MR cholangiography: techniques and clinical applications
Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1998 |
---|
Umfang: |
10 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
in: European radiology - 1991, 8(1998) vom: Juni, Seite 901-910 |
Übergeordnetes Werk: |
volume:8 ; year:1998 ; month:06 ; pages:901-910 ; extent:10 |
Links: |
---|
Katalog-ID: |
NLEJ203196368 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ203196368 | ||
003 | DE-627 | ||
005 | 20210706121556.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070528s1998 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ203196368 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a MR cholangiography: techniques and clinical applications |
264 | 1 | |c 1998 | |
300 | |a 10 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Pavone, P. |4 oth | |
700 | 1 | |a Laghi, A. |4 oth | |
700 | 1 | |a Panebianco, V. |4 oth | |
700 | 1 | |a Catalano, C. |4 oth | |
700 | 1 | |a Lobina, L. |4 oth | |
700 | 1 | |a Passariello, R. |4 oth | |
773 | 0 | 8 | |i in |t European radiology |d 1991 |g 8(1998) vom: Juni, Seite 901-910 |w (DE-627)NLEJ188995870 |w (DE-600)1472718-3 |x 1432-1084 |7 nnns |
773 | 1 | 8 | |g volume:8 |g year:1998 |g month:06 |g pages:901-910 |g extent:10 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s003300050486 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 8 |j 1998 |c 6 |h 901-910 |g 10 |
matchkey_str |
article:14321084:1998----::rhlnigahtcnqeadlnc |
---|---|
hierarchy_sort_str |
1998 |
publishDate |
1998 |
allfields |
(DE-627)NLEJ203196368 DE-627 ger DE-627 rakwb eng MR cholangiography: techniques and clinical applications 1998 10 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. Springer Online Journal Archives 1860-2002 Pavone, P. oth Laghi, A. oth Panebianco, V. oth Catalano, C. oth Lobina, L. oth Passariello, R. oth in European radiology 1991 8(1998) vom: Juni, Seite 901-910 (DE-627)NLEJ188995870 (DE-600)1472718-3 1432-1084 nnns volume:8 year:1998 month:06 pages:901-910 extent:10 http://dx.doi.org/10.1007/s003300050486 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 8 1998 6 901-910 10 |
spelling |
(DE-627)NLEJ203196368 DE-627 ger DE-627 rakwb eng MR cholangiography: techniques and clinical applications 1998 10 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. Springer Online Journal Archives 1860-2002 Pavone, P. oth Laghi, A. oth Panebianco, V. oth Catalano, C. oth Lobina, L. oth Passariello, R. oth in European radiology 1991 8(1998) vom: Juni, Seite 901-910 (DE-627)NLEJ188995870 (DE-600)1472718-3 1432-1084 nnns volume:8 year:1998 month:06 pages:901-910 extent:10 http://dx.doi.org/10.1007/s003300050486 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 8 1998 6 901-910 10 |
allfields_unstemmed |
(DE-627)NLEJ203196368 DE-627 ger DE-627 rakwb eng MR cholangiography: techniques and clinical applications 1998 10 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. Springer Online Journal Archives 1860-2002 Pavone, P. oth Laghi, A. oth Panebianco, V. oth Catalano, C. oth Lobina, L. oth Passariello, R. oth in European radiology 1991 8(1998) vom: Juni, Seite 901-910 (DE-627)NLEJ188995870 (DE-600)1472718-3 1432-1084 nnns volume:8 year:1998 month:06 pages:901-910 extent:10 http://dx.doi.org/10.1007/s003300050486 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 8 1998 6 901-910 10 |
allfieldsGer |
(DE-627)NLEJ203196368 DE-627 ger DE-627 rakwb eng MR cholangiography: techniques and clinical applications 1998 10 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. Springer Online Journal Archives 1860-2002 Pavone, P. oth Laghi, A. oth Panebianco, V. oth Catalano, C. oth Lobina, L. oth Passariello, R. oth in European radiology 1991 8(1998) vom: Juni, Seite 901-910 (DE-627)NLEJ188995870 (DE-600)1472718-3 1432-1084 nnns volume:8 year:1998 month:06 pages:901-910 extent:10 http://dx.doi.org/10.1007/s003300050486 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 8 1998 6 901-910 10 |
allfieldsSound |
(DE-627)NLEJ203196368 DE-627 ger DE-627 rakwb eng MR cholangiography: techniques and clinical applications 1998 10 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. Springer Online Journal Archives 1860-2002 Pavone, P. oth Laghi, A. oth Panebianco, V. oth Catalano, C. oth Lobina, L. oth Passariello, R. oth in European radiology 1991 8(1998) vom: Juni, Seite 901-910 (DE-627)NLEJ188995870 (DE-600)1472718-3 1432-1084 nnns volume:8 year:1998 month:06 pages:901-910 extent:10 http://dx.doi.org/10.1007/s003300050486 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 8 1998 6 901-910 10 |
language |
English |
source |
in European radiology 8(1998) vom: Juni, Seite 901-910 volume:8 year:1998 month:06 pages:901-910 extent:10 |
sourceStr |
in European radiology 8(1998) vom: Juni, Seite 901-910 volume:8 year:1998 month:06 pages:901-910 extent:10 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
European radiology |
authorswithroles_txt_mv |
Pavone, P. @@oth@@ Laghi, A. @@oth@@ Panebianco, V. @@oth@@ Catalano, C. @@oth@@ Lobina, L. @@oth@@ Passariello, R. @@oth@@ |
publishDateDaySort_date |
1998-06-01T00:00:00Z |
hierarchy_top_id |
NLEJ188995870 |
id |
