Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector
The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1994 |
---|
Reproduktion: |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
---|---|
Übergeordnetes Werk: |
in: Nuclear Instruments and Methods in Physics Research Section A: - Amsterdam : Elsevier, 344(1994), 1, Seite 216-219 |
Übergeordnetes Werk: |
volume:344 ; year:1994 ; number:1 ; pages:216-219 |
Links: |
---|
Katalog-ID: |
NLEJ181687305 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ181687305 | ||
003 | DE-627 | ||
005 | 20210706160812.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070505s1994 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ181687305 | ||
035 | |a (DE-599)GBVNLZ181687305 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
264 | 1 | |c 1994 | |
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. | ||
533 | |f Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 | ||
700 | 1 | |a Battiston, R. |4 oth | |
700 | 1 | |a Bertucci, B. |4 oth | |
700 | 1 | |a Bilei, G. |4 oth | |
700 | 1 | |a Checcucci, B. |4 oth | |
700 | 1 | |a Servoli, L. |4 oth | |
700 | 1 | |a Wang, S.J. |4 oth | |
700 | 1 | |a Passaleva, G. |4 oth | |
700 | 1 | |a Bay, A. |4 oth | |
700 | 1 | |a Burger, W.J. |4 oth | |
700 | 1 | |a Extermann, P. |4 oth | |
700 | 1 | |a Susinno, G. |4 oth | |
700 | 1 | |a Brooks, M. |4 oth | |
700 | 1 | |a Kapustinsky, J.S. |4 oth | |
700 | 1 | |a Kinnison, W.W. |4 oth | |
700 | 1 | |a Lee, D.M. |4 oth | |
700 | 1 | |a Mills, G.B. |4 oth | |
773 | 0 | 8 | |i in |t Nuclear Instruments and Methods in Physics Research Section A: |d Amsterdam : Elsevier |g 344(1994), 1, Seite 216-219 |w (DE-627)NLEJ180854372 |w (DE-600)1466532-3 |x 0168-9002 |7 nnns |
773 | 1 | 8 | |g volume:344 |g year:1994 |g number:1 |g pages:216-219 |
856 | 4 | 0 | |u http://dx.doi.org/10.1016/0168-9002(94)90673-4 |
912 | |a GBV_USEFLAG_H | ||
912 | |a ZDB-1-SDJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 344 |j 1994 |e 1 |h 216-219 |
matchkey_str |
article:01689002:1994----::xeineihhsxciiteosrcinfhlslc |
---|---|
hierarchy_sort_str |
1994 |
publishDate |
1994 |
allfields |
(DE-627)NLEJ181687305 (DE-599)GBVNLZ181687305 DE-627 ger DE-627 rakwb eng Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector 1994 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Battiston, R. oth Bertucci, B. oth Bilei, G. oth Checcucci, B. oth Servoli, L. oth Wang, S.J. oth Passaleva, G. oth Bay, A. oth Burger, W.J. oth Extermann, P. oth Susinno, G. oth Brooks, M. oth Kapustinsky, J.S. oth Kinnison, W.W. oth Lee, D.M. oth Mills, G.B. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 344(1994), 1, Seite 216-219 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:344 year:1994 number:1 pages:216-219 http://dx.doi.org/10.1016/0168-9002(94)90673-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 344 1994 1 216-219 |
spelling |
(DE-627)NLEJ181687305 (DE-599)GBVNLZ181687305 DE-627 ger DE-627 rakwb eng Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector 1994 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Battiston, R. oth Bertucci, B. oth Bilei, G. oth Checcucci, B. oth Servoli, L. oth Wang, S.J. oth Passaleva, G. oth Bay, A. oth Burger, W.J. oth Extermann, P. oth Susinno, G. oth Brooks, M. oth Kapustinsky, J.S. oth Kinnison, W.W. oth Lee, D.M. oth Mills, G.B. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 344(1994), 1, Seite 216-219 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:344 year:1994 number:1 pages:216-219 http://dx.doi.org/10.1016/0168-9002(94)90673-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 344 1994 1 216-219 |
allfields_unstemmed |
(DE-627)NLEJ181687305 (DE-599)GBVNLZ181687305 DE-627 ger DE-627 rakwb eng Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector 1994 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Battiston, R. oth Bertucci, B. oth Bilei, G. oth Checcucci, B. oth Servoli, L. oth Wang, S.J. oth Passaleva, G. oth Bay, A. oth Burger, W.J. oth Extermann, P. oth Susinno, G. oth Brooks, M. oth Kapustinsky, J.S. oth Kinnison, W.W. oth Lee, D.M. oth Mills, G.B. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 344(1994), 1, Seite 216-219 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:344 year:1994 number:1 pages:216-219 http://dx.doi.org/10.1016/0168-9002(94)90673-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 344 1994 1 216-219 |
allfieldsGer |
