Thin cation-exchange foils
Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1962 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods - Amsterdam : Elsevier, 15(1962), 3, Seite 233-236 |
Übergeordnetes Werk: |
volume:15 ; year:1962 ; number:3 ; pages:233-236 |
Links: |
---|
Katalog-ID: |
NLEJ180454412 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ180454412 | ||
003 | DE-627 | ||
005 | 20210706125850.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1962 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ180454412 | ||
035 | |a (DE-599)GBVNLZ180454412 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Thin cation-exchange foils |
264 | 1 | |c 1962 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Bjornholm, S. |4 oth | |
700 | 1 | |a Michael Lederer, C. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods |d Amsterdam : Elsevier |g 15(1962), 3, Seite 233-236 |w (DE-627)NLEJ177071524 |w (DE-600)2205646-4 |x 0029-554X |7 nnns |
773 | 1 | 8 | |g volume:15 |g year:1962 |g number:3 |g pages:233-236 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 15 |j 1962 |e 3 |h 233-236 |
matchkey_str |
article:0029554X:1962----::hnainxh |
---|---|
hierarchy_sort_str |
1962 |
publishDate |
1962 |
allfields |
(DE-627)NLEJ180454412 (DE-599)GBVNLZ180454412 DE-627 ger DE-627 rakwb eng Thin cation-exchange foils 1962 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bjornholm, S. oth Michael Lederer, C. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 15(1962), 3, Seite 233-236 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:15 year:1962 number:3 pages:233-236 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 15 1962 3 233-236 |
spelling |
(DE-627)NLEJ180454412 (DE-599)GBVNLZ180454412 DE-627 ger DE-627 rakwb eng Thin cation-exchange foils 1962 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bjornholm, S. oth Michael Lederer, C. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 15(1962), 3, Seite 233-236 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:15 year:1962 number:3 pages:233-236 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 15 1962 3 233-236 |
allfields_unstemmed |
(DE-627)NLEJ180454412 (DE-599)GBVNLZ180454412 DE-627 ger DE-627 rakwb eng Thin cation-exchange foils 1962 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bjornholm, S. oth Michael Lederer, C. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 15(1962), 3, Seite 233-236 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:15 year:1962 number:3 pages:233-236 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 15 1962 3 233-236 |
allfieldsGer |
(DE-627)NLEJ180454412 (DE-599)GBVNLZ180454412 DE-627 ger DE-627 rakwb eng Thin cation-exchange foils 1962 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bjornholm, S. oth Michael Lederer, C. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 15(1962), 3, Seite 233-236 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:15 year:1962 number:3 pages:233-236 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 15 1962 3 233-236 |
allfieldsSound |
(DE-627)NLEJ180454412 (DE-599)GBVNLZ180454412 DE-627 ger DE-627 rakwb eng Thin cation-exchange foils 1962 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bjornholm, S. oth Michael Lederer, C. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 15(1962), 3, Seite 233-236 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:15 year:1962 number:3 pages:233-236 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 15 1962 3 233-236 |
language |
English |
source |
in Nuclear Instruments and Methods 15(1962), 3, Seite 233-236 volume:15 year:1962 number:3 pages:233-236 |
sourceStr |
in Nuclear Instruments and Methods 15(1962), 3, Seite 233-236 volume:15 year:1962 number:3 pages:233-236 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods |
authorswithroles_txt_mv |
Bjornholm, S. @@oth@@ Michael Lederer, C. @@oth@@ |
publishDateDaySort_date |
1962-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ177071524 |
id |
NLEJ180454412 |
language_de |
englisch |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180454412</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706125850.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1962 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180454412</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180454412</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Thin cation-exchange foils</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1962</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bjornholm, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Michael Lederer, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">15(1962), 3, Seite 233-236</subfield><subfield code="w">(DE-627)NLEJ177071524</subfield><subfield code="w">(DE-600)2205646-4</subfield><subfield code="x">0029-554X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:15</subfield><subfield code="g">year:1962</subfield><subfield code="g">number:3</subfield><subfield code="g">pages:233-236</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">15</subfield><subfield code="j">1962</subfield><subfield code="e">3</subfield><subfield code="h">233-236</subfield></datafield></record></collection>
|
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180454412</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706125850.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1962 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180454412</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180454412</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Thin cation-exchange foils</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1962</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bjornholm, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Michael Lederer, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">15(1962), 3, Seite 233-236</subfield><subfield code="w">(DE-627)NLEJ177071524</subfield><subfield code="w">(DE-600)2205646-4</subfield><subfield code="x">0029-554X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:15</subfield><subfield code="g">year:1962</subfield><subfield code="g">number:3</subfield><subfield code="g">pages:233-236</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">15</subfield><subfield code="j">1962</subfield><subfield code="e">3</subfield><subfield code="h">233-236</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ177071524 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0029-554X |
topic_title |
Thin cation-exchange foils |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
s b sb l c m lc lcm |
hierarchy_parent_title |
Nuclear Instruments and Methods |
hierarchy_parent_id |
NLEJ177071524 |
hierarchy_top_title |
Nuclear Instruments and Methods |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ177071524 (DE-600)2205646-4 |
title |
Thin cation-exchange foils |
spellingShingle |
Thin cation-exchange foils |
ctrlnum |
(DE-627)NLEJ180454412 (DE-599)GBVNLZ180454412 |
title_full |
Thin cation-exchange foils |
journal |
Nuclear Instruments and Methods |
journalStr |
Nuclear Instruments and Methods |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1962 |
contenttype_str_mv |
zzz |
container_start_page |
233 |
container_volume |
15 |
format_se |
Elektronische Aufsätze |
title_sort |
thin cation-exchange foils |
title_auth |
Thin cation-exchange foils |
abstract |
Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. |
abstractGer |
Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. |
abstract_unstemmed |
Treatment of commercial polystyrene sheets with fuming sulfuric acid produces a thin layer of cation exchanger. The ion exchange capacity of the layer is measured by an isotope dilution procedure which utilizes Th^2^2^8 and Th^2^3^2. At the same time the thickness is found from the yield of Ra^2^2^4 which escapes from the foils as α-decay recoils.A specific capacity of 5.6 milliequivalents per gram can readily be obtained, and the thickness can be varied from a few to several hundred micrograms/cm^2. The foils have been used for simple and fast preparation of α sources. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
3 |
title_short |
Thin cation-exchange foils |
url |
http://linkinghub.elsevier.com/retrieve/pii/0029-554X(62)90082-4 |
remote_bool |
true |
author2 |
Bjornholm, S. Michael Lederer, C. |
author2Str |
Bjornholm, S. Michael Lederer, C. |
ppnlink |
NLEJ177071524 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
up_date |
2024-07-06T03:28:09.335Z |
_version_ |
1803798697040936961 |
score |
7.4005327 |