An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results
We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry...
Ausführliche Beschreibung
Autor*in: |
DANILOVIC, DEJAN [verfasserIn] OHM, OLE-JØRGEN [verfasserIn] STROEBEL, JOHN [verfasserIn] |
---|
Format: |
E-Artikel |
---|
Erschienen: |
Oxford, UK: Blackwell Publishing Ltd ; 1998 |
---|
Schlagwörter: |
---|
Umfang: |
Online-Ressource |
---|
Reproduktion: |
2006 ; Blackwell Publishing Journal Backfiles 1879-2005 |
---|---|
Übergeordnetes Werk: |
In: Pacing and clinical electrophysiology - New York, NY [u.a.] : Wiley-Blackwell, 1978, 21(1998), 5, Seite 0 |
Übergeordnetes Werk: |
volume:21 ; year:1998 ; number:5 ; pages:0 |
Links: |
---|
DOI / URN: |
10.1111/j.1540-8159.1998.tb00151.x |
---|
Katalog-ID: |
NLEJ243917147 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ243917147 | ||
003 | DE-627 | ||
005 | 20210707191417.0 | ||
007 | cr uuu---uuuuu | ||
008 | 120427s1998 xx |||||o 00| ||und c | ||
024 | 7 | |a 10.1111/j.1540-8159.1998.tb00151.x |2 doi | |
035 | |a (DE-627)NLEJ243917147 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
100 | 1 | |a DANILOVIC, DEJAN |e verfasserin |4 aut | |
245 | 1 | 0 | |a An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results |
264 | 1 | |a Oxford, UK |b Blackwell Publishing Ltd |c 1998 | |
300 | |a Online-Ressource | ||
336 | |a nicht spezifiziert |b zzz |2 rdacontent | ||
337 | |a nicht spezifiziert |b z |2 rdamedia | ||
338 | |a nicht spezifiziert |b zu |2 rdacarrier | ||
520 | |a We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. | ||
533 | |d 2006 |f Blackwell Publishing Journal Backfiles 1879-2005 |7 |2006|||||||||| | ||
650 | 4 | |a automatic threshold measurement | |
700 | 1 | |a OHM, OLE-JØRGEN |e verfasserin |4 aut | |
700 | 1 | |a STROEBEL, JOHN |e verfasserin |4 aut | |
700 | 1 | |a BREIVIK, KJELL |4 oth | |
700 | 1 | |a HOFF, PER IVAR |4 oth | |
700 | 1 | |a MARKOWITZ, TOBY |4 oth | |
773 | 0 | 8 | |i In |t Pacing and clinical electrophysiology |d New York, NY [u.a.] : Wiley-Blackwell, 1978 |g 21(1998), 5, Seite 0 |h Online-Ressource |w (DE-627)NLEJ243926928 |w (DE-600)2037547-5 |x 1540-8159 |7 nnns |
773 | 1 | 8 | |g volume:21 |g year:1998 |g number:5 |g pages:0 |
856 | 4 | 0 | |u http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x |q text/html |x Verlag |z Deutschlandweit zugänglich |3 Volltext |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-DJB | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 21 |j 1998 |e 5 |h 0 |
author_variant |
d d dd o j o ojo j s js |
---|---|
matchkey_str |
article:15408159:1998----::nloihfruoaimaueetftmltotrsodciiaprom |
hierarchy_sort_str |
1998 |
publishDate |
1998 |
allfields |
10.1111/j.1540-8159.1998.tb00151.x doi (DE-627)NLEJ243917147 DE-627 ger DE-627 rakwb DANILOVIC, DEJAN verfasserin aut An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results Oxford, UK Blackwell Publishing Ltd 1998 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. 2006 Blackwell Publishing Journal Backfiles 1879-2005 |2006|||||||||| automatic threshold measurement OHM, OLE-JØRGEN verfasserin aut STROEBEL, JOHN verfasserin aut BREIVIK, KJELL oth HOFF, PER IVAR oth MARKOWITZ, TOBY oth In Pacing and clinical electrophysiology New York, NY [u.a.] : Wiley-Blackwell, 1978 21(1998), 5, Seite 0 Online-Ressource (DE-627)NLEJ243926928 (DE-600)2037547-5 1540-8159 nnns volume:21 year:1998 number:5 pages:0 http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 21 1998 5 0 |
spelling |
