A muon identification detector for B-physics near e^+e^- -> BB threshold
We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1992 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods in Physics Research Section A: - Amsterdam : Elsevier, 320(1992), 1-2, Seite 114-127 |
Übergeordnetes Werk: |
volume:320 ; year:1992 ; number:1-2 ; pages:114-127 |
Links: |
---|
Katalog-ID: |
NLEJ180949055 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ180949055 | ||
003 | DE-627 | ||
005 | 20210706141353.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1992 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ180949055 | ||
035 | |a (DE-599)GBVNLZ180949055 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 2 | |a A muon identification detector for B-physics near e^+e^- -> BB threshold |
264 | 1 | |c 1992 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Bortoletto, D. |4 oth | |
700 | 1 | |a Buda, L. |4 oth | |
700 | 1 | |a Ennulat, J. |4 oth | |
700 | 1 | |a Goldberg, M. |4 oth | |
700 | 1 | |a Haupt, T. |4 oth | |
700 | 1 | |a Holmes, R. |4 oth | |
700 | 1 | |a Horwitz, N. |4 oth | |
700 | 1 | |a Jain, V. |4 oth | |
700 | 1 | |a Lubrano, P. |4 oth | |
700 | 1 | |a Moneti, G.C. |4 oth | |
700 | 1 | |a Rozen, Y. |4 oth | |
700 | 1 | |a Rubin, P. |4 oth | |
700 | 1 | |a Shipsey, I.P. |4 oth | |
700 | 1 | |a Skwarnicki, T. |4 oth | |
700 | 1 | |a Sobolewski, Z. |4 oth | |
700 | 1 | |a Thulasidas, M. |4 oth | |
700 | 1 | |a Zhu, G.S. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods in Physics Research Section A: |d Amsterdam : Elsevier |g 320(1992), 1-2, Seite 114-127 |w (DE-627)NLEJ180854372 |w (DE-600)1466532-3 |x 0168-9002 |7 nnns |
773 | 1 | 8 | |g volume:320 |g year:1992 |g number:1-2 |g pages:114-127 |
856 | 4 | 0 | |u http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 320 |j 1992 |e 1-2 |h 114-127 |
matchkey_str |
article:01689002:1992----::moietfctodtcofrpyis |
---|---|
hierarchy_sort_str |
1992 |
publishDate |
1992 |
allfields |
(DE-627)NLEJ180949055 (DE-599)GBVNLZ180949055 DE-627 ger DE-627 rakwb eng A muon identification detector for B-physics near e^+e^- -> BB threshold 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bortoletto, D. oth Buda, L. oth Ennulat, J. oth Goldberg, M. oth Haupt, T. oth Holmes, R. oth Horwitz, N. oth Jain, V. oth Lubrano, P. oth Moneti, G.C. oth Rozen, Y. oth Rubin, P. oth Shipsey, I.P. oth Skwarnicki, T. oth Sobolewski, Z. oth Thulasidas, M. oth Zhu, G.S. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 320(1992), 1-2, Seite 114-127 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:320 year:1992 number:1-2 pages:114-127 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 320 1992 1-2 114-127 |
spelling |
(DE-627)NLEJ180949055 (DE-599)GBVNLZ180949055 DE-627 ger DE-627 rakwb eng A muon identification detector for B-physics near e^+e^- -> BB threshold 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bortoletto, D. oth Buda, L. oth Ennulat, J. oth Goldberg, M. oth Haupt, T. oth Holmes, R. oth Horwitz, N. oth Jain, V. oth Lubrano, P. oth Moneti, G.C. oth Rozen, Y. oth Rubin, P. oth Shipsey, I.P. oth Skwarnicki, T. oth Sobolewski, Z. oth Thulasidas, M. oth Zhu, G.S. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 320(1992), 1-2, Seite 114-127 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:320 year:1992 number:1-2 pages:114-127 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 320 1992 1-2 114-127 |
allfields_unstemmed |
(DE-627)NLEJ180949055 (DE-599)GBVNLZ180949055 DE-627 ger DE-627 rakwb eng A muon identification detector for B-physics near e^+e^- -> BB threshold 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bortoletto, D. oth Buda, L. oth Ennulat, J. oth Goldberg, M. oth Haupt, T. oth Holmes, R. oth Horwitz, N. oth Jain, V. oth Lubrano, P. oth Moneti, G.C. oth Rozen, Y. oth Rubin, P. oth Shipsey, I.P. oth Skwarnicki, T. oth Sobolewski, Z. oth Thulasidas, M. oth Zhu, G.S. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 320(1992), 1-2, Seite 114-127 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:320 year:1992 number:1-2 pages:114-127 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 320 1992 1-2 114-127 |
allfieldsGer |
(DE-627)NLEJ180949055 (DE-599)GBVNLZ180949055 DE-627 ger DE-627 rakwb eng A muon identification detector for B-physics near e^+e^- -> BB threshold 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bortoletto, D. oth Buda, L. oth Ennulat, J. oth Goldberg, M. oth Haupt, T. oth Holmes, R. oth Horwitz, N. oth Jain, V. oth Lubrano, P. oth Moneti, G.C. oth Rozen, Y. oth Rubin, P. oth Shipsey, I.P. oth Skwarnicki, T. oth Sobolewski, Z. oth Thulasidas, M. oth Zhu, G.S. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 320(1992), 1-2, Seite 114-127 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:320 year:1992 number:1-2 pages:114-127 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 320 1992 1-2 114-127 |
