Investigation of an electromagnetic calorimeter based on liquid krypton
Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1990 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods in Physics Research Section A: - Amsterdam : Elsevier, 289(1990), 3, Seite 468-474 |
Übergeordnetes Werk: |
volume:289 ; year:1990 ; number:3 ; pages:468-474 |
Links: |
---|
Katalog-ID: |
NLEJ180882716 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ180882716 | ||
003 | DE-627 | ||
005 | 20210706140334.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1990 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ180882716 | ||
035 | |a (DE-599)GBVNLZ180882716 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Investigation of an electromagnetic calorimeter based on liquid krypton |
264 | 1 | |c 1990 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Aulchenko, V.M. |4 oth | |
700 | 1 | |a Klimenko, S.G. |4 oth | |
700 | 1 | |a Kolachev, G.M. |4 oth | |
700 | 1 | |a Leontiev, L.A. |4 oth | |
700 | 1 | |a Onuchin, A.P. |4 oth | |
700 | 1 | |a Panin, V.S. |4 oth | |
700 | 1 | |a Pril, Y.V. |4 oth | |
700 | 1 | |a Rodyakin, V.A. |4 oth | |
700 | 1 | |a Rylin, A.V. |4 oth | |
700 | 1 | |a Tayursky, V.A. |4 oth | |
700 | 1 | |a Tikhonov, Y.A. |4 oth | |
700 | 1 | |a Cantoni, P. |4 oth | |
700 | 1 | |a Frabetti, P.L. |4 oth | |
700 | 1 | |a Stagni, L. |4 oth | |
700 | 1 | |a Lo Bianco, G. |4 oth | |
700 | 1 | |a Palombo, F. |4 oth | |
700 | 1 | |a Manfredi, P.F. |4 oth | |
700 | 1 | |a Re, V. |4 oth | |
700 | 1 | |a Speziali, V. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods in Physics Research Section A: |d Amsterdam : Elsevier |g 289(1990), 3, Seite 468-474 |w (DE-627)NLEJ180854372 |w (DE-600)1466532-3 |x 0168-9002 |7 nnns |
773 | 1 | 8 | |g volume:289 |g year:1990 |g number:3 |g pages:468-474 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 289 |j 1990 |e 3 |h 468-474 |
matchkey_str |
article:01689002:1990----::netgtooaeetoantcaoieeb |
---|---|
hierarchy_sort_str |
1990 |
publishDate |
1990 |
allfields |
(DE-627)NLEJ180882716 (DE-599)GBVNLZ180882716 DE-627 ger DE-627 rakwb eng Investigation of an electromagnetic calorimeter based on liquid krypton 1990 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Aulchenko, V.M. oth Klimenko, S.G. oth Kolachev, G.M. oth Leontiev, L.A. oth Onuchin, A.P. oth Panin, V.S. oth Pril, Y.V. oth Rodyakin, V.A. oth Rylin, A.V. oth Tayursky, V.A. oth Tikhonov, Y.A. oth Cantoni, P. oth Frabetti, P.L. oth Stagni, L. oth Lo Bianco, G. oth Palombo, F. oth Manfredi, P.F. oth Re, V. oth Speziali, V. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 289(1990), 3, Seite 468-474 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:289 year:1990 number:3 pages:468-474 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 289 1990 3 468-474 |
spelling |
(DE-627)NLEJ180882716 (DE-599)GBVNLZ180882716 DE-627 ger DE-627 rakwb eng Investigation of an electromagnetic calorimeter based on liquid krypton 1990 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Aulchenko, V.M. oth Klimenko, S.G. oth Kolachev, G.M. oth Leontiev, L.A. oth Onuchin, A.P. oth Panin, V.S. oth Pril, Y.V. oth Rodyakin, V.A. oth Rylin, A.V. oth Tayursky, V.A. oth Tikhonov, Y.A. oth Cantoni, P. oth Frabetti, P.L. oth Stagni, L. oth Lo Bianco, G. oth Palombo, F. oth Manfredi, P.F. oth Re, V. oth Speziali, V. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 289(1990), 3, Seite 468-474 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:289 year:1990 number:3 pages:468-474 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 289 1990 3 468-474 |
allfields_unstemmed |
(DE-627)NLEJ180882716 (DE-599)GBVNLZ180882716 DE-627 ger DE-627 rakwb eng Investigation of an electromagnetic calorimeter based on liquid krypton 1990 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Aulchenko, V.M. oth Klimenko, S.G. oth Kolachev, G.M. oth Leontiev, L.A. oth Onuchin, A.P. oth Panin, V.S. oth Pril, Y.V. oth Rodyakin, V.A. oth Rylin, A.V. oth Tayursky, V.A. oth Tikhonov, Y.A. oth Cantoni, P. oth Frabetti, P.L. oth Stagni, L. oth Lo Bianco, G. oth Palombo, F. oth Manfredi, P.F. oth Re, V. oth Speziali, V. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 289(1990), 3, Seite 468-474 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:289 year:1990 number:3 pages:468-474 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 289 1990 3 468-474 |
allfieldsGer |
(DE-627)NLEJ180882716 (DE-599)GBVNLZ180882716 DE-627 ger DE-627 rakwb eng Investigation of an electromagnetic calorimeter based on liquid krypton 1990 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Aulchenko, V.M. oth Klimenko, S.G. oth Kolachev, G.M. oth Leontiev, L.A. oth Onuchin, A.P. oth Panin, V.S. oth Pril, Y.V. oth Rodyakin, V.A. oth Rylin, A.V. oth Tayursky, V.A. oth Tikhonov, Y.A. oth Cantoni, P. oth Frabetti, P.L. oth Stagni, L. oth Lo Bianco, G. oth Palombo, F. oth Manfredi, P.F. oth Re, V. oth Speziali, V. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 289(1990), 3, Seite 468-474 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:289 year:1990 number:3 pages:468-474 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 289 1990 3 468-474 |
