Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate
summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization...
Ausführliche Beschreibung
Autor*in: |
Takahashi, Y. [verfasserIn] Itoh, K. [verfasserIn] Manabe, A. [verfasserIn] |
---|
Format: |
E-Artikel |
---|
Erschienen: |
Oxford, UK: Blackwell Science Ltd ; 2004 |
---|
Schlagwörter: |
---|
Umfang: |
Online-Ressource |
---|
Reproduktion: |
2004 ; Blackwell Publishing Journal Backfiles 1879-2005 |
---|---|
Übergeordnetes Werk: |
In: Journal of oral rehabilitation - Oxford [u.a.] : Wiley-Blackwell, 1974, 31(2004), 12, Seite 0 |
Übergeordnetes Werk: |
volume:31 ; year:2004 ; number:12 ; pages:0 |
Links: |
---|
DOI / URN: |
10.1111/j.1365-2842.2004.01362.x |
---|
Katalog-ID: |
NLEJ243044291 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ243044291 | ||
003 | DE-627 | ||
005 | 20210707171724.0 | ||
007 | cr uuu---uuuuu | ||
008 | 120427s2004 xx |||||o 00| ||und c | ||
024 | 7 | |a 10.1111/j.1365-2842.2004.01362.x |2 doi | |
035 | |a (DE-627)NLEJ243044291 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
100 | 1 | |a Takahashi, Y. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
264 | 1 | |a Oxford, UK |b Blackwell Science Ltd |c 2004 | |
300 | |a Online-Ressource | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. | ||
533 | |d 2004 |f Blackwell Publishing Journal Backfiles 1879-2005 |7 |2004|||||||||| | ||
650 | 4 | |a 2-hydroxyethyl methacrylate | |
700 | 1 | |a Itoh, K. |e verfasserin |4 aut | |
700 | 1 | |a Manabe, A. |e verfasserin |4 aut | |
700 | 1 | |a Tani, C. |4 oth | |
700 | 1 | |a Hisamitsu, H. |4 oth | |
773 | 0 | 8 | |i In |t Journal of oral rehabilitation |d Oxford [u.a.] : Wiley-Blackwell, 1974 |g 31(2004), 12, Seite 0 |h Online-Ressource |w (DE-627)NLEJ243927177 |w (DE-600)2007587-X |x 1365-2842 |7 nnns |
773 | 1 | 8 | |g volume:31 |g year:2004 |g number:12 |g pages:0 |
856 | 4 | 0 | |u http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x |q text/html |x Verlag |z Deutschlandweit zugänglich |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-DJB | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 31 |j 2004 |e 12 |h 0 |
author_variant |
y t yt k i ki a m am |
---|---|
matchkey_str |
article:13652842:2004----::odnefccadiefetoteihuiylcr |
hierarchy_sort_str |
2004 |
publishDate |
2004 |
allfields |
10.1111/j.1365-2842.2004.01362.x doi (DE-627)NLEJ243044291 DE-627 ger DE-627 rakwb Takahashi, Y. verfasserin aut Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate Oxford, UK Blackwell Science Ltd 2004 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. 2004 Blackwell Publishing Journal Backfiles 1879-2005 |2004|||||||||| 2-hydroxyethyl methacrylate Itoh, K. verfasserin aut Manabe, A. verfasserin aut Tani, C. oth Hisamitsu, H. oth In Journal of oral rehabilitation Oxford [u.a.] : Wiley-Blackwell, 1974 31(2004), 12, Seite 0 Online-Ressource (DE-627)NLEJ243927177 (DE-600)2007587-X 1365-2842 nnns volume:31 year:2004 number:12 pages:0 http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 31 2004 12 0 |
spelling |
10.1111/j.1365-2842.2004.01362.x doi (DE-627)NLEJ243044291 DE-627 ger DE-627 rakwb Takahashi, Y. verfasserin aut Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate Oxford, UK Blackwell Science Ltd 2004 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. 2004 Blackwell Publishing Journal Backfiles 1879-2005 |2004|||||||||| 2-hydroxyethyl methacrylate Itoh, K. verfasserin aut Manabe, A. verfasserin aut Tani, C. oth Hisamitsu, H. oth In Journal of oral rehabilitation Oxford [u.a.] : Wiley-Blackwell, 1974 31(2004), 12, Seite 0 Online-Ressource (DE-627)NLEJ243927177 (DE-600)2007587-X 1365-2842 nnns volume:31 year:2004 number:12 pages:0 http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 31 2004 12 0 |
allfields_unstemmed |
10.1111/j.1365-2842.2004.01362.x doi (DE-627)NLEJ243044291 DE-627 ger DE-627 rakwb Takahashi, Y. verfasserin aut Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate Oxford, UK Blackwell Science Ltd 2004 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. 2004 Blackwell Publishing Journal Backfiles 1879-2005 |2004|||||||||| 2-hydroxyethyl methacrylate Itoh, K. verfasserin aut Manabe, A. verfasserin aut Tani, C. oth Hisamitsu, H. oth In Journal of oral rehabilitation Oxford [u.a.] : Wiley-Blackwell, 1974 31(2004), 12, Seite 0 Online-Ressource (DE-627)NLEJ243927177 (DE-600)2007587-X 1365-2842 nnns volume:31 year:2004 number:12 pages:0 http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 31 2004 12 0 |
allfieldsGer |
