The construction and performance of a large cylindrical wire chamber with cathode readout
The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1992 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods in Physics Research Section A: - Amsterdam : Elsevier, 323(1992), 1-2, Seite 162-168 |
Übergeordnetes Werk: |
volume:323 ; year:1992 ; number:1-2 ; pages:162-168 |
Links: |
---|
Katalog-ID: |
NLEJ180925741 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ180925741 | ||
003 | DE-627 | ||
005 | 20210706141019.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1992 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ180925741 | ||
035 | |a (DE-599)GBVNLZ180925741 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 4 | |a The construction and performance of a large cylindrical wire chamber with cathode readout |
264 | 1 | |c 1992 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Deiters, K. |4 oth | |
700 | 1 | |a Donat, A. |4 oth | |
700 | 1 | |a Friebel, W. |4 oth | |
700 | 1 | |a Heller, R. |4 oth | |
700 | 1 | |a Kirsch, S. |4 oth | |
700 | 1 | |a Krankenhagen, R. |4 oth | |
700 | 1 | |a Lange, W. |4 oth | |
700 | 1 | |a Leiste, R. |4 oth | |
700 | 1 | |a Lohmann, W. |4 oth | |
700 | 1 | |a Lustermann, W. |4 oth | |
700 | 1 | |a Peng, Y. |4 oth | |
700 | 1 | |a Roser, U. |4 oth | |
700 | 1 | |a Tonisch, F. |4 oth | |
700 | 1 | |a Trowitzsch, G. |4 oth | |
700 | 1 | |a Vogt, H. |4 oth | |
700 | 1 | |a Wilhelmi, M. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods in Physics Research Section A: |d Amsterdam : Elsevier |g 323(1992), 1-2, Seite 162-168 |w (DE-627)NLEJ180854372 |w (DE-600)1466532-3 |x 0168-9002 |7 nnns |
773 | 1 | 8 | |g volume:323 |g year:1992 |g number:1-2 |g pages:162-168 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 323 |j 1992 |e 1-2 |h 162-168 |
matchkey_str |
article:01689002:1992----::hcntutoadefracoaagclnrcliehm |
---|---|
hierarchy_sort_str |
1992 |
publishDate |
1992 |
allfields |
(DE-627)NLEJ180925741 (DE-599)GBVNLZ180925741 DE-627 ger DE-627 rakwb eng The construction and performance of a large cylindrical wire chamber with cathode readout 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Deiters, K. oth Donat, A. oth Friebel, W. oth Heller, R. oth Kirsch, S. oth Krankenhagen, R. oth Lange, W. oth Leiste, R. oth Lohmann, W. oth Lustermann, W. oth Peng, Y. oth Roser, U. oth Tonisch, F. oth Trowitzsch, G. oth Vogt, H. oth Wilhelmi, M. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 323(1992), 1-2, Seite 162-168 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:323 year:1992 number:1-2 pages:162-168 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 323 1992 1-2 162-168 |
spelling |
(DE-627)NLEJ180925741 (DE-599)GBVNLZ180925741 DE-627 ger DE-627 rakwb eng The construction and performance of a large cylindrical wire chamber with cathode readout 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Deiters, K. oth Donat, A. oth Friebel, W. oth Heller, R. oth Kirsch, S. oth Krankenhagen, R. oth Lange, W. oth Leiste, R. oth Lohmann, W. oth Lustermann, W. oth Peng, Y. oth Roser, U. oth Tonisch, F. oth Trowitzsch, G. oth Vogt, H. oth Wilhelmi, M. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 323(1992), 1-2, Seite 162-168 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:323 year:1992 number:1-2 pages:162-168 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 323 1992 1-2 162-168 |
allfields_unstemmed |
(DE-627)NLEJ180925741 (DE-599)GBVNLZ180925741 DE-627 ger DE-627 rakwb eng The construction and performance of a large cylindrical wire chamber with cathode readout 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Deiters, K. oth Donat, A. oth Friebel, W. oth Heller, R. oth Kirsch, S. oth Krankenhagen, R. oth Lange, W. oth Leiste, R. oth Lohmann, W. oth Lustermann, W. oth Peng, Y. oth Roser, U. oth Tonisch, F. oth Trowitzsch, G. oth Vogt, H. oth Wilhelmi, M. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 323(1992), 1-2, Seite 162-168 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:323 year:1992 number:1-2 pages:162-168 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 323 1992 1-2 162-168 |
allfieldsGer |
(DE-627)NLEJ180925741 (DE-599)GBVNLZ180925741 DE-627 ger DE-627 rakwb eng The construction and performance of a large cylindrical wire chamber with cathode readout 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Deiters, K. oth Donat, A. oth Friebel, W. oth Heller, R. oth Kirsch, S. oth Krankenhagen, R. oth Lange, W. oth Leiste, R. oth Lohmann, W. oth Lustermann, W. oth Peng, Y. oth Roser, U. oth Tonisch, F. oth Trowitzsch, G. oth Vogt, H. oth Wilhelmi, M. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 323(1992), 1-2, Seite 162-168 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:323 year:1992 number:1-2 pages:162-168 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 323 1992 1-2 162-168 |
allfieldsSound |
(DE-627)NLEJ180925741 (DE-599)GBVNLZ180925741 DE-627 ger DE-627 rakwb eng The construction and performance of a large cylindrical wire chamber with cathode readout 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Deiters, K. oth Donat, A. oth Friebel, W. oth Heller, R. oth Kirsch, S. oth Krankenhagen, R. oth Lange, W. oth Leiste, R. oth Lohmann, W. oth Lustermann, W. oth Peng, Y. oth Roser, U. oth Tonisch, F. oth Trowitzsch, G. oth Vogt, H. oth Wilhelmi, M. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 323(1992), 1-2, Seite 162-168 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:323 year:1992 number:1-2 pages:162-168 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 323 1992 1-2 162-168 |
language |
English |
source |
in Nuclear Instruments and Methods in Physics Research Section A: 323(1992), 1-2, Seite 162-168 volume:323 year:1992 number:1-2 pages:162-168 |
sourceStr |
in Nuclear Instruments and Methods in Physics Research Section A: 323(1992), 1-2, Seite 162-168 volume:323 year:1992 number:1-2 pages:162-168 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods in Physics Research Section A: |
authorswithroles_txt_mv |
Deiters, K. @@oth@@ Donat, A. @@oth@@ Friebel, W. @@oth@@ Heller, R. @@oth@@ Kirsch, S. @@oth@@ Krankenhagen, R. @@oth@@ Lange, W. @@oth@@ Leiste, R. @@oth@@ Lohmann, W. @@oth@@ Lustermann, W. @@oth@@ Peng, Y. @@oth@@ Roser, U. @@oth@@ Tonisch, F. @@oth@@ Trowitzsch, G. @@oth@@ Vogt, H. @@oth@@ Wilhelmi, M. @@oth@@ |
publishDateDaySort_date |
1992-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ180854372 |
id |
