Comparison of techniques for stationary coded aperture imaging in nuclear medicine
Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1982 |
---|
Umfang: |
5 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
in: Medical & biological engineering & computing - 2000, 20(1982) vom: Jan., Seite 7-11 |
Übergeordnetes Werk: |
volume:20 ; year:1982 ; month:01 ; pages:7-11 ; extent:5 |
Links: |
---|
Katalog-ID: |
NLEJ206722168 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ206722168 | ||
003 | DE-627 | ||
005 | 20230506094613.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070528s1982 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ206722168 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
264 | 1 | |c 1982 | |
300 | |a 5 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Fleming, J. S. |4 oth | |
700 | 1 | |a Goddard, B. A. |4 oth | |
773 | 0 | 8 | |i in |t Medical & biological engineering & computing |d 2000 |g 20(1982) vom: Jan., Seite 7-11 |w (DE-627)NLEJ188988025 |w (DE-600)2052667-2 |x 1741-0444 |7 nnns |
773 | 1 | 8 | |g volume:20 |g year:1982 |g month:01 |g pages:7-11 |g extent:5 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/BF02441843 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 20 |j 1982 |c 1 |h 7-11 |g 5 |
matchkey_str |
article:17410444:1982----::oprsnfehiusosainrcddpruemgn |
---|---|
hierarchy_sort_str |
1982 |
publishDate |
1982 |
allfields |
(DE-627)NLEJ206722168 DE-627 ger DE-627 rakwb eng Comparison of techniques for stationary coded aperture imaging in nuclear medicine 1982 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. Springer Online Journal Archives 1860-2002 Fleming, J. S. oth Goddard, B. A. oth in Medical & biological engineering & computing 2000 20(1982) vom: Jan., Seite 7-11 (DE-627)NLEJ188988025 (DE-600)2052667-2 1741-0444 nnns volume:20 year:1982 month:01 pages:7-11 extent:5 http://dx.doi.org/10.1007/BF02441843 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 20 1982 1 7-11 5 |
spelling |
(DE-627)NLEJ206722168 DE-627 ger DE-627 rakwb eng Comparison of techniques for stationary coded aperture imaging in nuclear medicine 1982 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. Springer Online Journal Archives 1860-2002 Fleming, J. S. oth Goddard, B. A. oth in Medical & biological engineering & computing 2000 20(1982) vom: Jan., Seite 7-11 (DE-627)NLEJ188988025 (DE-600)2052667-2 1741-0444 nnns volume:20 year:1982 month:01 pages:7-11 extent:5 http://dx.doi.org/10.1007/BF02441843 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 20 1982 1 7-11 5 |
allfields_unstemmed |
(DE-627)NLEJ206722168 DE-627 ger DE-627 rakwb eng Comparison of techniques for stationary coded aperture imaging in nuclear medicine 1982 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. Springer Online Journal Archives 1860-2002 Fleming, J. S. oth Goddard, B. A. oth in Medical & biological engineering & computing 2000 20(1982) vom: Jan., Seite 7-11 (DE-627)NLEJ188988025 (DE-600)2052667-2 1741-0444 nnns volume:20 year:1982 month:01 pages:7-11 extent:5 http://dx.doi.org/10.1007/BF02441843 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 20 1982 1 7-11 5 |
allfieldsGer |
(DE-627)NLEJ206722168 DE-627 ger DE-627 rakwb eng Comparison of techniques for stationary coded aperture imaging in nuclear medicine 1982 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. Springer Online Journal Archives 1860-2002 Fleming, J. S. oth Goddard, B. A. oth in Medical & biological engineering & computing 2000 20(1982) vom: Jan., Seite 7-11 (DE-627)NLEJ188988025 (DE-600)2052667-2 1741-0444 nnns volume:20 year:1982 month:01 pages:7-11 extent:5 http://dx.doi.org/10.1007/BF02441843 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 20 1982 1 7-11 5 |
allfieldsSound |
(DE-627)NLEJ206722168 DE-627 ger DE-627 rakwb eng Comparison of techniques for stationary coded aperture imaging in nuclear medicine 1982 5 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. Springer Online Journal Archives 1860-2002 Fleming, J. S. oth Goddard, B. A. oth in Medical & biological engineering & computing 2000 20(1982) vom: Jan., Seite 7-11 (DE-627)NLEJ188988025 (DE-600)2052667-2 1741-0444 nnns volume:20 year:1982 month:01 pages:7-11 extent:5 http://dx.doi.org/10.1007/BF02441843 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 20 1982 1 7-11 5 |
language |
English |
source |
in Medical & biological engineering & computing 20(1982) vom: Jan., Seite 7-11 volume:20 year:1982 month:01 pages:7-11 extent:5 |
sourceStr |
in Medical & biological engineering & computing 20(1982) vom: Jan., Seite 7-11 volume:20 year:1982 month:01 pages:7-11 extent:5 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
container_title |
Medical & biological engineering & computing |
authorswithroles_txt_mv |
Fleming, J. S. @@oth@@ Goddard, B. A. @@oth@@ |
publishDateDaySort_date |
1982-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ188988025 |
id |
NLEJ206722168 |
language_de |