10.1111/j.1365-2842.2004.01362.x doi (DE-627)NLEJ243044291 DE-627 ger DE-627 rakwb Takahashi, Y. verfasserin aut Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate Oxford, UK Blackwell Science Ltd 2004 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. 2004 Blackwell Publishing Journal Backfiles 1879-2005 |2004|||||||||| 2-hydroxyethyl methacrylate Itoh, K. verfasserin aut Manabe, A. verfasserin aut Tani, C. oth Hisamitsu, H. oth In Journal of oral rehabilitation Oxford [u.a.] : Wiley-Blackwell, 1974 31(2004), 12, Seite 0 Online-Ressource (DE-627)NLEJ243927177 (DE-600)2007587-X 1365-2842 nnns volume:31 year:2004 number:12 pages:0 http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 31 2004 12 0 |
allfieldsSound |
10.1111/j.1365-2842.2004.01362.x doi (DE-627)NLEJ243044291 DE-627 ger DE-627 rakwb Takahashi, Y. verfasserin aut Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate Oxford, UK Blackwell Science Ltd 2004 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. 2004 Blackwell Publishing Journal Backfiles 1879-2005 |2004|||||||||| 2-hydroxyethyl methacrylate Itoh, K. verfasserin aut Manabe, A. verfasserin aut Tani, C. oth Hisamitsu, H. oth In Journal of oral rehabilitation Oxford [u.a.] : Wiley-Blackwell, 1974 31(2004), 12, Seite 0 Online-Ressource (DE-627)NLEJ243927177 (DE-600)2007587-X 1365-2842 nnns volume:31 year:2004 number:12 pages:0 http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 31 2004 12 0 |
source |
In Journal of oral rehabilitation 31(2004), 12, Seite 0 volume:31 year:2004 number:12 pages:0 |
sourceStr |
In Journal of oral rehabilitation 31(2004), 12, Seite 0 volume:31 year:2004 number:12 pages:0 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
2-hydroxyethyl methacrylate |
isfreeaccess_bool |
false |
container_title |
Journal of oral rehabilitation |
authorswithroles_txt_mv |
Takahashi, Y. @@aut@@ Itoh, K. @@aut@@ Manabe, A. @@aut@@ Tani, C. @@oth@@ Hisamitsu, H. @@oth@@ |
publishDateDaySort_date |
2004-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ243927177 |
id |
NLEJ243044291 |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ243044291</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210707171724.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">120427s2004 xx |||||o 00| ||und c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1111/j.1365-2842.2004.01362.x</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ243044291</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Takahashi, Y.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Oxford, UK</subfield><subfield code="b">Blackwell Science Ltd</subfield><subfield code="c">2004</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="d">2004</subfield><subfield code="f">Blackwell Publishing Journal Backfiles 1879-2005</subfield><subfield code="7">|2004||||||||||</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">2-hydroxyethyl methacrylate</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Itoh, K.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Manabe, A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tani, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hisamitsu, H.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Journal of oral rehabilitation</subfield><subfield code="d">Oxford [u.a.] : Wiley-Blackwell, 1974</subfield><subfield code="g">31(2004), 12, Seite 0</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)NLEJ243927177</subfield><subfield code="w">(DE-600)2007587-X</subfield><subfield code="x">1365-2842</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:31</subfield><subfield code="g">year:2004</subfield><subfield code="g">number:12</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x</subfield><subfield code="q">text/html</subfield><subfield code="x">Verlag</subfield><subfield code="z">Deutschlandweit zugänglich</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-DJB</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">31</subfield><subfield code="j">2004</subfield><subfield code="e">12</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
series2 |
Blackwell Publishing Journal Backfiles 1879-2005 |
author |
Takahashi, Y. |
spellingShingle |
Takahashi, Y. misc 2-hydroxyethyl methacrylate Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
authorStr |
Takahashi, Y. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ243927177 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut |
collection |
NL |
publishPlace |
Oxford, UK |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1365-2842 |
topic_title |
Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate 2-hydroxyethyl methacrylate |
publisher |
Blackwell Science Ltd |
publisherStr |
Blackwell Science Ltd |
topic |
misc 2-hydroxyethyl methacrylate |
topic_unstemmed |
misc 2-hydroxyethyl methacrylate |
topic_browse |
misc 2-hydroxyethyl methacrylate |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
c t ct h h hh |
hierarchy_parent_title |
Journal of oral rehabilitation |
hierarchy_parent_id |
NLEJ243927177 |
hierarchy_top_title |
Journal of oral rehabilitation |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ243927177 (DE-600)2007587-X |
