A surface ionization source for beam energy calibration
A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a pr...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1981 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods - Amsterdam : Elsevier, 189(1981), 2-3, Seite 351-356 |
Übergeordnetes Werk: |
volume:189 ; year:1981 ; number:2-3 ; pages:351-356 |
Links: |
---|
Katalog-ID: |
NLEJ180516140 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ180516140 | ||
003 | DE-627 | ||
005 | 20210706130802.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1981 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ180516140 | ||
035 | |a (DE-599)GBVNLZ180516140 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 2 | |a A surface ionization source for beam energy calibration |
264 | 1 | |c 1981 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Dyer, P. |4 oth | |
700 | 1 | |a Robertson, R.G.H. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods |d Amsterdam : Elsevier |g 189(1981), 2-3, Seite 351-356 |w (DE-627)NLEJ177071524 |w (DE-600)2205646-4 |x 0029-554X |7 nnns |
773 | 1 | 8 | |g volume:189 |g year:1981 |g number:2-3 |g pages:351-356 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 189 |j 1981 |e 2-3 |h 351-356 |
matchkey_str |
article:0029554X:1981----::sraeoiainoreobaeeg |
---|---|
hierarchy_sort_str |
1981 |
publishDate |
1981 |
allfields |
(DE-627)NLEJ180516140 (DE-599)GBVNLZ180516140 DE-627 ger DE-627 rakwb eng A surface ionization source for beam energy calibration 1981 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Dyer, P. oth Robertson, R.G.H. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 189(1981), 2-3, Seite 351-356 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:189 year:1981 number:2-3 pages:351-356 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 189 1981 2-3 351-356 |
spelling |
(DE-627)NLEJ180516140 (DE-599)GBVNLZ180516140 DE-627 ger DE-627 rakwb eng A surface ionization source for beam energy calibration 1981 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Dyer, P. oth Robertson, R.G.H. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 189(1981), 2-3, Seite 351-356 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:189 year:1981 number:2-3 pages:351-356 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 189 1981 2-3 351-356 |
allfields_unstemmed |
(DE-627)NLEJ180516140 (DE-599)GBVNLZ180516140 DE-627 ger DE-627 rakwb eng A surface ionization source for beam energy calibration 1981 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Dyer, P. oth Robertson, R.G.H. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 189(1981), 2-3, Seite 351-356 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:189 year:1981 number:2-3 pages:351-356 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 189 1981 2-3 351-356 |
allfieldsGer |
(DE-627)NLEJ180516140 (DE-599)GBVNLZ180516140 DE-627 ger DE-627 rakwb eng A surface ionization source for beam energy calibration 1981 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Dyer, P. oth Robertson, R.G.H. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 189(1981), 2-3, Seite 351-356 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:189 year:1981 number:2-3 pages:351-356 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 189 1981 2-3 351-356 |
allfieldsSound |
(DE-627)NLEJ180516140 (DE-599)GBVNLZ180516140 DE-627 ger DE-627 rakwb eng A surface ionization source for beam energy calibration 1981 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Dyer, P. oth Robertson, R.G.H. oth in Nuclear Instruments and Methods Amsterdam : Elsevier 189(1981), 2-3, Seite 351-356 (DE-627)NLEJ177071524 (DE-600)2205646-4 0029-554X nnns volume:189 year:1981 number:2-3 pages:351-356 http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 189 1981 2-3 351-356 |
language |
English |
source |
in Nuclear Instruments and Methods 189(1981), 2-3, Seite 351-356 volume:189 year:1981 number:2-3 pages:351-356 |
sourceStr |
in Nuclear Instruments and Methods 189(1981), 2-3, Seite 351-356 volume:189 year:1981 number:2-3 pages:351-356 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods |
authorswithroles_txt_mv |
Dyer, P. @@oth@@ Robertson, R.G.H. @@oth@@ |
publishDateDaySort_date |
1981-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ177071524 |
id |
NLEJ180516140 |
language_de |
englisch |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180516140</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706130802.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1981 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180516140</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180516140</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A surface ionization source for beam energy calibration</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1981</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dyer, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Robertson, R.G.H.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">189(1981), 2-3, Seite 351-356</subfield><subfield code="w">(DE-627)NLEJ177071524</subfield><subfield code="w">(DE-600)2205646-4</subfield><subfield code="x">0029-554X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:189</subfield><subfield code="g">year:1981</subfield><subfield code="g">number:2-3</subfield><subfield code="g">pages:351-356</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">189</subfield><subfield code="j">1981</subfield><subfield code="e">2-3</subfield><subfield code="h">351-356</subfield></datafield></record></collection>
|
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180516140</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706130802.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1981 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180516140</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180516140</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A surface ionization source for beam energy calibration</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1981</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Dyer, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Robertson, R.G.H.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">189(1981), 2-3, Seite 351-356</subfield><subfield code="w">(DE-627)NLEJ177071524</subfield><subfield code="w">(DE-600)2205646-4</subfield><subfield code="x">0029-554X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:189</subfield><subfield code="g">year:1981</subfield><subfield code="g">number:2-3</subfield><subfield code="g">pages:351-356</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">189</subfield><subfield code="j">1981</subfield><subfield code="e">2-3</subfield><subfield code="h">351-356</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ177071524 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0029-554X |
topic_title |
A surface ionization source for beam energy calibration |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
p d pd r r rr |
hierarchy_parent_title |
Nuclear Instruments and Methods |
hierarchy_parent_id |
NLEJ177071524 |
hierarchy_top_title |
Nuclear Instruments and Methods |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ177071524 (DE-600)2205646-4 |
title |
A surface ionization source for beam energy calibration |
spellingShingle |
A surface ionization source for beam energy calibration |
ctrlnum |
(DE-627)NLEJ180516140 (DE-599)GBVNLZ180516140 |
title_full |
A surface ionization source for beam energy calibration |
journal |
Nuclear Instruments and Methods |
journalStr |
Nuclear Instruments and Methods |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1981 |
contenttype_str_mv |
zzz |
container_start_page |
351 |
container_volume |
189 |
format_se |
Elektronische Aufsätze |
title_sort |
surface ionization source for beam energy calibration |
title_auth |
A surface ionization source for beam energy calibration |
abstract |
A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. |
abstractGer |
A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. |
abstract_unstemmed |
A surface ionization source has been constructed to produce Tl^+ ions having the same magnetic rigidity as light ions of a few MeV energy. The light-ion energy is determined by matching the paths of the light and Tl^+ ions through a magnetic spectrometer and by measuring the source voltage with a precision voltage divider and voltmeter. The absolute calibration has been verified by measuring the energy of alpha particles from a ^2^1^2Bi source and by measuring the ^1^4N(p, n)^1^4O reaction threshold. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
2-3 |
title_short |
A surface ionization source for beam energy calibration |
url |
http://linkinghub.elsevier.com/retrieve/pii/0029-554X(81)90415-8 |
remote_bool |
true |
author2 |
Dyer, P. Robertson, R.G.H. |
author2Str |
Dyer, P. Robertson, R.G.H. |
ppnlink |
NLEJ177071524 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
up_date |
2024-07-06T03:38:55.940Z |
_version_ |
1803799375055421440 |
score |
7.4007416 |