NLEJ180925741 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180925741</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706141019.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1992 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180925741</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180925741</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="4"><subfield code="a">The construction and performance of a large cylindrical wire chamber with cathode readout</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1992</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Deiters, K.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Donat, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Friebel, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Heller, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kirsch, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Krankenhagen, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lange, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Leiste, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lohmann, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lustermann, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Peng, Y.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Roser, U.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tonisch, F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Trowitzsch, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Vogt, H.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wilhelmi, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">323(1992), 1-2, Seite 162-168</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:323</subfield><subfield code="g">year:1992</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:162-168</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">323</subfield><subfield code="j">1992</subfield><subfield code="e">1-2</subfield><subfield code="h">162-168</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ180854372 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0168-9002 |
topic_title |
The construction and performance of a large cylindrical wire chamber with cathode readout |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
k d kd a d ad w f wf r h rh s k sk r k rk w l wl r l rl w l wl w l wl y p yp u r ur f t ft g t gt h v hv m w mw |
hierarchy_parent_title |
Nuclear Instruments and Methods in Physics Research Section A: |
hierarchy_parent_id |
NLEJ180854372 |
hierarchy_top_title |
Nuclear Instruments and Methods in Physics Research Section A: |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ180854372 (DE-600)1466532-3 |
title |
The construction and performance of a large cylindrical wire chamber with cathode readout |
spellingShingle |
The construction and performance of a large cylindrical wire chamber with cathode readout |
ctrlnum |
(DE-627)NLEJ180925741 (DE-599)GBVNLZ180925741 |
title_full |
The construction and performance of a large cylindrical wire chamber with cathode readout |
journal |
Nuclear Instruments and Methods in Physics Research Section A: |
journalStr |
Nuclear Instruments and Methods in Physics Research Section A: |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1992 |
contenttype_str_mv |
zzz |
container_start_page |
162 |
container_volume |
323 |
format_se |
Elektronische Aufsätze |
title_sort |
construction and performance of a large cylindrical wire chamber with cathode readout |
title_auth |
The construction and performance of a large cylindrical wire chamber with cathode readout |
abstract |
The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. |
abstractGer |
The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. |
abstract_unstemmed |
The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
1-2 |
title_short |
The construction and performance of a large cylindrical wire chamber with cathode readout |
url |
http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A |
remote_bool |
true |
author2 |
Deiters, K. Donat, A. Friebel, W. Heller, R. Kirsch, S. Krankenhagen, R. Lange, W. Leiste, R. Lohmann, W. Lustermann, W. Peng, Y. Roser, U. Tonisch, F. Trowitzsch, G. Vogt, H. Wilhelmi, M. |
author2Str |
Deiters, K. Donat, A. Friebel, W. Heller, R. Kirsch, S. Krankenhagen, R. Lange, W. Leiste, R. Lohmann, W. Lustermann, W. Peng, Y. Roser, U. Tonisch, F. Trowitzsch, G. Vogt, H. Wilhelmi, M. |
ppnlink |
NLEJ180854372 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth |
up_date |
2024-07-06T04:57:04.738Z |
_version_ |
1803804291618570240 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180925741</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706141019.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1992 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180925741</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180925741</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="4"><subfield code="a">The construction and performance of a large cylindrical wire chamber with cathode readout</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1992</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The construction and performance of two large coaxial cylindrical multiwire proportional chambers with cathode readout, denoted as Z-detector, forming the outer part of the L3 central tracking detector, are described. Three self-supporting cylinders of about 1 m length and 1 m diameter, constructed as a sandwich of Kapton foil and foam, form the mechanical frame. In each chamber one cathode layer is subdivided into helical strips and the other one in rings. The readout of the charges induced on the cathode strips provides the avalanche position along the beam (z) direction. The detector has been running in the L3 experiment at LEP for nearly two years. The resolution of the z-measurement is 320 μm, the double track resolution is 10 mm. The efficiency of each chamber is 96%.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Deiters, K.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Donat, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Friebel, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Heller, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kirsch, S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Krankenhagen, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lange, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Leiste, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lohmann, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lustermann, W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Peng, Y.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Roser, U.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tonisch, F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Trowitzsch, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Vogt, H.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wilhelmi, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">323(1992), 1-2, Seite 162-168</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:323</subfield><subfield code="g">year:1992</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:162-168</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90283-A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">323</subfield><subfield code="j">1992</subfield><subfield code="e">1-2</subfield><subfield code="h">162-168</subfield></datafield></record></collection>
|
score |
7.4001474 |