Systems and instruments for laparoscopic surgery without pneumoperitoneum
Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored...
Ausführliche Beschreibung
Autor*in: |
---|
Format: |
E-Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
1997 |
---|
Umfang: |
7 |
---|
Reproduktion: |
Springer Online Journal Archives 1860-2002 |
---|---|
Übergeordnetes Werk: |
volume:11 ; year:1997 ; month:08 ; pages:868 -874 ; extent:7 |
Links: |
---|
Katalog-ID: |
NLEJ207440158 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ207440158 | ||
003 | DE-627 | ||
005 | 20210706230442.0 | ||
007 | cr uuu---uuuuu | ||
008 | 070528s1997 xx |||||o 00| ||eng c | ||
035 | |a (DE-627)NLEJ207440158 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
245 | 1 | 0 | |a Systems and instruments for laparoscopic surgery without pneumoperitoneum |
264 | 1 | |c 1997 | |
300 | |a 7 | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. | ||
533 | |f Springer Online Journal Archives 1860-2002 | ||
700 | 1 | |a Gutt, C. N. |4 oth | |
700 | 1 | |a Daume, J. |4 oth | |
700 | 1 | |a Schaeff, B. |4 oth | |
700 | 1 | |a Paolucci, V. |4 oth | |
773 | 1 | 8 | |g volume:11 |g year:1997 |g month:08 |g pages:868 -874 |g extent:7 |
856 | 4 | 0 | |u http://dx.doi.org/10.1007/s004649900474 |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-SOJ | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 11 |j 1997 |c 8 |h 868 -874 |g 7 |
matchkey_str |
guttcndaumejschaeffbpaolucciv:1997----:ytmadntuetfraaocpcugrwto |
---|---|
hierarchy_sort_str |
1997 |
publishDate |
1997 |
allfields |
(DE-627)NLEJ207440158 DE-627 ger DE-627 rakwb eng Systems and instruments for laparoscopic surgery without pneumoperitoneum 1997 7 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. Springer Online Journal Archives 1860-2002 Gutt, C. N. oth Daume, J. oth Schaeff, B. oth Paolucci, V. oth volume:11 year:1997 month:08 pages:868 -874 extent:7 http://dx.doi.org/10.1007/s004649900474 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 11 1997 8 868 -874 7 |
spelling |
(DE-627)NLEJ207440158 DE-627 ger DE-627 rakwb eng Systems and instruments for laparoscopic surgery without pneumoperitoneum 1997 7 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. Springer Online Journal Archives 1860-2002 Gutt, C. N. oth Daume, J. oth Schaeff, B. oth Paolucci, V. oth volume:11 year:1997 month:08 pages:868 -874 extent:7 http://dx.doi.org/10.1007/s004649900474 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 11 1997 8 868 -874 7 |
allfields_unstemmed |
(DE-627)NLEJ207440158 DE-627 ger DE-627 rakwb eng Systems and instruments for laparoscopic surgery without pneumoperitoneum 1997 7 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. Springer Online Journal Archives 1860-2002 Gutt, C. N. oth Daume, J. oth Schaeff, B. oth Paolucci, V. oth volume:11 year:1997 month:08 pages:868 -874 extent:7 http://dx.doi.org/10.1007/s004649900474 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 11 1997 8 868 -874 7 |
allfieldsGer |
(DE-627)NLEJ207440158 DE-627 ger DE-627 rakwb eng Systems and instruments for laparoscopic surgery without pneumoperitoneum 1997 7 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. Springer Online Journal Archives 1860-2002 Gutt, C. N. oth Daume, J. oth Schaeff, B. oth Paolucci, V. oth volume:11 year:1997 month:08 pages:868 -874 extent:7 http://dx.doi.org/10.1007/s004649900474 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 11 1997 8 868 -874 7 |
allfieldsSound |
(DE-627)NLEJ207440158 DE-627 ger DE-627 rakwb eng Systems and instruments for laparoscopic surgery without pneumoperitoneum 1997 7 nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. Springer Online Journal Archives 1860-2002 Gutt, C. N. oth Daume, J. oth Schaeff, B. oth Paolucci, V. oth volume:11 year:1997 month:08 pages:868 -874 extent:7 http://dx.doi.org/10.1007/s004649900474 GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE AR 11 1997 8 868 -874 7 |
language |
English |
source |
volume:11 year:1997 month:08 pages:868 -874 extent:7 |
sourceStr |
volume:11 year:1997 month:08 pages:868 -874 extent:7 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
isfreeaccess_bool |
false |
authorswithroles_txt_mv |
Gutt, C. N. @@oth@@ Daume, J. @@oth@@ Schaeff, B. @@oth@@ Paolucci, V. @@oth@@ |
publishDateDaySort_date |
1997-08-01T00:00:00Z |
id |
NLEJ207440158 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ207440158</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706230442.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1997 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ207440158</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Systems and instruments for laparoscopic surgery without pneumoperitoneum</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">7</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gutt, C. N.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Daume, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schaeff, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Paolucci, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:11</subfield><subfield code="g">year:1997</subfield><subfield code="g">month:08</subfield><subfield code="g">pages:868 -874</subfield><subfield code="g">extent:7</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/s004649900474</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">11</subfield><subfield code="j">1997</subfield><subfield code="c">8</subfield><subfield code="h">868 -874</subfield><subfield code="g">7</subfield></datafield></record></collection>