(DE-627)NLEJ181687305 (DE-599)GBVNLZ181687305 DE-627 ger DE-627 rakwb eng Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector 1994 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Battiston, R. oth Bertucci, B. oth Bilei, G. oth Checcucci, B. oth Servoli, L. oth Wang, S.J. oth Passaleva, G. oth Bay, A. oth Burger, W.J. oth Extermann, P. oth Susinno, G. oth Brooks, M. oth Kapustinsky, J.S. oth Kinnison, W.W. oth Lee, D.M. oth Mills, G.B. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 344(1994), 1, Seite 216-219 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:344 year:1994 number:1 pages:216-219 http://dx.doi.org/10.1016/0168-9002(94)90673-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 344 1994 1 216-219 |
allfieldsSound |
(DE-627)NLEJ181687305 (DE-599)GBVNLZ181687305 DE-627 ger DE-627 rakwb eng Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector 1994 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 Battiston, R. oth Bertucci, B. oth Bilei, G. oth Checcucci, B. oth Servoli, L. oth Wang, S.J. oth Passaleva, G. oth Bay, A. oth Burger, W.J. oth Extermann, P. oth Susinno, G. oth Brooks, M. oth Kapustinsky, J.S. oth Kinnison, W.W. oth Lee, D.M. oth Mills, G.B. oth in Nuclear Instruments and Methods in Physics Research Section A: Amsterdam : Elsevier 344(1994), 1, Seite 216-219 (DE-627)NLEJ180854372 (DE-600)1466532-3 0168-9002 nnns volume:344 year:1994 number:1 pages:216-219 http://dx.doi.org/10.1016/0168-9002(94)90673-4 GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE AR 344 1994 1 216-219 |
language |
English |
source |
in Nuclear Instruments and Methods in Physics Research Section A: 344(1994), 1, Seite 216-219 volume:344 year:1994 number:1 pages:216-219 |
sourceStr |
in Nuclear Instruments and Methods in Physics Research Section A: 344(1994), 1, Seite 216-219 volume:344 year:1994 number:1 pages:216-219 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Nuclear Instruments and Methods in Physics Research Section A: |
authorswithroles_txt_mv |
Battiston, R. @@oth@@ Bertucci, B. @@oth@@ Bilei, G. @@oth@@ Checcucci, B. @@oth@@ Servoli, L. @@oth@@ Wang, S.J. @@oth@@ Passaleva, G. @@oth@@ Bay, A. @@oth@@ Burger, W.J. @@oth@@ Extermann, P. @@oth@@ Susinno, G. @@oth@@ Brooks, M. @@oth@@ Kapustinsky, J.S. @@oth@@ Kinnison, W.W. @@oth@@ Lee, D.M. @@oth@@ Mills, G.B. @@oth@@ |
publishDateDaySort_date |
1994-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ180854372 |
id |
NLEJ181687305 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ181687305</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706160812.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1994 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ181687305</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ181687305</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1994</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Battiston, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bertucci, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bilei, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Checcucci, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Servoli, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wang, S.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Passaleva, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bay, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Burger, W.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Extermann, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Susinno, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Brooks, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kapustinsky, J.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kinnison, W.W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lee, D.M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mills, G.B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">344(1994), 1, Seite 216-219</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:344</subfield><subfield code="g">year:1994</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:216-219</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1016/0168-9002(94)90673-4</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">344</subfield><subfield code="j">1994</subfield><subfield code="e">1</subfield><subfield code="h">216-219</subfield></datafield></record></collection>
|
series2 |
Elsevier Journal Backfiles on ScienceDirect 1907 - 2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ180854372 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
0168-9002 |
topic_title |
Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
r b rb b b bb g b gb b c bc l s ls s w sw g p gp a b ab w b wb p e pe g s gs m b mb j k jk w k wk d l dl g m gm |
hierarchy_parent_title |
Nuclear Instruments and Methods in Physics Research Section A: |
hierarchy_parent_id |
NLEJ180854372 |
hierarchy_top_title |
Nuclear Instruments and Methods in Physics Research Section A: |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ180854372 (DE-600)1466532-3 |
title |
Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
spellingShingle |
Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
ctrlnum |
(DE-627)NLEJ181687305 (DE-599)GBVNLZ181687305 |
title_full |
Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
journal |
Nuclear Instruments and Methods in Physics Research Section A: |
journalStr |
Nuclear Instruments and Methods in Physics Research Section A: |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1994 |
contenttype_str_mv |
zzz |
container_start_page |
216 |
container_volume |
344 |
format_se |
Elektronische Aufsätze |
title_sort |
experience with the svx-h chip in the construction of the l3 silicon microvertex detector |
title_auth |
Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
abstract |
The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. |
abstractGer |
The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. |
abstract_unstemmed |
The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results. |
collection_details |
GBV_USEFLAG_H ZDB-1-SDJ GBV_NL_ARTICLE |
container_issue |
1 |
title_short |
Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector |
url |
http://dx.doi.org/10.1016/0168-9002(94)90673-4 |
remote_bool |
true |
author2 |
Battiston, R. Bertucci, B. Bilei, G. Checcucci, B. Servoli, L. Wang, S.J. Passaleva, G. Bay, A. Burger, W.J. Extermann, P. Susinno, G. Brooks, M. Kapustinsky, J.S. Kinnison, W.W. Lee, D.M. Mills, G.B. |
author2Str |
Battiston, R. Bertucci, B. Bilei, G. Checcucci, B. Servoli, L. Wang, S.J. Passaleva, G. Bay, A. Burger, W.J. Extermann, P. Susinno, G. Brooks, M. Kapustinsky, J.S. Kinnison, W.W. Lee, D.M. Mills, G.B. |
ppnlink |
NLEJ180854372 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth oth |
up_date |
2024-07-06T07:19:12.149Z |
_version_ |
1803813233257086976 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ181687305</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706160812.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070505s1994 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ181687305</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVNLZ181687305</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Experience with the SVX-H chip in the construction of the L3 Silicon Microvertex Detector</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1994</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The SVX is a charge preamplifier with a sample and hold stage and sparse readout capability developed at the Lawrence Berkeley Laboratory. The SVX radiation hard version has been used by the SMD collaboration to build the L3 Silicon Microvertex Detector where double-sided AC coupled silicon sensors are read out. The SVX-H test procedure in the SMD detector assembly phase will be described as well as the obtained results.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Elsevier Journal Backfiles on ScienceDirect 1907 - 2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Battiston, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bertucci, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bilei, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Checcucci, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Servoli, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Wang, S.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Passaleva, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bay, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Burger, W.J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Extermann, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Susinno, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Brooks, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kapustinsky, J.S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kinnison, W.W.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lee, D.M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Mills, G.B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Nuclear Instruments and Methods in Physics Research Section A:</subfield><subfield code="d">Amsterdam : Elsevier</subfield><subfield code="g">344(1994), 1, Seite 216-219</subfield><subfield code="w">(DE-627)NLEJ180854372</subfield><subfield code="w">(DE-600)1466532-3</subfield><subfield code="x">0168-9002</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:344</subfield><subfield code="g">year:1994</subfield><subfield code="g">number:1</subfield><subfield code="g">pages:216-219</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1016/0168-9002(94)90673-4</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_H</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SDJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">344</subfield><subfield code="j">1994</subfield><subfield code="e">1</subfield><subfield code="h">216-219</subfield></datafield></record></collection>
|
score |
7.401469 |