A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma
Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1997 |
---|
Umfang: |
8 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
volume:24 ; year:1997 ; month:06 ; pages:621-628 ; extent:8 |
Links: |
---|
Katalog-ID: |
NLEJ202824489 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ202824489 | ||
003 | DE-627 | ||
005 | 20230506101238.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070528s1997 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ202824489 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
264 | 1 | |c 1997 | |
300 | |a 8 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Kostakoglu, Lale |4 oth | |
700 | 1 | |a Uysal, Ug˘ur |4 oth | |
700 | 1 | |a Özyar, Enis |4 oth | |
700 | 1 | |a Demirkazik, Figen B. |4 oth | |
700 | 1 | |a Hayran, Mutlu |4 oth | |
700 | 1 | |a Atahan, Lale |4 oth | |
700 | 1 | |a Bekdik, Coxkun F. |4 oth | |
773 | 1 | 8 | |g volume:24 |g year:1997 |g month:06 |g pages:621-628 |g extent:8 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/BF00841399 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 24 |j 1997 |c 6 |h 621-628 |g 8 |
matchkey_str |
kostakoglulaleuysalugurzyarenisdemirkazi:1997----:cmaaietdotcntu9metmbadeheim9ttoomnigehtnoorpynhd |
---|---|
hierarchy_sort_str |
1997 |
publishDate |
1997 |
allfields |
(DE-627)NLEJ202824489 DE-627 ger DE-627 rakwb eng A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. Springer Online Journal Archives 1860-2002 Kostakoglu, Lale oth Uysal, Ug˘ur oth Özyar, Enis oth Demirkazik, Figen B. oth Hayran, Mutlu oth Atahan, Lale oth Bekdik, Coxkun F. oth volume:24 year:1997 month:06 pages:621-628 extent:8 http://dx.doi.org/10.1007/BF00841399 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 6 621-628 8 |
spelling |
(DE-627)NLEJ202824489 DE-627 ger DE-627 rakwb eng A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. Springer Online Journal Archives 1860-2002 Kostakoglu, Lale oth Uysal, Ug˘ur oth Özyar, Enis oth Demirkazik, Figen B. oth Hayran, Mutlu oth Atahan, Lale oth Bekdik, Coxkun F. oth volume:24 year:1997 month:06 pages:621-628 extent:8 http://dx.doi.org/10.1007/BF00841399 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 6 621-628 8 |
allfields_unstemmed |
(DE-627)NLEJ202824489 DE-627 ger DE-627 rakwb eng A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. Springer Online Journal Archives 1860-2002 Kostakoglu, Lale oth Uysal, Ug˘ur oth Özyar, Enis oth Demirkazik, Figen B. oth Hayran, Mutlu oth Atahan, Lale oth Bekdik, Coxkun F. oth volume:24 year:1997 month:06 pages:621-628 extent:8 http://dx.doi.org/10.1007/BF00841399 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 6 621-628 8 |
allfieldsGer |
(DE-627)NLEJ202824489 DE-627 ger DE-627 rakwb eng A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. Springer Online Journal Archives 1860-2002 Kostakoglu, Lale oth Uysal, Ug˘ur oth Özyar, Enis oth Demirkazik, Figen B. oth Hayran, Mutlu oth Atahan, Lale oth Bekdik, Coxkun F. oth volume:24 year:1997 month:06 pages:621-628 extent:8 http://dx.doi.org/10.1007/BF00841399 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 6 621-628 8 |
allfieldsSound |
(DE-627)NLEJ202824489 DE-627 ger DE-627 rakwb eng A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma 1997 8 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. Springer Online Journal Archives 1860-2002 Kostakoglu, Lale oth Uysal, Ug˘ur oth Özyar, Enis oth Demirkazik, Figen B. oth Hayran, Mutlu oth Atahan, Lale oth Bekdik, Coxkun F. oth volume:24 year:1997 month:06 pages:621-628 extent:8 http://dx.doi.org/10.1007/BF00841399 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 24 1997 6 621-628 8 |
language |
English |
source |
volume:24 year:1997 month:06 pages:621-628 extent:8 |
sourceStr |
volume:24 year:1997 month:06 pages:621-628 extent:8 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
authorswithroles_txt_mv |
Kostakoglu, Lale @@oth@@ Uysal, Ug˘ur @@oth@@ Özyar, Enis @@oth@@ Demirkazik, Figen B. @@oth@@ Hayran, Mutlu @@oth@@ Atahan, Lale @@oth@@ Bekdik, Coxkun F. @@oth@@ |
publishDateDaySort_date |
1997-06-01T00:00:00Z |
id |
NLEJ202824489 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ202824489</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230506101238.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1997 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ202824489</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">8</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kostakoglu, Lale</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Uysal, Ug˘ur</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Özyar, Enis</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Demirkazik, Figen B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hayran, Mutlu</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Atahan, Lale</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bekdik, Coxkun F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:24</subfield><subfield code="g">year:1997</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:621-628</subfield><subfield code="g">extent:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF00841399</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">24</subfield><subfield code="j">1997</subfield><subfield code="c">6</subfield><subfield code="h">621-628</subfield><subfield code="g">8</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