allfieldsSound |
(DE-627)NLEJ180882716 (DE-599)GBVNLZ180882716 DE-627 ger DE-627 rakwb eng Investigation of an electromagnetic calorimeter based on liquid krypton 1990 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Aulchenko, V.M. oth Klimenko, S.G. oth Kolachev, G.M. oth Leontiev, L.A. oth Onuchin, A.P. oth Panin, V.S. oth Pril, Y.V. oth Rodyakin, V.A. oth Rylin, A.V. oth Tayursky, V.A. oth Tikhonov, Y.A. oth Cantoni, P. oth Frabetti, P.L. oth Stagni, L. oth Lo Bianco, G. oth Palombo, F. oth Manfredi, P.F. oth Re, V. oth Speziali, V. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 289(1990), 3, Seite 468-474 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:289 year:1990 number:3 pages:468-474 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 289 1990 3 468-474 |
language |
English |
source |
in Nuclear Instruments and Methods in Physics Research Section A: 289(1990), 3, Seite 468-474 volume:289 year:1990 number:3 pages:468-474 |
sourceStr |
in Nuclear Instruments and Methods in Physics Research Section A: 289(1990), 3, Seite 468-474 volume:289 year:1990 number:3 pages:468-474 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods in Physics Research Section A: |
authorswithroles_txt_mv |
Aulchenko, V.M. @@oth@@ Klimenko, S.G. @@oth@@ Kolachev, G.M. @@oth@@ Leontiev, L.A. @@oth@@ Onuchin, A.P. @@oth@@ Panin, V.S. @@oth@@ Pril, Y.V. @@oth@@ Rodyakin, V.A. @@oth@@ Rylin, A.V. @@oth@@ Tayursky, V.A. @@oth@@ Tikhonov, Y.A. @@oth@@ Cantoni, P. @@oth@@ Frabetti, P.L. @@oth@@ Stagni, L. @@oth@@ Lo Bianco, G. @@oth@@ Palombo, F. @@oth@@ Manfredi, P.F. @@oth@@ Re, V. @@oth@@ Speziali, V. @@oth@@ |
publishDateDaySort_date |
1990-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ180854372 |
id |
NLEJ180882716 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180882716</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706140334.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1990 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180882716</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180882716</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Investigation of an electromagnetic calorimeter based on liquid krypton</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1990</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Aulchenko, V.M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Klimenko, S.G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kolachev, G.M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Leontiev, L.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Onuchin, A.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Panin, V.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pril, Y.V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rodyakin, V.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rylin, A.V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tayursky, V.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tikhonov, Y.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cantoni, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Frabetti, P.L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Stagni, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lo Bianco, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Palombo, F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Manfredi, P.F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Re, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Speziali, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">289(1990), 3, Seite 468-474</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:289</subfield><subfield code="g">year:1990</subfield><subfield code="g">number:3</subfield><subfield code="g">pages:468-474</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">289</subfield><subfield code="j">1990</subfield><subfield code="e">3</subfield><subfield code="h">468-474</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ180854372 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0168-9002 |
topic_title |
Investigation of an electromagnetic calorimeter based on liquid krypton |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
v a va s k sk g k gk l l ll a o ao v p vp y p yp v r vr a r ar v t vt y t yt p c pc p f pf l s ls b g l bg bgl f p fp p m pm v r vr v s vs |
hierarchy_parent_title |
Nuclear Instruments and Methods in Physics Research Section A: |
hierarchy_parent_id |
NLEJ180854372 |
