Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions
An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire propo...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1978 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods - Amsterdam : Elsevier, 155(1978), 1-2, Seite 61-74 |
Übergeordnetes Werk: |
volume:155 ; year:1978 ; number:1-2 ; pages:61-74 |
Links: |
---|
Katalog-ID: |
NLEJ18050519X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ18050519X | ||
003 | DE-627 | ||
005 | 20210706130630.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1978 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ18050519X | ||
035 | |a (DE-599)GBVNLZ18050519X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
264 | 1 | |c 1978 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Badelek, B. |4 oth | |
700 | 1 | |a Berthot, J. |4 oth | |
700 | 1 | |a Burq, J.P. |4 oth | |
700 | 1 | |a Chemarin, M. |4 oth | |
700 | 1 | |a Chevallier, M. |4 oth | |
700 | 1 | |a Cotte, P. |4 oth | |
700 | 1 | |a Dore, C. |4 oth | |
700 | 1 | |a Douhet, G. |4 oth | |
700 | 1 | |a Dahlgren, S. |4 oth | |
700 | 1 | |a Ekelof, T. |4 oth | |
700 | 1 | |a Grafstrom, P. |4 oth | |
700 | 1 | |a Gajewski, W. |4 oth | |
700 | 1 | |a Hagberg, E. |4 oth | |
700 | 1 | |a Hallgren, A. |4 oth | |
700 | 1 | |a Ille, B. |4 oth | |
700 | 1 | |a Jonsson, S. |4 oth | |
700 | 1 | |a Kullander, S. |4 oth | |
700 | 1 | |a Lambert, M. |4 oth | |
700 | 1 | |a Martin, J.P. |4 oth | |
700 | 1 | |a Maury, S. |4 oth | |
700 | 1 | |a Meritet, L. |4 oth | |
700 | 1 | |a Nassalski, J. |4 oth | |
700 | 1 | |a Querrou, M. |4 oth | |
700 | 1 | |a Vazeille, F. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods |d Amsterdam : Elsevier |g 155(1978), 1-2, Seite 61-74 |w (DE-627)NLEJ177071524 |w (DE-600)2205646-4 |x 0029-554X |7 nnns |
773 | 1 | 8 | |g volume:155 |g year:1978 |g number:1-2 |g pages:61-74 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 155 |j 1978 |e 1-2 |h 61-74 |
matchkey_str |
article:0029554X:1978----::pcrmtrfresrmnsfeoladcteeprilsrmgv |
---|---|
hierarchy_sort_str |
1978 |
publishDate |
1978 |
allfields |
(DE-627)NLEJ18050519X (DE-599)GBVNLZ18050519X DE-627 ger DE-627 rakwb eng Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions 1978 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Badelek, B. oth Berthot, J. oth Burq, J.P. oth Chemarin, M. oth Chevallier, M. oth Cotte, P. oth Dore, C. oth Douhet, G. oth Dahlgren, S. oth Ekelof, T. oth Grafstrom, P. oth Gajewski, W. oth Hagberg, E. oth Hallgren, A. oth Ille, B. oth Jonsson, S. oth Kullander, S. oth Lambert, M. oth Martin, J.P. oth Maury, S. oth Meritet, L. oth Nassalski, J. oth Querrou, M. oth Vazeille, F. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 155(1978), 1-2, Seite 61-74 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:155 year:1978 number:1-2 pages:61-74 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 155 1978 1-2 61-74 |
spelling |
(DE-627)NLEJ18050519X (DE-599)GBVNLZ18050519X DE-627 ger DE-627 rakwb eng Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions 1978 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Badelek, B. oth Berthot, J. oth Burq, J.P. oth Chemarin, M. oth Chevallier, M. oth Cotte, P. oth Dore, C. oth Douhet, G. oth Dahlgren, S. oth Ekelof, T. oth Grafstrom, P. oth Gajewski, W. oth Hagberg, E. oth Hallgren, A. oth Ille, B. oth Jonsson, S. oth Kullander, S. oth Lambert, M. oth Martin, J.P. oth Maury, S. oth Meritet, L. oth Nassalski, J. oth Querrou, M. oth Vazeille, F. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 155(1978), 1-2, Seite 61-74 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:155 year:1978 number:1-2 pages:61-74 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 155 1978 1-2 61-74 |
allfields_unstemmed |
(DE-627)NLEJ18050519X (DE-599)GBVNLZ18050519X DE-627 ger DE-627 rakwb eng Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions 1978 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Badelek, B. oth Berthot, J. oth Burq, J.P. oth Chemarin, M. oth Chevallier, M. oth Cotte, P. oth Dore, C. oth Douhet, G. oth Dahlgren, S. oth Ekelof, T. oth Grafstrom, P. oth Gajewski, W. oth Hagberg, E. oth Hallgren, A. oth Ille, B. oth Jonsson, S. oth Kullander, S. oth Lambert, M. oth Martin, J.P. oth Maury, S. oth Meritet, L. oth Nassalski, J. oth Querrou, M. oth Vazeille, F. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 155(1978), 1-2, Seite 61-74 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:155 year:1978 number:1-2 pages:61-74 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 155 1978 1-2 61-74 |
allfieldsGer |
(DE-627)NLEJ18050519X (DE-599)GBVNLZ18050519X DE-627 ger DE-627 rakwb eng Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions 1978 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Badelek, B. oth Berthot, J. oth Burq, J.P. oth Chemarin, M. oth Chevallier, M. oth Cotte, P. oth Dore, C. oth Douhet, G. oth Dahlgren, S. oth Ekelof, T. oth Grafstrom, P. oth Gajewski, W. oth Hagberg, E. oth Hallgren, A. oth Ille, B. oth Jonsson, S. oth Kullander, S. oth Lambert, M. oth Martin, J.P. oth Maury, S. oth Meritet, L. oth Nassalski, J. oth Querrou, M. oth Vazeille, F. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 155(1978), 1-2, Seite 61-74 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:155 year:1978 number:1-2 pages:61-74 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 155 1978 1-2 61-74 |