title |
Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
ctrlnum |
(DE-627)NLEJ243044291 |
title_full |
Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
author_sort |
Takahashi, Y. |
journal |
Journal of oral rehabilitation |
journalStr |
Journal of oral rehabilitation |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
2004 |
contenttype_str_mv |
zzz |
container_start_page |
0 |
author_browse |
Takahashi, Y. Itoh, K. Manabe, A. |
container_volume |
31 |
physical |
Online-Ressource |
format_se |
Elektronische Aufsätze |
author-letter |
Takahashi, Y. |
doi_str_mv |
10.1111/j.1365-2842.2004.01362.x |
author2-role |
verfasserin |
title_sort |
bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
title_auth |
Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
abstract |
summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. |
abstractGer |
summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. |
abstract_unstemmed |
summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding. |
collection_details |
GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE |
container_issue |
12 |
title_short |
Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate |
url |
http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x |
remote_bool |
true |
author2 |
Itoh, K. Manabe, A. Tani, C. Hisamitsu, H. |
author2Str |
Itoh, K. Manabe, A. Tani, C. Hisamitsu, H. |
ppnlink |
NLEJ243927177 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth |
doi_str |
10.1111/j.1365-2842.2004.01362.x |
up_date |
2024-07-06T04:05:26.889Z |
_version_ |
1803801043287408640 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ243044291</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210707171724.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">120427s2004 xx |||||o 00| ||und c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1111/j.1365-2842.2004.01362.x</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ243044291</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Takahashi, Y.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Bonding efficacy and side effects of the high purity glyceryl mono-methacrylate</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Oxford, UK</subfield><subfield code="b">Blackwell Science Ltd</subfield><subfield code="c">2004</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">summary The purpose of this study was to examine the efficacy of experimentally developed high purity glyceryl mono-methacrylate (GM) as a dentine primer and to evaluate the possibility of allergic reaction. The efficacy of experimental dentine primers was evaluated by measuring the polymerization contraction gap width and the tensile bond strength. Allergic reaction was evaluated by the guinea-pig maximization test. The skin reaction was evaluated according to the criteria of the International Contact Dermatitis Research Group. Contraction gap formation was completely prevented and the tensile bond strength was not significantly affected by priming with GM on high-purity GM. The allergic response decreased when high-purity GM was employed as the challenger. It was concluded that the clinical use of the high-purity GM is beneficial as the delayed allergic reaction could be avoided with no detrimental effect on the dentine bonding.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="d">2004</subfield><subfield code="f">Blackwell Publishing Journal Backfiles 1879-2005</subfield><subfield code="7">|2004||||||||||</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">2-hydroxyethyl methacrylate</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Itoh, K.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Manabe, A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Tani, C.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Hisamitsu, H.</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Journal of oral rehabilitation</subfield><subfield code="d">Oxford [u.a.] : Wiley-Blackwell, 1974</subfield><subfield code="g">31(2004), 12, Seite 0</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)NLEJ243927177</subfield><subfield code="w">(DE-600)2007587-X</subfield><subfield code="x">1365-2842</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:31</subfield><subfield code="g">year:2004</subfield><subfield code="g">number:12</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1111/j.1365-2842.2004.01362.x</subfield><subfield code="q">text/html</subfield><subfield code="x">Verlag</subfield><subfield code="z">Deutschlandweit zugänglich</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-DJB</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">31</subfield><subfield code="j">2004</subfield><subfield code="e">12</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
score |
7.398756 |