NLEJ203196368 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ203196368</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706121556.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1998 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ203196368</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">MR cholangiography: techniques and clinical applications</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1998</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">10</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pavone, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Laghi, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Panebianco, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Catalano, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lobina, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Passariello, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">European radiology</subfield><subfield code="d">1991</subfield><subfield code="g">8(1998) vom: Juni, Seite 901-910</subfield><subfield code="w">(DE-627)NLEJ188995870</subfield><subfield code="w">(DE-600)1472718-3</subfield><subfield code="x">1432-1084</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:8</subfield><subfield code="g">year:1998</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:901-910</subfield><subfield code="g">extent:10</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/s003300050486</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">8</subfield><subfield code="j">1998</subfield><subfield code="c">6</subfield><subfield code="h">901-910</subfield><subfield code="g">10</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ188995870 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1432-1084 |
topic_title |
MR cholangiography: techniques and clinical applications |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
p p pp a l al v p vp c c cc l l ll r p rp |
hierarchy_parent_title |
European radiology |
hierarchy_parent_id |
NLEJ188995870 |
hierarchy_top_title |
European radiology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ188995870 (DE-600)1472718-3 |
title |
MR cholangiography: techniques and clinical applications |
spellingShingle |
MR cholangiography: techniques and clinical applications |
ctrlnum |
(DE-627)NLEJ203196368 |
title_full |
MR cholangiography: techniques and clinical applications |
journal |
European radiology |
journalStr |
European radiology |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1998 |
contenttype_str_mv |
zzz |
container_start_page |
901 |
container_volume |
8 |
physical |
10 |
format_se |
Elektronische Aufsätze |
title_sort |
mr cholangiography: techniques and clinical applications |
title_auth |
MR cholangiography: techniques and clinical applications |
abstract |
Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. |
abstractGer |
Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. |
abstract_unstemmed |
Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
MR cholangiography: techniques and clinical applications |
url |
http://dx.doi.org/10.1007/s003300050486 |
remote_bool |
true |
author2 |
Pavone, P. Laghi, A. Panebianco, V. Catalano, C. Lobina, L. Passariello, R. |
author2Str |
Pavone, P. Laghi, A. Panebianco, V. Catalano, C. Lobina, L. Passariello, R. |
ppnlink |
NLEJ188995870 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth oth oth |
up_date |
2024-07-06T10:03:41.957Z |
_version_ |
1803823582500880384 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ203196368</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706121556.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1998 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ203196368</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">MR cholangiography: techniques and clinical applications</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1998</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">10</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. Magnetic resonance cholangiography (MRCP) is a new non-invasive imaging technique for the evaluation of bilio-pancreatic disorders. Different sequences, using both breathhold and non-breathhold techniques, have been employed in order to obtain MRCP images. The authors discuss the technical aspects, particularly focusing their attention on a non-breathhold, three-dimensional, fat-suppressed turbo-spin-echo sequence, optimized on a 0.5-T magnet with 15 mT/m gradients. Clinical applications of MRCP are evaluated, presenting data from both the literature and personal experience. The main indication for MRCP study is represented by the evaluation of common bile duct obstruction, with the aim of assessing the presence of the obstruction (accuracy 85–100 %) and, subsequently, its level (accuracy 91–100 %) and its cause. The utility of associating conventional MR images to MRCP in malignant strictures in order to characterize and stage the malignant lesions is also discussed. Finally, data are presented regarding the indications and utility of MR pancreatography in the evaluation of patients with chronic pancreatitis.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Pavone, P.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Laghi, A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Panebianco, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Catalano, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Lobina, L.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Passariello, R.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">European radiology</subfield><subfield code="d">1991</subfield><subfield code="g">8(1998) vom: Juni, Seite 901-910</subfield><subfield code="w">(DE-627)NLEJ188995870</subfield><subfield code="w">(DE-600)1472718-3</subfield><subfield code="x">1432-1084</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:8</subfield><subfield code="g">year:1998</subfield><subfield code="g">month:06</subfield><subfield code="g">pages:901-910</subfield><subfield code="g">extent:10</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/s003300050486</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">8</subfield><subfield code="j">1998</subfield><subfield code="c">6</subfield><subfield code="h">901-910</subfield><subfield code="g">10</subfield></datafield></record></collection>
|
score |
7.400728 |