Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging
Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1997 |
---|
Umfang: |
8 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
volume:24 ; year:1997 ; month:05 ; pages:530-537 ; extent:8 |
Links: |
---|
Katalog-ID: |
NLEJ202824225 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ202824225 | ||
003 | DE-627 | ||
005 | 20230506101238.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070528s1997 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ202824225 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
264 | 1 | |c 1997 | |
300 | |a 8 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Meeder, Joan G. |4 oth | |
700 | 1 | |a Blanksma, Paul K. |4 oth | |
700 | 1 | |a van der Wall, Ernst E. |4 oth | |
700 | 1 | |a Willemsen, Antoon T. M. |4 oth | |
700 | 1 | |a Pruim, Jan |4 oth | |
700 | 1 | |a Anthonio, Rutger L. |4 oth | |
700 | 1 | |a de Jong, Richard M. |4 oth | |
700 | 1 | |a Vaalburg, Willem |4 oth | |
700 | 1 | |a Lie, Kong I. |4 oth | |
773 | 1 | 8 | |g volume:24 |g year:1997 |g month:05 |g pages:530-537 |g extent:8 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/BF01267685 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 24 |j 1997 |c 5 |h 530-537 |g 8 |
matchkey_str |
meederjoangblanksmapaulkvanderwallernste:1997----:ooayaooinnainsihydoeeautowtpstoeisotmgahadaae |
---|---|
hierarchy_sort_str |
1997 |
publishDate |
1997 |
allfields |
(DE-627)NLEJ202824225 DE-627 ger DE-627 rakwb eng Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. Springer Online Journal Archives 1860-2002 Meeder, Joan G. oth Blanksma, Paul K. oth van der Wall, Ernst E. oth Willemsen, Antoon T. M. oth Pruim, Jan oth Anthonio, Rutger L. oth de Jong, Richard M. oth Vaalburg, Willem oth Lie, Kong I. oth volume:24 year:1997 month:05 pages:530-537 extent:8 http://dx.doi.org/10.1007/BF01267685 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 5 530-537 8 |
spelling |
(DE-627)NLEJ202824225 DE-627 ger DE-627 rakwb eng Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. Springer Online Journal Archives 1860-2002 Meeder, Joan G. oth Blanksma, Paul K. oth van der Wall, Ernst E. oth Willemsen, Antoon T. M. oth Pruim, Jan oth Anthonio, Rutger L. oth de Jong, Richard M. oth Vaalburg, Willem oth Lie, Kong I. oth volume:24 year:1997 month:05 pages:530-537 extent:8 http://dx.doi.org/10.1007/BF01267685 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 5 530-537 8 |
allfields_unstemmed |
(DE-627)NLEJ202824225 DE-627 ger DE-627 rakwb eng Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. Springer Online Journal Archives 1860-2002 Meeder, Joan G. oth Blanksma, Paul K. oth van der Wall, Ernst E. oth Willemsen, Antoon T. M. oth Pruim, Jan oth Anthonio, Rutger L. oth de Jong, Richard M. oth Vaalburg, Willem oth Lie, Kong I. oth volume:24 year:1997 month:05 pages:530-537 extent:8 http://dx.doi.org/10.1007/BF01267685 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 5 530-537 8 |
allfieldsGer |
(DE-627)NLEJ202824225 DE-627 ger DE-627 rakwb eng Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. Springer Online Journal Archives 1860-2002 Meeder, Joan G. oth Blanksma, Paul K. oth van der Wall, Ernst E. oth Willemsen, Antoon T. M. oth Pruim, Jan oth Anthonio, Rutger L. oth de Jong, Richard M. oth Vaalburg, Willem oth Lie, Kong I. oth volume:24 year:1997 month:05 pages:530-537 extent:8 http://dx.doi.org/10.1007/BF01267685 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 5 530-537 8 |
allfieldsSound |
(DE-627)NLEJ202824225 DE-627 ger DE-627 rakwb eng Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. Springer Online Journal Archives 1860-2002 Meeder, Joan G. oth Blanksma, Paul K. oth van der Wall, Ernst E. oth Willemsen, Antoon T. M. oth Pruim, Jan oth Anthonio, Rutger L. oth de Jong, Richard M. oth Vaalburg, Willem oth Lie, Kong I. oth volume:24 year:1997 month:05 pages:530-537 extent:8 http://dx.doi.org/10.1007/BF01267685 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 5 530-537 8 |
language |
English |
source |
volume:24 year:1997 month:05 pages:530-537 extent:8 |
sourceStr |
volume:24 year:1997 month:05 pages:530-537 extent:8 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
authorswithroles_txt_mv |
Meeder, Joan G. @@oth@@ Blanksma, Paul K. @@oth@@ van der Wall, Ernst E. @@oth@@ Willemsen, Antoon T. M. @@oth@@ Pruim, Jan @@oth@@ Anthonio, Rutger L. @@oth@@ de Jong, Richard M. @@oth@@ Vaalburg, Willem @@oth@@ Lie, Kong I. @@oth@@ |
publishDateDaySort_date |
1997-05-01T00:00:00Z |
id |
NLEJ202824225 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ202824225</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230506101238.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1997 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ202824225</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">8</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Meeder, Joan G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Blanksma, Paul K.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">van der Wall, Ernst E.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Willemsen, Antoon T. M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pruim, Jan</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Anthonio, Rutger L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">de Jong, Richard M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Vaalburg, Willem</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lie, Kong I.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:24</subfield><subfield code="g">year:1997</subfield><subfield code="g">month:05</subfield><subfield code="g">pages:530-537</subfield><subfield code="g">extent:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF01267685</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">24</subfield><subfield code="j">1997</subfield><subfield code="c">5</subfield><subfield code="h">530-537</subfield><subfield code="g">8</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
