Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask
Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiati...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1998 |
---|
Umfang: |
5 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
in: Journal of radioanalytical and nuclear chemistry - 1968, 234(1998) vom: Jan./Feb., Seite 37-41 |
Übergeordnetes Werk: |
volume:234 ; year:1998 ; month:01/02 ; pages:37-41 ; extent:5 |
Links: |
---|
Katalog-ID: |
NLEJ194941523 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ194941523 | ||
003 | DE-627 | ||
005 | 20230505194803.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070526s1998 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ194941523 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
264 | 1 | |c 1998 | |
300 | |a 5 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Angloher, G. |4 oth | |
700 | 1 | |a Goldbrunner, T. |4 oth | |
700 | 1 | |a Hentig, R. v. |4 oth | |
700 | 1 | |a Feilitzsch, F. v. |4 oth | |
773 | 0 | 8 | |i in |t Journal of radioanalytical and nuclear chemistry |d 1968 |g 234(1998) vom: Jan./Feb., Seite 37-41 |w (DE-627)NLEJ188994238 |w (DE-600)2017242-4 |x 1588-2780 |7 nnns |
773 | 1 | 8 | |g volume:234 |g year:1998 |g month:01/02 |g pages:37-41 |g extent:5 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/BF02389744 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 234 |j 1998 |c 1/2 |h 37-41 |g 5 |
matchkey_str |
article:15882780:1998----::etoatvtoaayioutaueaeia0mslcnige |
---|---|
hierarchy_sort_str |
1998 |
publishDate |
1998 |
allfields |
(DE-627)NLEJ194941523 DE-627 ger DE-627 rakwb eng Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask 1998 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. Springer Online Journal Archives 1860-2002 Angloher, G. oth Goldbrunner, T. oth Hentig, R. v. oth Feilitzsch, F. v. oth in Journal of radioanalytical and nuclear chemistry 1968 234(1998) vom: Jan./Feb., Seite 37-41 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:234 year:1998 month:01/02 pages:37-41 extent:5 http://dx.doi.org/10.1007/BF02389744 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 234 1998 1/2 37-41 5 |
spelling |
(DE-627)NLEJ194941523 DE-627 ger DE-627 rakwb eng Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask 1998 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. Springer Online Journal Archives 1860-2002 Angloher, G. oth Goldbrunner, T. oth Hentig, R. v. oth Feilitzsch, F. v. oth in Journal of radioanalytical and nuclear chemistry 1968 234(1998) vom: Jan./Feb., Seite 37-41 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:234 year:1998 month:01/02 pages:37-41 extent:5 http://dx.doi.org/10.1007/BF02389744 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 234 1998 1/2 37-41 5 |
allfields_unstemmed |
(DE-627)NLEJ194941523 DE-627 ger DE-627 rakwb eng Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask 1998 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. Springer Online Journal Archives 1860-2002 Angloher, G. oth Goldbrunner, T. oth Hentig, R. v. oth Feilitzsch, F. v. oth in Journal of radioanalytical and nuclear chemistry 1968 234(1998) vom: Jan./Feb., Seite 37-41 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:234 year:1998 month:01/02 pages:37-41 extent:5 http://dx.doi.org/10.1007/BF02389744 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 234 1998 1/2 37-41 5 |
allfieldsGer |
(DE-627)NLEJ194941523 DE-627 ger DE-627 rakwb eng Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask 1998 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. Springer Online Journal Archives 1860-2002 Angloher, G. oth Goldbrunner, T. oth Hentig, R. v. oth Feilitzsch, F. v. oth in Journal of radioanalytical and nuclear chemistry 1968 234(1998) vom: Jan./Feb., Seite 37-41 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:234 year:1998 month:01/02 pages:37-41 extent:5 http://dx.doi.org/10.1007/BF02389744 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 234 1998 1/2 37-41 5 |
allfieldsSound |
(DE-627)NLEJ194941523 DE-627 ger DE-627 rakwb eng Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask 1998 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. Springer Online Journal Archives 1860-2002 Angloher, G. oth Goldbrunner, T. oth Hentig, R. v. oth Feilitzsch, F. v. oth in Journal of radioanalytical and nuclear chemistry 1968 234(1998) vom: Jan./Feb., Seite 37-41 (DE-627)NLEJ188994238 (DE-600)2017242-4 1588-2780 nnns volume:234 year:1998 month:01/02 pages:37-41 extent:5 http://dx.doi.org/10.1007/BF02389744 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 234 1998 1/2 37-41 5 |
language |
English |
source |
in Journal of radioanalytical and nuclear chemistry 234(1998) vom: Jan./Feb., Seite 37-41 volume:234 year:1998 month:01/02 pages:37-41 extent:5 |
sourceStr |
in Journal of radioanalytical and nuclear chemistry 234(1998) vom: Jan./Feb., Seite 37-41 volume:234 year:1998 month:01/02 pages:37-41 extent:5 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Journal of radioanalytical and nuclear chemistry |
authorswithroles_txt_mv |
Angloher, G. @@oth@@ Goldbrunner, T. @@oth@@ Hentig, R. v. @@oth@@ Feilitzsch, F. v. @@oth@@ |
publishDateDaySort_date |
1998-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ188994238 |
id |
