Comments on ''on the energy resolution of uranium and other hadron calorimeters''
The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of '...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1989 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods in Physics Research Section A: - Amsterdam : Elsevier, 275(1989), 1, Seite 190-191 |
Übergeordnetes Werk: |
volume:275 ; year:1989 ; number:1 ; pages:190-191 |
Links: |
---|
Katalog-ID: |
NLEJ180860852 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ180860852 | ||
003 | DE-627 | ||
005 | 20210706140016.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1989 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ180860852 | ||
035 | |a (DE-599)GBVNLZ180860852 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
264 | 1 | |c 1989 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Brau, J.E. |4 oth | |
700 | 1 | |a Gabriel, T.A. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods in Physics Research Section A: |d Amsterdam : Elsevier |g 275(1989), 1, Seite 190-191 |w (DE-627)NLEJ180854372 |w (DE-600)1466532-3 |x 0168-9002 |7 nnns |
773 | 1 | 8 | |g volume:275 |g year:1989 |g number:1 |g pages:190-191 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 275 |j 1989 |e 1 |h 190-191 |
matchkey_str |
article:01689002:1989----::omnsnnheegrsltoouaimnohr |
---|---|
hierarchy_sort_str |
1989 |
publishDate |
1989 |
allfields |
(DE-627)NLEJ180860852 (DE-599)GBVNLZ180860852 DE-627 ger DE-627 rakwb eng Comments on ''on the energy resolution of uranium and other hadron calorimeters'' 1989 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Brau, J.E. oth Gabriel, T.A. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 275(1989), 1, Seite 190-191 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:275 year:1989 number:1 pages:190-191 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 275 1989 1 190-191 |
spelling |
(DE-627)NLEJ180860852 (DE-599)GBVNLZ180860852 DE-627 ger DE-627 rakwb eng Comments on ''on the energy resolution of uranium and other hadron calorimeters'' 1989 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Brau, J.E. oth Gabriel, T.A. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 275(1989), 1, Seite 190-191 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:275 year:1989 number:1 pages:190-191 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 275 1989 1 190-191 |
allfields_unstemmed |
(DE-627)NLEJ180860852 (DE-599)GBVNLZ180860852 DE-627 ger DE-627 rakwb eng Comments on ''on the energy resolution of uranium and other hadron calorimeters'' 1989 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Brau, J.E. oth Gabriel, T.A. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 275(1989), 1, Seite 190-191 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:275 year:1989 number:1 pages:190-191 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 275 1989 1 190-191 |
allfieldsGer |
(DE-627)NLEJ180860852 (DE-599)GBVNLZ180860852 DE-627 ger DE-627 rakwb eng Comments on ''on the energy resolution of uranium and other hadron calorimeters'' 1989 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Brau, J.E. oth Gabriel, T.A. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 275(1989), 1, Seite 190-191 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:275 year:1989 number:1 pages:190-191 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 275 1989 1 190-191 |
allfieldsSound |
(DE-627)NLEJ180860852 (DE-599)GBVNLZ180860852 DE-627 ger DE-627 rakwb eng Comments on ''on the energy resolution of uranium and other hadron calorimeters'' 1989 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Brau, J.E. oth Gabriel, T.A. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 275(1989), 1, Seite 190-191 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:275 year:1989 number:1 pages:190-191 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 275 1989 1 190-191 |
language |
English |
source |
in Nuclear Instruments and Methods in Physics Research Section A: 275(1989), 1, Seite 190-191 volume:275 year:1989 number:1 pages:190-191 |
sourceStr |
in Nuclear Instruments and Methods in Physics Research Section A: 275(1989), 1, Seite 190-191 volume:275 year:1989 number:1 pages:190-191 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods in Physics Research Section A: |
authorswithroles_txt_mv |
Brau, J.E. @@oth@@ Gabriel, T.A. @@oth@@ |
publishDateDaySort_date |
1989-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ180854372 |
id |
NLEJ180860852 |
language_de |
englisch |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180860852</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706140016.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1989 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180860852</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180860852</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Comments on ''on the energy resolution of uranium and other hadron calorimeters''</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1989</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Brau, J.E.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gabriel, T.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">275(1989), 1, Seite 190-191</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:275</subfield><subfield code="g">year:1989</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:190-191</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">275</subfield><subfield code="j">1989</subfield><subfield code="e">1</subfield><subfield code="h">190-191</subfield></datafield></record></collection>
|
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180860852</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706140016.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1989 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180860852</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180860852</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Comments on ''on the energy resolution of uranium and other hadron calorimeters''</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1989</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Brau, J.E.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gabriel, T.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">275(1989), 1, Seite 190-191</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:275</subfield><subfield code="g">year:1989</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:190-191</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">275</subfield><subfield code="j">1989</subfield><subfield code="e">1</subfield><subfield code="h">190-191</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ180854372 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0168-9002 |
topic_title |
Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
j b jb t g tg |
hierarchy_parent_title |
Nuclear Instruments and Methods in Physics Research Section A: |
hierarchy_parent_id |
NLEJ180854372 |
hierarchy_top_title |
Nuclear Instruments and Methods in Physics Research Section A: |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ180854372 (DE-600)1466532-3 |
title |
Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
spellingShingle |
Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
ctrlnum |
(DE-627)NLEJ180860852 (DE-599)GBVNLZ180860852 |
title_full |
Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
journal |
Nuclear Instruments and Methods in Physics Research Section A: |
journalStr |
Nuclear Instruments and Methods in Physics Research Section A: |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1989 |
contenttype_str_mv |
zzz |
container_start_page |
190 |
container_volume |
275 |
format_se |
Elektronische Aufsätze |
title_sort |
comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
title_auth |
Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
abstract |
The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. |
abstractGer |
The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. |
abstract_unstemmed |
The key phenomena contributing to the performance of uranium calorimeters as described by R. Wigmans [Nucl. Instr. and Meth. A259 (1987) 389] are the same we identified in our work two years earlier. Our earlier publications stressed the importance of hydrogen in the active medium, the role of ''electromagnetic sampling inefficiencies'', the consequences of saturation, and concluded that lead calorimeters might be made compensating. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
1 |
title_short |
Comments on ''on the energy resolution of uranium and other hadron calorimeters'' |
url |
http://linkinghub.elsevier.com/retrieve/pii/0168-9002(89)90351-3 |
remote_bool |
true |
author2 |
Brau, J.E. Gabriel, T.A. |
author2Str |
Brau, J.E. Gabriel, T.A. |
ppnlink |
NLEJ180854372 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
up_date |
2024-07-06T04:43:11.827Z |
_version_ |
1803803418244939776 |
score |
7.4011803 |