allfieldsSound |
(DE-627)NLEJ180949055 (DE-599)GBVNLZ180949055 DE-627 ger DE-627 rakwb eng A muon identification detector for B-physics near e^+e^- -> BB threshold 1992 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Bortoletto, D. oth Buda, L. oth Ennulat, J. oth Goldberg, M. oth Haupt, T. oth Holmes, R. oth Horwitz, N. oth Jain, V. oth Lubrano, P. oth Moneti, G.C. oth Rozen, Y. oth Rubin, P. oth Shipsey, I.P. oth Skwarnicki, T. oth Sobolewski, Z. oth Thulasidas, M. oth Zhu, G.S. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 320(1992), 1-2, Seite 114-127 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:320 year:1992 number:1-2 pages:114-127 http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 320 1992 1-2 114-127 |
language |
English |
source |
in Nuclear Instruments and Methods in Physics Research Section A: 320(1992), 1-2, Seite 114-127 volume:320 year:1992 number:1-2 pages:114-127 |
sourceStr |
in Nuclear Instruments and Methods in Physics Research Section A: 320(1992), 1-2, Seite 114-127 volume:320 year:1992 number:1-2 pages:114-127 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods in Physics Research Section A: |
authorswithroles_txt_mv |
Bortoletto, D. @@oth@@ Buda, L. @@oth@@ Ennulat, J. @@oth@@ Goldberg, M. @@oth@@ Haupt, T. @@oth@@ Holmes, R. @@oth@@ Horwitz, N. @@oth@@ Jain, V. @@oth@@ Lubrano, P. @@oth@@ Moneti, G.C. @@oth@@ Rozen, Y. @@oth@@ Rubin, P. @@oth@@ Shipsey, I.P. @@oth@@ Skwarnicki, T. @@oth@@ Sobolewski, Z. @@oth@@ Thulasidas, M. @@oth@@ Zhu, G.S. @@oth@@ |
publishDateDaySort_date |
1992-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ180854372 |
id |
NLEJ180949055 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180949055</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706141353.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1992 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180949055</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180949055</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A muon identification detector for B-physics near e^+e^- -> BB threshold</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1992</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bortoletto, D.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Buda, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ennulat, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Goldberg, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Haupt, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Holmes, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Horwitz, N.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Jain, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lubrano, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Moneti, G.C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rozen, Y.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rubin, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Shipsey, I.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Skwarnicki, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sobolewski, Z.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Thulasidas, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhu, G.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">320(1992), 1-2, Seite 114-127</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:320</subfield><subfield code="g">year:1992</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:114-127</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">320</subfield><subfield code="j">1992</subfield><subfield code="e">1-2</subfield><subfield code="h">114-127</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ180854372 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0168-9002 |
topic_title |
A muon identification detector for B-physics near e^+e^- -> BB threshold |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
d b db l b lb j e je m g mg t h th r h rh n h nh v j vj p l pl g m gm y r yr p r pr i s is t s ts z s zs m t mt g z gz |
hierarchy_parent_title |
Nuclear Instruments and Methods in Physics Research Section A: |
hierarchy_parent_id |
NLEJ180854372 |
hierarchy_top_title |
Nuclear Instruments and Methods in Physics Research Section A: |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ180854372 (DE-600)1466532-3 |
