Some simple approaches used in the construction of multiwire proportional chambers
A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musi...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1983 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods In Physics Research - Amsterdam : Elsevier, 216(1983), 1-2, Seite 67-70 |
Übergeordnetes Werk: |
volume:216 ; year:1983 ; number:1-2 ; pages:67-70 |
Links: |
---|
Katalog-ID: |
NLEJ18060676X |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ18060676X | ||
003 | DE-627 | ||
005 | 20210706132130.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1983 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ18060676X | ||
035 | |a (DE-599)GBVNLZ18060676X | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Some simple approaches used in the construction of multiwire proportional chambers |
264 | 1 | |c 1983 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Staric, M. |4 oth | |
700 | 1 | |a Zavrtanik, D. |4 oth | |
700 | 1 | |a Kernel, G. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods In Physics Research |d Amsterdam : Elsevier |g 216(1983), 1-2, Seite 67-70 |w (DE-627)NLEJ180600451 |w (DE-600)1466532-3 |x 0167-5087 |7 nnns |
773 | 1 | 8 | |g volume:216 |g year:1983 |g number:1-2 |g pages:67-70 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 216 |j 1983 |e 1-2 |h 67-70 |
matchkey_str |
article:01675087:1983----::oeipeprahssdnhcntutoomliier |
---|---|
hierarchy_sort_str |
1983 |
publishDate |
1983 |
allfields |
(DE-627)NLEJ18060676X (DE-599)GBVNLZ18060676X DE-627 ger DE-627 rakwb eng Some simple approaches used in the construction of multiwire proportional chambers 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Staric, M. oth Zavrtanik, D. oth Kernel, G. oth in Nuclear Instruments and Methods In Physics Research Amsterdam : Elsevier 216(1983), 1-2, Seite 67-70 (DE-627)NLEJ180600451 (DE-600)1466532-3 0167-5087 nnns volume:216 year:1983 number:1-2 pages:67-70 http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 216 1983 1-2 67-70 |
spelling |
(DE-627)NLEJ18060676X (DE-599)GBVNLZ18060676X DE-627 ger DE-627 rakwb eng Some simple approaches used in the construction of multiwire proportional chambers 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Staric, M. oth Zavrtanik, D. oth Kernel, G. oth in Nuclear Instruments and Methods In Physics Research Amsterdam : Elsevier 216(1983), 1-2, Seite 67-70 (DE-627)NLEJ180600451 (DE-600)1466532-3 0167-5087 nnns volume:216 year:1983 number:1-2 pages:67-70 http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 216 1983 1-2 67-70 |
allfields_unstemmed |
(DE-627)NLEJ18060676X (DE-599)GBVNLZ18060676X DE-627 ger DE-627 rakwb eng Some simple approaches used in the construction of multiwire proportional chambers 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Staric, M. oth Zavrtanik, D. oth Kernel, G. oth in Nuclear Instruments and Methods In Physics Research Amsterdam : Elsevier 216(1983), 1-2, Seite 67-70 (DE-627)NLEJ180600451 (DE-600)1466532-3 0167-5087 nnns volume:216 year:1983 number:1-2 pages:67-70 http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 216 1983 1-2 67-70 |
allfieldsGer |
(DE-627)NLEJ18060676X (DE-599)GBVNLZ18060676X DE-627 ger DE-627 rakwb eng Some simple approaches used in the construction of multiwire proportional chambers 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Staric, M. oth Zavrtanik, D. oth Kernel, G. oth in Nuclear Instruments and Methods In Physics Research Amsterdam : Elsevier 216(1983), 1-2, Seite 67-70 (DE-627)NLEJ180600451 (DE-600)1466532-3 0167-5087 nnns volume:216 year:1983 number:1-2 pages:67-70 http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 216 1983 1-2 67-70 |
allfieldsSound |
(DE-627)NLEJ18060676X (DE-599)GBVNLZ18060676X DE-627 ger DE-627 rakwb eng Some simple approaches used in the construction of multiwire proportional chambers 1983 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Staric, M. oth Zavrtanik, D. oth Kernel, G. oth in Nuclear Instruments and Methods In Physics Research Amsterdam : Elsevier 216(1983), 1-2, Seite 67-70 (DE-627)NLEJ180600451 (DE-600)1466532-3 0167-5087 nnns volume:216 year:1983 number:1-2 pages:67-70 http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 216 1983 1-2 67-70 |
language |
English |
source |
in Nuclear Instruments and Methods In Physics Research 216(1983), 1-2, Seite 67-70 volume:216 year:1983 number:1-2 pages:67-70 |
sourceStr |
in Nuclear Instruments and Methods In Physics Research 216(1983), 1-2, Seite 67-70 volume:216 year:1983 number:1-2 pages:67-70 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods In Physics Research |
authorswithroles_txt_mv |
Staric, M. @@oth@@ Zavrtanik, D. @@oth@@ Kernel, G. @@oth@@ |
publishDateDaySort_date |
1983-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ180600451 |
id |