|
series2 |
Springer Online Journal Archives 1860-2002 |
format |
electronic Article |
delete_txt_mv |
keep |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
topic_title |
Systems and instruments for laparoscopic surgery without pneumoperitoneum |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
c n g cn cng j d jd b s bs v p vp |
isfreeaccess_txt |
false |
title |
Systems and instruments for laparoscopic surgery without pneumoperitoneum |
spellingShingle |
Systems and instruments for laparoscopic surgery without pneumoperitoneum |
ctrlnum |
(DE-627)NLEJ207440158 |
title_full |
Systems and instruments for laparoscopic surgery without pneumoperitoneum |
lang_code |
eng |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1997 |
contenttype_str_mv |
zzz |
container_start_page |
868 |
container_volume |
11 |
physical |
7 |
format_se |
Elektronische Aufsätze |
title_sort |
systems and instruments for laparoscopic surgery without pneumoperitoneum |
title_auth |
Systems and instruments for laparoscopic surgery without pneumoperitoneum |
abstract |
Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. |
abstractGer |
Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. |
abstract_unstemmed |
Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae. |
collection_details |
GBV_USEFLAG_U ZDB-1-SOJ GBV_NL_ARTICLE |
title_short |
Systems and instruments for laparoscopic surgery without pneumoperitoneum |
url |
http://dx.doi.org/10.1007/s004649900474 |
remote_bool |
true |
author2 |
Gutt, C. N. Daume, J. Schaeff, B. Paolucci, V. |
author2Str |
Gutt, C. N. Daume, J. Schaeff, B. Paolucci, V. |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth oth |
up_date |
2024-07-06T09:41:10.079Z |
_version_ |
1803822164954054656 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ207440158</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210706230442.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">070528s1997 xx |||||o 00| ||eng c</controlfield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ207440158</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Systems and instruments for laparoscopic surgery without pneumoperitoneum</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">1997</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">7</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract. The insufflation of carbon dioxide into the peritoneal cavity is a routine technique of abdominal exposure in laparoscopic surgery. Because of adverse physiological effects and technical disadvantages of the pneumoperitoneum, alternative methods of abdominal wall lifting have been explored recently. Two groups of retraction systems exist: intraabdominal lifting and subcutaneous lifting of the abdominal wall. Some systems require additional pneumoperitoneum, because the extent of intraabdominal exposure is not sufficient. Other systems are working completely without gas insufflation. Two systems combine abdominal wall lifting with pressure on the internal organs. Every method allows the use of standard laparoscopic instruments, which originally were designed for a regular pneumoperitoneum. The use of a low-pressure pneumoperitoneum in combination with mechanical augmentation of the peritoneal cavity reduces physiological disadvantages of laparoscopy. But technical advantages, such as combination of laparoscopic and open techniques, can be realized only without gas insufflation. Conventional instruments have been designed to fit the ergonomical needs of isopneumic laparoscopy and to be employed with simple valveless cannulae.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Springer Online Journal Archives 1860-2002</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gutt, C. N.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Daume, J.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schaeff, B.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Paolucci, V.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:11</subfield><subfield code="g">year:1997</subfield><subfield code="g">month:08</subfield><subfield code="g">pages:868 -874</subfield><subfield code="g">extent:7</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1007/s004649900474</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-SOJ</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">11</subfield><subfield code="j">1997</subfield><subfield code="c">8</subfield><subfield code="h">868 -874</subfield><subfield code="g">7</subfield></datafield></record></collection>
|
score |
7.402936 |