title |
A muon identification detector for B-physics near e^+e^- -> BB threshold |
spellingShingle |
A muon identification detector for B-physics near e^+e^- -> BB threshold |
ctrlnum |
(DE-627)NLEJ180949055 (DE-599)GBVNLZ180949055 |
title_full |
A muon identification detector for B-physics near e^+e^- -> BB threshold |
journal |
Nuclear Instruments and Methods in Physics Research Section A: |
journalStr |
Nuclear Instruments and Methods in Physics Research Section A: |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1992 |
contenttype_str_mv |
zzz |
container_start_page |
114 |
container_volume |
320 |
format_se |
Elektronische Aufsätze |
title_sort |
muon identification detector for b-physics near e^+e^- -> bb threshold |
title_auth |
A muon identification detector for B-physics near e^+e^- -> BB threshold |
abstract |
We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. |
abstractGer |
We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. |
abstract_unstemmed |
We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
1-2 |
title_short |
A muon identification detector for B-physics near e^+e^- -> BB threshold |
url |
http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U |
remote_bool |
true |
author2 |
Bortoletto, D. Buda, L. Ennulat, J. Goldberg, M. Haupt, T. Holmes, R. Horwitz, N. Jain, V. Lubrano, P. Moneti, G.C. Rozen, Y. Rubin, P. Shipsey, I.P. Skwarnicki, T. Sobolewski, Z. Thulasidas, M. Zhu, G.S. |
author2Str |
Bortoletto, D. Buda, L. Ennulat, J. Goldberg, M. Haupt, T. Holmes, R. Horwitz, N. Jain, V. Lubrano, P. Moneti, G.C. Rozen, Y. Rubin, P. Shipsey, I.P. Skwarnicki, T. Sobolewski, Z. Thulasidas, M. Zhu, G.S. |
ppnlink |
NLEJ180854372 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth |
up_date |
2024-07-06T05:01:56.288Z |
_version_ |
1803804597328805888 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ180949055</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706141353.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1992 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ180949055</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ180949055</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="2"><subfield code="a">A muon identification detector for B-physics near e^+e^- -> BB threshold</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1992</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">We describe the construction and performance of the muon identification system for the CLEO II detector at the Cornell Electron-positron Storage Ring (CESR). The system, based on plastic proportional tubes interleaved with an iron absorber, covers 0.85 of the total solid angle, has an identification efficiency between 0.89 and 0.99, depending on track penetration requirement, and a probability of misidentification about 0.007 for pions of 2.5 GeV and 0.030 for kaons of the same momentum.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bortoletto, D.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Buda, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Ennulat, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Goldberg, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Haupt, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Holmes, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Horwitz, N.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Jain, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lubrano, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Moneti, G.C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rozen, Y.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Rubin, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Shipsey, I.P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Skwarnicki, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Sobolewski, Z.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Thulasidas, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zhu, G.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">320(1992), 1-2, Seite 114-127</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:320</subfield><subfield code="g">year:1992</subfield><subfield code="g">number:1-2</subfield><subfield code="g">pages:114-127</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://linkinghub.elsevier.com/retrieve/pii/0168-9002(92)90771-U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">320</subfield><subfield code="j">1992</subfield><subfield code="e">1-2</subfield><subfield code="h">114-127</subfield></datafield></record></collection>
|
score |
7.400099 |