: |
---|
Katalog-ID: |
NLEJ179387715 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ179387715 | ||
003 | DE-627 | ||
005 | 20210706100759.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1983 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ179387715 | ||
035 | |a (DE-599)GBVNLZ179387715 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 2 | |a A continuous neutron level gauge |
264 | 1 | |c 1983 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Mathew, P.J. |4 oth | |
700 | 1 | |a Ceravolo, C. |4 oth | |
700 | 1 | |a Huppert, P. |4 oth | |
700 | 1 | |a Miles, J.G. |4 oth | |
773 | 0 | 8 | |i in |t The International Journal Of Applied Radiation And Isotopes |d Amsterdam : Elsevier |g 34(1983), 9, Seite 1377-1382 |w (DE-627)NLEJ177315059 |w (DE-600)2197707-0 |x 0020-708X |7 nnns |
773 | 1 | 8 | |g volume:34 |g year:1983 |g number:9 |g pages:1377-1382 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 34 |j 1983 |e 9 |h 1377-1382 |
matchkey_str |
article:0020708X:1983----::cniuunurne |
---|---|
hierarchy_sort_str |
1983 |
publishDate |
1983 |
allfields |
(DE-627)NLEJ179387715 (DE-599)GBVNLZ179387715 DE-627 ger DE-627 rakwb eng A continuous neutron level gauge 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Mathew, P.J. oth Ceravolo, C. oth Huppert, P. oth Miles, J.G. oth in The International Journal Of Applied Radiation And Isotopes Amsterdam : Elsevier 34(1983), 9, Seite 1377-1382 (DE-627)NLEJ177315059 (DE-600)2197707-0 0020-708X nnns volume:34 year:1983 number:9 pages:1377-1382 http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 34 1983 9 1377-1382 |
spelling |
(DE-627)NLEJ179387715 (DE-599)GBVNLZ179387715 DE-627 ger DE-627 rakwb eng A continuous neutron level gauge 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Mathew, P.J. oth Ceravolo, C. oth Huppert, P. oth Miles, J.G. oth in The International Journal Of Applied Radiation And Isotopes Amsterdam : Elsevier 34(1983), 9, Seite 1377-1382 (DE-627)NLEJ177315059 (DE-600)2197707-0 0020-708X nnns volume:34 year:1983 number:9 pages:1377-1382 http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 34 1983 9 1377-1382 |
allfields_unstemmed |
(DE-627)NLEJ179387715 (DE-599)GBVNLZ179387715 DE-627 ger DE-627 rakwb eng A continuous neutron level gauge 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Mathew, P.J. oth Ceravolo, C. oth Huppert, P. oth Miles, J.G. oth in The International Journal Of Applied Radiation And Isotopes Amsterdam : Elsevier 34(1983), 9, Seite 1377-1382 (DE-627)NLEJ177315059 (DE-600)2197707-0 0020-708X nnns volume:34 year:1983 number:9 pages:1377-1382 http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 34 1983 9 1377-1382 |
allfieldsGer |
(DE-627)NLEJ179387715 (DE-599)GBVNLZ179387715 DE-627 ger DE-627 rakwb eng A continuous neutron level gauge 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Mathew, P.J. oth Ceravolo, C. oth Huppert, P. oth Miles, J.G. oth in The International Journal Of Applied Radiation And Isotopes Amsterdam : Elsevier 34(1983), 9, Seite 1377-1382 (DE-627)NLEJ177315059 (DE-600)2197707-0 0020-708X nnns volume:34 year:1983 number:9 pages:1377-1382 http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 34 1983 9 1377-1382 |
allfieldsSound |
(DE-627)NLEJ179387715 (DE-599)GBVNLZ179387715 DE-627 ger DE-627 rakwb eng A continuous neutron level gauge 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Mathew, P.J. oth Ceravolo, C. oth Huppert, P. oth Miles, J.G. oth in The International Journal Of Applied Radiation And Isotopes Amsterdam : Elsevier 34(1983), 9, Seite 1377-1382 (DE-627)NLEJ177315059 (DE-600)2197707-0 0020-708X nnns volume:34 year:1983 number:9 pages:1377-1382 http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 34 1983 9 1377-1382 |
language |
English |
source |
in The International Journal Of Applied Radiation And Isotopes 34(1983), 9, Seite 1377-1382 volume:34 year:1983 number:9 pages:1377-1382 |
sourceStr |
in The International Journal Of Applied Radiation And Isotopes 34(1983), 9, Seite 1377-1382 volume:34 year:1983 number:9 pages:1377-1382 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
The International Journal Of Applied Radiation And Isotopes |
authorswithroles_txt_mv |
Mathew, P.J. @@oth@@ Ceravolo, C. @@oth@@ Huppert, P. @@oth@@ Miles, J.G. @@oth@@ |
publishDateDaySort_date |
1983-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ177315059 |
id |