l k lk u u uu e ö eö f b d fb fbd m h mh l a la c f b cf cfb |
isfreeaccess_txt |
false |
title |
A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
spellingShingle |
A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
ctrlnum |
(DE-627)NLEJ202824489 |
title_full |
A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1997 |
contenttype_str_mv |
zzz |
container_start_page |
621 |
container_volume |
24 |
physical |
8 |
format_se |
Elektronische Aufsätze |
title_sort |
a comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
title_auth |
A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
abstract |
Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. |
abstractGer |
Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. |
abstract_unstemmed |
Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma |
url |
http://dx.doi.org/10.1007/BF00841399 |
remote_bool |
true |
author2 |
Kostakoglu, Lale Uysal, Ug˘ur Özyar, Enis Demirkazik, Figen B. Hayran, Mutlu Atahan, Lale Bekdik, Coxkun F. |
author2Str |
Kostakoglu, Lale Uysal, Ug˘ur Özyar, Enis Demirkazik, Figen B. Hayran, Mutlu Atahan, Lale Bekdik, Coxkun F. |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth oth |
up_date |
2024-07-06T08:58:46.960Z |
_version_ |
1803819498298408960 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ202824489</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230506101238.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1997 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ202824489</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">A comparative study of technetium-99m sestamibi and technetium-99m tetrofosmin single-photon tomography in the detection of nasopharyngeal carcinoma</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">8</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. The intention of this prospective study was to compare the diagnostic potential of technetium-99m sestamibi (MIBI) and a novel radiotracer, 99mTc-Tetrofosmin (Tetro), for the assessment of primary nasopharyngeal carcinoma (NPC) and the differentiation of residual disease from post-therapy changes. A total of 38 patients underwent MIBI and Tetro single-photon emission tomography (SPET) imaging at initial presentation (n=22) or following therapy (n=16). The findings were correlated with computed tomography or magnetic resonance imaging (MRI) on a site-by-site basis. Tumour/background (Tm/Bkg) ratios were obtained on coronal sections. Biopsy (nine patients) and/or 12- to 24-month clinical follow-up data were available in the post-therapy group. All primary disease sites were accurately detected by both imaging studies. Although there was no statistical difference between the two imaging techniques in the detection of primary disease, MIBI was superior to Tetro in the detection of regional lymph node metastases (sensitivity: 95% vs 79%). Tetro and MIBI SPET were true-positive in all patients (n=7) with proven residual/recurrent disease. In nine patients who had no evidence of residual/recurrent tumour, MRI was false-positive in five while Tetro and MIBI SPET were false-positive in two and three patients, respectively. Tm/Bkg ratios were ≤1.7 in all false-positive cases except one. Tetro, MIBI and MRI had specificities of 78%, 67% and 44%, and accuracies of 87.5%, 81% and 69%, respectively. The results of Tetro and of MIBI SPET were not statistically different from one another with regard to the prediction of residual/recurrent or metastatic NPC.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Kostakoglu, Lale</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Uysal, Ug˘ur</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Özyar, Enis</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Demirkazik, Figen B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hayran, Mutlu</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Atahan, Lale</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Bekdik, Coxkun F.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:24</subfield><subfield code="g">year:1997</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:621-628</subfield><subfield code="g">extent:8</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF00841399</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">24</subfield><subfield code="j">1997</subfield><subfield code="c">6</subfield><subfield code="h">621-628</subfield><subfield code="g">8</subfield></datafield></record></collection>
|
score |
7.402135 |