hierarchy_top_title |
Nuclear Instruments and Methods in Physics Research Section A: |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ180854372 (DE-600)1466532-3 |
title |
Investigation of an electromagnetic calorimeter based on liquid krypton |
spellingShingle |
Investigation of an electromagnetic calorimeter based on liquid krypton |
ctrlnum |
(DE-627)NLEJ180882716 (DE-599)GBVNLZ180882716 |
title_full |
Investigation of an electromagnetic calorimeter based on liquid krypton |
journal |
Nuclear Instruments and Methods in Physics Research Section A: |
journalStr |
Nuclear Instruments and Methods in Physics Research Section A: |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1990 |
contenttype_str_mv |
zzz |
container_start_page |
468 |
container_volume |
289 |
format_se |
Elektronische Aufsätze |
title_sort |
investigation of an electromagnetic calorimeter based on liquid krypton |
title_auth |
Investigation of an electromagnetic calorimeter based on liquid krypton |
abstract |
Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. |
abstractGer |
Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. |
abstract_unstemmed |
Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
3 |
title_short |
Investigation of an electromagnetic calorimeter based on liquid krypton |
url |
http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G |
remote_bool |
true |
author2 |
Aulchenko, V.M. Klimenko, S.G. Kolachev, G.M. Leontiev, L.A. Onuchin, A.P. Panin, V.S. Pril, Y.V. Rodyakin, V.A. Rylin, A.V. Tayursky, V.A. Tikhonov, Y.A. Cantoni, P. Frabetti, P.L. Stagni, L. Lo Bianco, G. Palombo, F. Manfredi, P.F. Re, V. Speziali, V. |
author2Str |
Aulchenko, V.M. Klimenko, S.G. Kolachev, G.M. Leontiev, L.A. Onuchin, A.P. Panin, V.S. Pril, Y.V. Rodyakin, V.A. Rylin, A.V. Tayursky, V.A. Tikhonov, Y.A. Cantoni, P. Frabetti, P.L. Stagni, L. Lo Bianco, G. Palombo, F. Manfredi, P.F. Re, V. Speziali, V. |
ppnlink |
NLEJ180854372 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth |
up_date |
2024-07-06T04:47:52.683Z |
_version_ |
1803803712744849409 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180882716</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706140334.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1990 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180882716</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180882716</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Investigation of an electromagnetic calorimeter based on liquid krypton</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1990</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Effects determining the energy and spatial resolution of a calorimeter based on liquid krypton have been studied. With cathode strips of 10 mm a spatial resolution of 0.4 mm has been obtained in a cosmic rays test. The energy resolution of the calorimeter (0.4 ton of krypton) has been measured with positrons, achieving a rms of 5.7% at E = 130 MeV and 1.7% at E = 1200 MeV. The measurements are compared to Monte Carlo simulations.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Aulchenko, V.M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Klimenko, S.G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kolachev, G.M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Leontiev, L.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Onuchin, A.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Panin, V.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pril, Y.V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rodyakin, V.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rylin, A.V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tayursky, V.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tikhonov, Y.A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Cantoni, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Frabetti, P.L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Stagni, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lo Bianco, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Palombo, F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Manfredi, P.F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Re, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Speziali, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">289(1990), 3, Seite 468-474</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:289</subfield><subfield code="g">year:1990</subfield><subfield code="g">number:3</subfield><subfield code="g">pages:468-474</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(90)91518-G</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">289</subfield><subfield code="j">1990</subfield><subfield code="e">3</subfield><subfield code="h">468-474</subfield></datafield></record></collection>
|
score |
7.4012003 |