NLEJ179387715 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ179387715</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706100759.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1983 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ179387715</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ179387715</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A continuous neutron level gauge</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1983</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mathew, P.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ceravolo, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Huppert, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Miles, J.G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">The International Journal Of Applied Radiation And Isotopes</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">34(1983), 9, Seite 1377-1382</subfield><subfield code="w">(DE-627)NLEJ177315059</subfield><subfield code="w">(DE-600)2197707-0</subfield><subfield code="x">0020-708X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:34</subfield><subfield code="g">year:1983</subfield><subfield code="g">number:9</subfield><subfield code="g">pages:1377-1382</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">34</subfield><subfield code="j">1983</subfield><subfield code="e">9</subfield><subfield code="h">1377-1382</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ177315059 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0020-708X |
topic_title |
A continuous neutron level gauge |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
p m pm c c cc p h ph j m jm |
hierarchy_parent_title |
The International Journal Of Applied Radiation And Isotopes |
hierarchy_parent_id |
NLEJ177315059 |
hierarchy_top_title |
The International Journal Of Applied Radiation And Isotopes |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ177315059 (DE-600)2197707-0 |
title |
A continuous neutron level gauge |
spellingShingle |
A continuous neutron level gauge |
ctrlnum |
(DE-627)NLEJ179387715 (DE-599)GBVNLZ179387715 |
title_full |
A continuous neutron level gauge |
journal |
The International Journal Of Applied Radiation And Isotopes |
journalStr |
The International Journal Of Applied Radiation And Isotopes |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1983 |
contenttype_str_mv |
zzz |
container_start_page |
1377 |
container_volume |
34 |
format_se |
Elektronische Aufsätze |
title_sort |
continuous neutron level gauge |
title_auth |
A continuous neutron level gauge |
abstract |
A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. |
abstractGer |
A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. |
abstract_unstemmed |
A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
9 |
title_short |
A continuous neutron level gauge |
url |
http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5 |
remote_bool |
true |
author2 |
Mathew, P.J. Ceravolo, C. Huppert, P. Miles, J.G. |
author2Str |
Mathew, P.J. Ceravolo, C. Huppert, P. Miles, J.G. |
ppnlink |
NLEJ177315059 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth |
up_date |
2024-07-06T00:42:52.649Z |
_version_ |
1803788298644094976 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ179387715</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706100759.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1983 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ179387715</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ179387715</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A continuous neutron level gauge</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1983</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A continuous neutron level gauge has been developed for the level measurement of hydrogenous as well as non-hydrogenous materials in containers of any size. Laboratory and plant trials with the prototype showed the gauge to be capable of indicating solid and liquid levels to within +/- 5cm (lσ) and-with minor modifications-to within +/-0.2 cm for liquids. The gauge has the potential for the simultaneous measurement of level and moisture content of materials. Laboratory study has shown that the instrument can determine the moisture content of iron ore samples to within 0.5% moisture. The gauge requires only a weak neutron source associated with a negligible radiation hazard. The gauge is being made available commercially.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mathew, P.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ceravolo, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Huppert, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Miles, J.G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">The International Journal Of Applied Radiation And Isotopes</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">34(1983), 9, Seite 1377-1382</subfield><subfield code="w">(DE-627)NLEJ177315059</subfield><subfield code="w">(DE-600)2197707-0</subfield><subfield code="x">0020-708X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:34</subfield><subfield code="g">year:1983</subfield><subfield code="g">number:9</subfield><subfield code="g">pages:1377-1382</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0020-708X(83)90031-5</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">34</subfield><subfield code="j">1983</subfield><subfield code="e">9</subfield><subfield code="h">1377-1382</subfield></datafield></record></collection>
|
score |
7.398406 |