allfieldsSound |
(DE-627)NLEJ18050519X (DE-599)GBVNLZ18050519X DE-627 ger DE-627 rakwb eng Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions 1978 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Badelek, B. oth Berthot, J. oth Burq, J.P. oth Chemarin, M. oth Chevallier, M. oth Cotte, P. oth Dore, C. oth Douhet, G. oth Dahlgren, S. oth Ekelof, T. oth Grafstrom, P. oth Gajewski, W. oth Hagberg, E. oth Hallgren, A. oth Ille, B. oth Jonsson, S. oth Kullander, S. oth Lambert, M. oth Martin, J.P. oth Maury, S. oth Meritet, L. oth Nassalski, J. oth Querrou, M. oth Vazeille, F. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 155(1978), 1-2, Seite 61-74 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:155 year:1978 number:1-2 pages:61-74 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 155 1978 1-2 61-74 |
language |
English |
source |
in Nuclear Instruments and Methods 155(1978), 1-2, Seite 61-74 volume:155 year:1978 number:1-2 pages:61-74 |
sourceStr |
in Nuclear Instruments and Methods 155(1978), 1-2, Seite 61-74 volume:155 year:1978 number:1-2 pages:61-74 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods |
authorswithroles_txt_mv |
Badelek, B. @@oth@@ Berthot, J. @@oth@@ Burq, J.P. @@oth@@ Chemarin, M. @@oth@@ Chevallier, M. @@oth@@ Cotte, P. @@oth@@ Dore, C. @@oth@@ Douhet, G. @@oth@@ Dahlgren, S. @@oth@@ Ekelof, T. @@oth@@ Grafstrom, P. @@oth@@ Gajewski, W. @@oth@@ Hagberg, E. @@oth@@ Hallgren, A. @@oth@@ Ille, B. @@oth@@ Jonsson, S. @@oth@@ Kullander, S. @@oth@@ Lambert, M. @@oth@@ Martin, J.P. @@oth@@ Maury, S. @@oth@@ Meritet, L. @@oth@@ Nassalski, J. @@oth@@ Querrou, M. @@oth@@ Vazeille, F. @@oth@@ |
publishDateDaySort_date |
1978-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ177071524 |
id |
NLEJ18050519X |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ18050519X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706130630.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1978 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ18050519X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ18050519X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1978</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Badelek, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Berthot, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Burq, J.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chemarin, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chevallier, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cotte, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dore, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Douhet, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dahlgren, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ekelof, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Grafstrom, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gajewski, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hagberg, E.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hallgren, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ille, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Jonsson, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kullander, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lambert, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Martin, J.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Maury, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Meritet, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nassalski, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Querrou, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Vazeille, F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">155(1978), 1-2, Seite 61-74</subfield><subfield code="w">(DE-627)NLEJ177071524</subfield><subfield code="w">(DE-600)2205646-4</subfield><subfield code="x">0029-554X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:155</subfield><subfield code="g">year:1978</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:61-74</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">155</subfield><subfield code="j">1978</subfield><subfield code="e">1-2</subfield><subfield code="h">61-74</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ177071524 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0029-554X |
topic_title |
Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
b b bb j b jb j b jb m c mc m c mc p c pc c d cd g d gd s d sd t e te p g pg w g wg e h eh a h ah b i bi s j sj s k sk m l ml j m jm s m sm l m lm j n jn m q mq f v fv |
hierarchy_parent_title |
Nuclear Instruments and Methods |
hierarchy_parent_id |
NLEJ177071524 |
hierarchy_top_title |
Nuclear Instruments and Methods |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ177071524 (DE-600)2205646-4 |
title |
Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
spellingShingle |
Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