j g m jg jgm p k b pk pkb d w e e v dwee dweev a t m w atm atmw j p jp r l a rl rla j r m d jrm jrmd w v wv k i l ki kil |
isfreeaccess_txt |
false |
title |
Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
spellingShingle |
Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
ctrlnum |
(DE-627)NLEJ202824225 |
title_full |
Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1997 |
contenttype_str_mv |
zzz |
container_start_page |
530 |
container_volume |
24 |
physical |
8 |
format_se |
Elektronische Aufsätze |
title_sort |
coronary vasomotion in patients with syndrome x: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
title_auth |
Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
abstract |
Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. |
abstractGer |
Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. |
abstract_unstemmed |
Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging |
url |
http://dx.doi.org/10.1007/BF01267685 |
remote_bool |
true |
author2 |
Meeder, Joan G. Blanksma, Paul K. van der Wall, Ernst E. Willemsen, Antoon T. M. Pruim, Jan Anthonio, Rutger L. de Jong, Richard M. Vaalburg, Willem Lie, Kong I. |
author2Str |
Meeder, Joan G. Blanksma, Paul K. van der Wall, Ernst E. Willemsen, Antoon T. M. Pruim, Jan Anthonio, Rutger L. de Jong, Richard M. Vaalburg, Willem Lie, Kong I. |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth oth oth |
up_date |
2024-07-06T08:58:43.149Z |
_version_ |
1803819494303334400 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ202824225</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230506101238.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1997 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ202824225</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Coronary vasomotion in patients with syndrome X: evaluation with positron emission tomography and parametric myocardial perfusion imaging</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">8</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. The aim of this study was to elucidate further the causative mechanism of abnormal coronary vasomotion in patients with syndrome X. In patients with syndrome X, defined as angina pectoris and documented myocardial ischaemia during stress testing with normal findings at coronary angiography, abnormal coronary vasomotion of either the micro- or the macrocirculation has been suggested as the causative mechanism. Accordingly, we evaluated endothelial function, vasodilator reserve, and perfusion heterogeneity in these patients. Twenty-five patients with syndrome X (definitely normal coronary arteriogram, group A), 15 patients with minimal coronary artery disease (group B) and 21 healthy volunteers underwent [13N]ammonia positron emission tomography at rest, during cold pressor stimulation (endothelial function) and during dipyridamole stress testing (vasodilator reserve). Heterogeneity of myocardial perfusion was analysed by parametric polar mapping using a 480-segment model. In both patient groups, resting perfusion was increased compared to the normal subjects: group A, 127±31 ml·min−1·100 g−1; group B, 124±30 ml·min−1·100 g−1 normal subjects, 105±21 ml·min−1·100 g−1 (groups A and B vs normals, P<0.05). These differences were abolished after correction for rate-pressure product. During cold pressor stimulation, the perfusion responses (ratio of cold pressor perfusion to resting perfusion) were similar among the patients and the control subjects (group A, 1.20±0.23; group B, 1.24±0.22; normal subjects, 1.23±0.14). Likewise, during dipyridamole stress testing, perfusion responses were similar among the three groups (group A, 2.71±0.67; group B, 2.77±1.29; normal subjects, 2.91±1.04). In group A the heterogeneity of resting perfusion, expressed as coefficient of variation, was significantly different from the volunteers (20.1±4.5 vs 17.0±3.0, P<0.05). In group B (coefficient of variation 19.4±3.9) the difference from normal volunteers was not significant. In this study, patients with syndrome X and patients with minimal coronary artery disease showed normal perfusion responses during cold pressor stimulation and dipyridamole stress testing. Our findings therefore suggest that endothelial dysfunction and impaired vasodilator reserve are of no major pathophysiological relevance in patients with syndrome X. Rather, other mechanisms such as increased sympathetic tone and focal release of vasoactive substances may play a role in the pathogenesis of syndrome X.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Meeder, Joan G.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Blanksma, Paul K.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">van der Wall, Ernst E.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Willemsen, Antoon T. M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pruim, Jan</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Anthonio, Rutger L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">de Jong, Richard M.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Vaalburg, Willem</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lie, Kong I.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:24</subfield><subfield code="g">year:1997</subfield><subfield code="g">month:05</subfield><subfield code="g">pages:530-537</subfield><subfield code="g">extent:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF01267685</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">24</subfield><subfield code="j">1997</subfield><subfield code="c">5</subfield><subfield code="h">530-537</subfield><subfield code="g">8</subfield></datafield></record></collection>
|
score |
7.4006615 |