NLEJ18060676X |
language_de |
englisch |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ18060676X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706132130.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1983 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ18060676X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ18060676X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Some simple approaches used in the construction of multiwire proportional chambers</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1983</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Staric, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zavrtanik, D.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kernel, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods In Physics Research</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">216(1983), 1-2, Seite 67-70</subfield><subfield code="w">(DE-627)NLEJ180600451</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0167-5087</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:216</subfield><subfield code="g">year:1983</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:67-70</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">216</subfield><subfield code="j">1983</subfield><subfield code="e">1-2</subfield><subfield code="h">67-70</subfield></datafield></record></collection>
|
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ18060676X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706132130.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1983 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ18060676X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ18060676X</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Some simple approaches used in the construction of multiwire proportional chambers</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1983</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Staric, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zavrtanik, D.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kernel, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods In Physics Research</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">216(1983), 1-2, Seite 67-70</subfield><subfield code="w">(DE-627)NLEJ180600451</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0167-5087</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:216</subfield><subfield code="g">year:1983</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:67-70</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">216</subfield><subfield code="j">1983</subfield><subfield code="e">1-2</subfield><subfield code="h">67-70</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ180600451 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0167-5087 |
topic_title |
Some simple approaches used in the construction of multiwire proportional chambers |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
m s ms d z dz g k gk |
hierarchy_parent_title |
Nuclear Instruments and Methods In Physics Research |
hierarchy_parent_id |
NLEJ180600451 |
hierarchy_top_title |
Nuclear Instruments and Methods In Physics Research |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ180600451 (DE-600)1466532-3 |
title |
Some simple approaches used in the construction of multiwire proportional chambers |
spellingShingle |
Some simple approaches used in the construction of multiwire proportional chambers |
ctrlnum |
(DE-627)NLEJ18060676X (DE-599)GBVNLZ18060676X |
title_full |
Some simple approaches used in the construction of multiwire proportional chambers |
journal |
Nuclear Instruments and Methods In Physics Research |
journalStr |
Nuclear Instruments and Methods In Physics Research |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1983 |
contenttype_str_mv |
zzz |
container_start_page |
67 |
container_volume |
216 |
format_se |
Elektronische Aufsätze |
title_sort |
some simple approaches used in the construction of multiwire proportional chambers |
title_auth |
Some simple approaches used in the construction of multiwire proportional chambers |
abstract |
A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. |
abstractGer |
A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. |
abstract_unstemmed |
A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mm x 160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
1-2 |
title_short |
Some simple approaches used in the construction of multiwire proportional chambers |
url |
http://linkinghub.elsevier.com/retrieve/pii/0167-5087(83)90331-9 |
remote_bool |
true |
author2 |
Staric, M. Zavrtanik, D. Kernel, G. |
author2Str |
Staric, M. Zavrtanik, D. Kernel, G. |
ppnlink |
NLEJ180600451 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth |
up_date |
2024-07-06T03:55:15.815Z |
_version_ |
1803800402526732288 |
score |
7.398114 |