Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis
Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering cru...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1991 |
---|
Umfang: |
9 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
in: Journal of radioanalytical and nuclear chemistry - 1968, 154(1991) vom: Apr., Seite 255-263 |
Übergeordnetes Werk: |
volume:154 ; year:1991 ; month:04 ; pages:255-263 ; extent:9 |
Links: |
---|
Katalog-ID: |
NLEJ194903915 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ194903915 | ||
003 | DE-627 | ||
005 | 20230505185647.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070526s1991 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ194903915 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
264 | 1 | |c 1991 | |
300 | |a 9 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Bichler, M. |4 oth | |
773 | 0 | 8 | |i in |t Journal of radioanalytical and nuclear chemistry |d 1968 |g 154(1991) vom: Apr., Seite 255-263 |w (DE-627)NLEJ188994238 |w (DE-600)2017242-4 |x 1588-2780 |7 nnns |
773 | 1 | 8 | |g volume:154 |g year:1991 |g month:04 |g pages:255-263 |g extent:9 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/BF02165048 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 154 |j 1991 |c 4 |h 255-263 |g 9 |
matchkey_str |
article:15882780:1991----::eemntoomruynieasmlsymlynaiheprtrvltlztot |
---|---|
hierarchy_sort_str |
1991 |
publishDate |
1991 |
allfields |
(DE-627)NLEJ194903915 DE-627 ger DE-627 rakwb eng Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis 1991 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. Springer Online Journal Archives 1860-2002 Bichler, M. oth in Journal of radioanalytical and nuclear chemistry 1968 154(1991) vom: Apr., Seite 255-263 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:154 year:1991 month:04 pages:255-263 extent:9 http://dx.doi.org/10.1007/BF02165048 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 154 1991 4 255-263 9 |
spelling |
(DE-627)NLEJ194903915 DE-627 ger DE-627 rakwb eng Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis 1991 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. Springer Online Journal Archives 1860-2002 Bichler, M. oth in Journal of radioanalytical and nuclear chemistry 1968 154(1991) vom: Apr., Seite 255-263 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:154 year:1991 month:04 pages:255-263 extent:9 http://dx.doi.org/10.1007/BF02165048 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 154 1991 4 255-263 9 |
allfields_unstemmed |
(DE-627)NLEJ194903915 DE-627 ger DE-627 rakwb eng Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis 1991 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. Springer Online Journal Archives 1860-2002 Bichler, M. oth in Journal of radioanalytical and nuclear chemistry 1968 154(1991) vom: Apr., Seite 255-263 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:154 year:1991 month:04 pages:255-263 extent:9 http://dx.doi.org/10.1007/BF02165048 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 154 1991 4 255-263 9 |
allfieldsGer |
(DE-627)NLEJ194903915 DE-627 ger DE-627 rakwb eng Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis 1991 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. Springer Online Journal Archives 1860-2002 Bichler, M. oth in Journal of radioanalytical and nuclear chemistry 1968 154(1991) vom: Apr., Seite 255-263 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:154 year:1991 month:04 pages:255-263 extent:9 http://dx.doi.org/10.1007/BF02165048 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 154 1991 4 255-263 9 |
allfieldsSound |
(DE-627)NLEJ194903915 DE-627 ger DE-627 rakwb eng Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis 1991 9 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. Springer Online Journal Archives 1860-2002 Bichler, M. oth in Journal of radioanalytical and nuclear chemistry 1968 154(1991) vom: Apr., Seite 255-263 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:154 year:1991 month:04 pages:255-263 extent:9 http://dx.doi.org/10.1007/BF02165048 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 154 1991 4 255-263 9 |
language |
English |
source |
in Journal of radioanalytical and nuclear chemistry 154(1991) vom: Apr., Seite 255-263 volume:154 year:1991 month:04 pages:255-263 extent:9 |
sourceStr |
in Journal of radioanalytical and nuclear chemistry 154(1991) vom: Apr., Seite 255-263 volume:154 year:1991 month:04 pages:255-263 extent:9 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Journal of radioanalytical and nuclear chemistry |
authorswithroles_txt_mv |
Bichler, M. @@oth@@ |
publishDateDaySort_date |
1991-04-01T00:00:00Z |
hierarchy_top_id |
NLEJ188994238 |
id |
NLEJ194903915 |
language_de |
englisch |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ194903915</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230505185647.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070526s1991 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ194903915</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1991</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">9</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bichler, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Journal of radioanalytical and nuclear chemistry</subfield><subfield code="d">1968</subfield><subfield code="g">154(1991) vom: Apr., Seite 255-263</subfield><subfield code="w">(DE-627)NLEJ188994238</subfield><subfield code="w">(DE-600)2017242-4</subfield><subfield code="x">1588-2780</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:154</subfield><subfield code="g">year:1991</subfield><subfield code="g">month:04</subfield><subfield code="g">pages:255-263</subfield><subfield code="g">extent:9</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF02165048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">154</subfield><subfield code="j">1991</subfield><subfield code="c">4</subfield><subfield code="h">255-263</subfield><subfield code="g">9</subfield></datafield></record></collection>
|
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ194903915</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230505185647.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070526s1991 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ194903915</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1991</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">9</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bichler, M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Journal of radioanalytical and nuclear chemistry</subfield><subfield code="d">1968</subfield><subfield code="g">154(1991) vom: Apr., Seite 255-263</subfield><subfield code="w">(DE-627)NLEJ188994238</subfield><subfield code="w">(DE-600)2017242-4</subfield><subfield code="x">1588-2780</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:154</subfield><subfield code="g">year:1991</subfield><subfield code="g">month:04</subfield><subfield code="g">pages:255-263</subfield><subfield code="g">extent:9</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF02165048</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">154</subfield><subfield code="j">1991</subfield><subfield code="c">4</subfield><subfield code="h">255-263</subfield><subfield code="g">9</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ188994238 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1588-2780 |
topic_title |
Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
m b mb |
hierarchy_parent_title |
Journal of radioanalytical and nuclear chemistry |
hierarchy_parent_id |
NLEJ188994238 |
hierarchy_top_title |
Journal of radioanalytical and nuclear chemistry |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ188994238 (DE-600)2017242-4 |
title |
Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
spellingShingle |
Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
ctrlnum |
(DE-627)NLEJ194903915 |
title_full |
Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
journal |
Journal of radioanalytical and nuclear chemistry |
journalStr |
Journal of radioanalytical and nuclear chemistry |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1991 |
contenttype_str_mv |
zzz |
container_start_page |
255 |
container_volume |
154 |
physical |
9 |
format_se |
Elektronische Aufsätze |
title_sort |
determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
title_auth |
Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
abstract |
Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. |
abstractGer |
Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. |
abstract_unstemmed |
Abstract A high temperature volatilization technique was applied to lower the detection limit for the determination of mercury in mineral samples by neutron activation analysis to the 10–15 pg range. Activated charcoal was used to trap evaporated mercury. Geologic standard samples and weathering crusts from limestone buildings were analyzed. The data obtained indicate how the concentration of air pollutants varies. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
Determination of mercury in mineral samples by employing a high temperature volatilization technique and activation analysis |
url |
http://dx.doi.org/10.1007/BF02165048 |
remote_bool |
true |
author2 |
Bichler, M. |
author2Str |
Bichler, M. |
ppnlink |
NLEJ188994238 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth |
up_date |
2024-07-06T02:09:00.309Z |
_version_ |
1803793717326249984 |
score |
7.400401 |