ctrlnum |
(DE-627)NLEJ18050519X (DE-599)GBVNLZ18050519X |
title_full |
Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
journal |
Nuclear Instruments and Methods |
journalStr |
Nuclear Instruments and Methods |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1978 |
contenttype_str_mv |
zzz |
container_start_page |
61 |
container_volume |
155 |
format_se |
Elektronische Aufsätze |
title_sort |
spectrometers for measurements of recoils and scattered particles from 5 gev pion-helium interactions |
title_auth |
Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
abstract |
An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. |
abstractGer |
An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. |
abstract_unstemmed |
An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
1-2 |
title_short |
Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions |
url |
http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8 |
remote_bool |
true |
author2 |
Badelek, B. Berthot, J. Burq, J.P. Chemarin, M. Chevallier, M. Cotte, P. Dore, C. Douhet, G. Dahlgren, S. Ekelof, T. Grafstrom, P. Gajewski, W. Hagberg, E. Hallgren, A. Ille, B. Jonsson, S. Kullander, S. Lambert, M. Martin, J.P. Maury, S. Meritet, L. Nassalski, J. Querrou, M. Vazeille, F. |
author2Str |
Badelek, B. Berthot, J. Burq, J.P. Chemarin, M. Chevallier, M. Cotte, P. Dore, C. Douhet, G. Dahlgren, S. Ekelof, T. Grafstrom, P. Gajewski, W. Hagberg, E. Hallgren, A. Ille, B. Jonsson, S. Kullander, S. Lambert, M. Martin, J.P. Maury, S. Meritet, L. Nassalski, J. Querrou, M. Vazeille, F. |
ppnlink |
NLEJ177071524 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth |
up_date |
2024-07-06T03:37:00.835Z |
_version_ |
1803799254360129536 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ18050519X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706130630.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1978 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ18050519X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ18050519X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Spectrometers for measurements of recoils and scattered particles from 5 GeV pion-helium interactions</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1978</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">An apparatus, used to search for nucleon isobars, x, in π^4 He -> πtx or π^4 He -> π^3 Hex reactions, is described. The nuclear fragment and the scattered fast pion were measured in a recoil spectrometer and a fast-particle spectrometer, respectively.The recoil spectrometer has multiwire proportional chambers (MWPC) for the measurement of direction and semiconductor detectors and scintillation counters for the measurement of energy. The identification of the recoil is accomplished by means of the E, ΔE method. The target is gaseous to allow the measurement of low-energy recoils and it can hold pressures up to 150 atm. The spectrometer for the scattered pion consists of a magnet and MWPC's.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Badelek, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Berthot, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Burq, J.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chemarin, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Chevallier, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cotte, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dore, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Douhet, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dahlgren, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ekelof, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Grafstrom, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gajewski, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hagberg, E.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hallgren, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ille, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Jonsson, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kullander, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lambert, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Martin, J.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Maury, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Meritet, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Nassalski, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Querrou, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Vazeille, F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">155(1978), 1-2, Seite 61-74</subfield><subfield code="w">(DE-627)NLEJ177071524</subfield><subfield code="w">(DE-600)2205646-4</subfield><subfield code="x">0029-554X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:155</subfield><subfield code="g">year:1978</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:61-74</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0029-554X(78)90187-8</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">155</subfield><subfield code="j">1978</subfield><subfield code="e">1-2</subfield><subfield code="h">61-74</subfield></datafield></record></collection>
|
score |
7.400939 |