englisch |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ206722168</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230506094613.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1982 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ206722168</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Comparison of techniques for stationary coded aperture imaging in nuclear medicine</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1982</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">5</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Fleming, J. S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Goddard, B. A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Medical & biological engineering & computing</subfield><subfield code="d">2000</subfield><subfield code="g">20(1982) vom: Jan., Seite 7-11</subfield><subfield code="w">(DE-627)NLEJ188988025</subfield><subfield code="w">(DE-600)2052667-2</subfield><subfield code="x">1741-0444</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:20</subfield><subfield code="g">year:1982</subfield><subfield code="g">month:01</subfield><subfield code="g">pages:7-11</subfield><subfield code="g">extent:5</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF02441843</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">20</subfield><subfield code="j">1982</subfield><subfield code="c">1</subfield><subfield code="h">7-11</subfield><subfield code="g">5</subfield></datafield></record></collection>
|
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ206722168</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230506094613.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1982 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ206722168</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Comparison of techniques for stationary coded aperture imaging in nuclear medicine</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1982</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">5</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Fleming, J. S.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Goddard, B. A.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">in</subfield><subfield code="t">Medical & biological engineering & computing</subfield><subfield code="d">2000</subfield><subfield code="g">20(1982) vom: Jan., Seite 7-11</subfield><subfield code="w">(DE-627)NLEJ188988025</subfield><subfield code="w">(DE-600)2052667-2</subfield><subfield code="x">1741-0444</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:20</subfield><subfield code="g">year:1982</subfield><subfield code="g">month:01</subfield><subfield code="g">pages:7-11</subfield><subfield code="g">extent:5</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/BF02441843</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">20</subfield><subfield code="j">1982</subfield><subfield code="c">1</subfield><subfield code="h">7-11</subfield><subfield code="g">5</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ188988025 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1741-0444 |
topic_title |
Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
j s f js jsf b a g ba bag |
hierarchy_parent_title |
Medical & biological engineering & computing |
hierarchy_parent_id |
NLEJ188988025 |
hierarchy_top_title |
Medical & biological engineering & computing |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ188988025 (DE-600)2052667-2 |
title |
Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
spellingShingle |
Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
ctrlnum |
(DE-627)NLEJ206722168 |
title_full |
Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
journal |
Medical & biological engineering & computing |
journalStr |
Medical & biological engineering & computing |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1982 |
contenttype_str_mv |
zzz |
container_start_page |
7 |
container_volume |
20 |
physical |
5 |
format_se |
Elektronische Aufsätze |
title_sort |
comparison of techniques for stationary coded aperture imaging in nuclear medicine |
title_auth |
Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
abstract |
Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. |
abstractGer |
Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. |
abstract_unstemmed |
Abstract The relative merits of different available coded aperture techniques are considered with reference to their applicability to nuclear medicine radionuclide imaging. The theory and practical implementation using gamma camera and computer system of two such methods deconvolution and arithmetic reconstruction technique are described. Some initial results are presented and the implications discussed. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
Comparison of techniques for stationary coded aperture imaging in nuclear medicine |
url |
http://dx.doi.org/10.1007/BF02441843 |
remote_bool |
true |
author2 |
Fleming, J. S. Goddard, B. A. |
author2Str |
Fleming, J. S. Goddard, B. A. |
ppnlink |
NLEJ188988025 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
up_date |
2024-07-06T07:42:24.485Z |
_version_ |
1803814693227200512 |
score |
7.3995256 |