NLEJ194941523 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ194941523</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230505194803.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070526s1998 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ194941523</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1998</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">5</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Angloher, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Goldbrunner, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hentig, R. v.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Feilitzsch, F. v.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Journal of radioanalytical and nuclear chemistry</subfield><subfield code="d">1968</subfield><subfield code="g">234(1998) vom: Jan./Feb., Seite 37-41</subfield><subfield code="w">(DE-627)NLEJ188994238</subfield><subfield code="w">(DE-600)2017242-4</subfield><subfield code="x">1588-2780</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:234</subfield><subfield code="g">year:1998</subfield><subfield code="g">month:01/02</subfield><subfield code="g">pages:37-41</subfield><subfield code="g">extent:5</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF02389744</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">234</subfield><subfield code="j">1998</subfield><subfield code="c">1/2</subfield><subfield code="h">37-41</subfield><subfield code="g">5</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ188994238 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1588-2780 |
topic_title |
Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
g a ga t g tg r v h rv rvh f v f fv fvf |
hierarchy_parent_title |
Journal of radioanalytical and nuclear chemistry |
hierarchy_parent_id |
NLEJ188994238 |
hierarchy_top_title |
Journal of radioanalytical and nuclear chemistry |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ188994238 (DE-600)2017242-4 |
title |
Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
spellingShingle |
Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
ctrlnum |
(DE-627)NLEJ194941523 |
title_full |
Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
journal |
Journal of radioanalytical and nuclear chemistry |
journalStr |
Journal of radioanalytical and nuclear chemistry |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1998 |
contenttype_str_mv |
zzz |
container_start_page |
37 |
container_volume |
234 |
physical |
5 |
format_se |
Elektronische Aufsätze |
title_sort |
neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
title_auth |
Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
abstract |
Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. |
abstractGer |
Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. |
abstract_unstemmed |
Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask |
url |
http://dx.doi.org/10.1007/BF02389744 |
remote_bool |
true |
author2 |
Angloher, G. Goldbrunner, T. Hentig, R. v. Feilitzsch, F. v. |
author2Str |
Angloher, G. Goldbrunner, T. Hentig, R. v. Feilitzsch, F. v. |
ppnlink |
NLEJ188994238 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth |
up_date |
2024-07-06T02:16:27.507Z |
_version_ |
1803794186250485760 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ194941523</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230505194803.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070526s1998 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ194941523</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Neutron activation analysis of ultrapure water in a 500 ml silicon single crystal irradiation flask</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1998</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">5</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract Trace element analysis of ultrapure liquids requires the avoidance of contamination not only during preparation but also during irradiation of the sample. Double subboiling distilled water activated within flasks made out of synthetic quartz shows a significant correlation between irradiation time, quality of the flasks and the determined trace element concentration. The resulting falsification of the analysis and limitation of sensitivity seems to be caused by diffusion-like processes during irradiation. Even though single crystal FZ-silicon is rather brittle, it has been possible to fabricate a 500 ml irradiation flask out of this extremely pure material. The flask as well as its application in the analysis of double subboiling distilled water are discussed in the article.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Angloher, G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Goldbrunner, T.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hentig, R. v.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Feilitzsch, F. v.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Journal of radioanalytical and nuclear chemistry</subfield><subfield code="d">1968</subfield><subfield code="g">234(1998) vom: Jan./Feb., Seite 37-41</subfield><subfield code="w">(DE-627)NLEJ188994238</subfield><subfield code="w">(DE-600)2017242-4</subfield><subfield code="x">1588-2780</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:234</subfield><subfield code="g">year:1998</subfield><subfield code="g">month:01/02</subfield><subfield code="g">pages:37-41</subfield><subfield code="g">extent:5</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF02389744</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">234</subfield><subfield code="j">1998</subfield><subfield code="c">1/2</subfield><subfield code="h">37-41</subfield><subfield code="g">5</subfield></datafield></record></collection>
|
score |
7.4019375 |