10.1111/j.1540-8159.1998.tb00151.x doi (DE-627)NLEJ243917147 DE-627 ger DE-627 rakwb DANILOVIC, DEJAN verfasserin aut An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results Oxford, UK Blackwell Publishing Ltd 1998 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. 2006 Blackwell Publishing Journal Backfiles 1879-2005 |2006|||||||||| automatic threshold measurement OHM, OLE-JØRGEN verfasserin aut STROEBEL, JOHN verfasserin aut BREIVIK, KJELL oth HOFF, PER IVAR oth MARKOWITZ, TOBY oth In Pacing and clinical electrophysiology New York, NY [u.a.] : Wiley-Blackwell, 1978 21(1998), 5, Seite 0 Online-Ressource (DE-627)NLEJ243926928 (DE-600)2037547-5 1540-8159 nnns volume:21 year:1998 number:5 pages:0 http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 21 1998 5 0 |
allfields_unstemmed |
10.1111/j.1540-8159.1998.tb00151.x doi (DE-627)NLEJ243917147 DE-627 ger DE-627 rakwb DANILOVIC, DEJAN verfasserin aut An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results Oxford, UK Blackwell Publishing Ltd 1998 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. 2006 Blackwell Publishing Journal Backfiles 1879-2005 |2006|||||||||| automatic threshold measurement OHM, OLE-JØRGEN verfasserin aut STROEBEL, JOHN verfasserin aut BREIVIK, KJELL oth HOFF, PER IVAR oth MARKOWITZ, TOBY oth In Pacing and clinical electrophysiology New York, NY [u.a.] : Wiley-Blackwell, 1978 21(1998), 5, Seite 0 Online-Ressource (DE-627)NLEJ243926928 (DE-600)2037547-5 1540-8159 nnns volume:21 year:1998 number:5 pages:0 http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 21 1998 5 0 |
allfieldsGer |
10.1111/j.1540-8159.1998.tb00151.x doi (DE-627)NLEJ243917147 DE-627 ger DE-627 rakwb DANILOVIC, DEJAN verfasserin aut An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results Oxford, UK Blackwell Publishing Ltd 1998 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. 2006 Blackwell Publishing Journal Backfiles 1879-2005 |2006|||||||||| automatic threshold measurement OHM, OLE-JØRGEN verfasserin aut STROEBEL, JOHN verfasserin aut BREIVIK, KJELL oth HOFF, PER IVAR oth MARKOWITZ, TOBY oth In Pacing and clinical electrophysiology New York, NY [u.a.] : Wiley-Blackwell, 1978 21(1998), 5, Seite 0 Online-Ressource (DE-627)NLEJ243926928 (DE-600)2037547-5 1540-8159 nnns volume:21 year:1998 number:5 pages:0 http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 21 1998 5 0 |
allfieldsSound |
10.1111/j.1540-8159.1998.tb00151.x doi (DE-627)NLEJ243917147 DE-627 ger DE-627 rakwb DANILOVIC, DEJAN verfasserin aut An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results Oxford, UK Blackwell Publishing Ltd 1998 Online-Ressource nicht spezifiziert zzz rdacontent nicht spezifiziert z rdamedia nicht spezifiziert zu rdacarrier We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. 2006 Blackwell Publishing Journal Backfiles 1879-2005 |2006|||||||||| automatic threshold measurement OHM, OLE-JØRGEN verfasserin aut STROEBEL, JOHN verfasserin aut BREIVIK, KJELL oth HOFF, PER IVAR oth MARKOWITZ, TOBY oth In Pacing and clinical electrophysiology New York, NY [u.a.] : Wiley-Blackwell, 1978 21(1998), 5, Seite 0 Online-Ressource (DE-627)NLEJ243926928 (DE-600)2037547-5 1540-8159 nnns volume:21 year:1998 number:5 pages:0 http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x text/html Verlag Deutschlandweit zugänglich Volltext GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE AR 21 1998 5 0 |
source |
In Pacing and clinical electrophysiology 21(1998), 5, Seite 0 volume:21 year:1998 number:5 pages:0 |
sourceStr |
In Pacing and clinical electrophysiology 21(1998), 5, Seite 0 volume:21 year:1998 number:5 pages:0 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
automatic threshold measurement |
isfreeaccess_bool |
false |
container_title |
Pacing and clinical electrophysiology |
authorswithroles_txt_mv |
DANILOVIC, DEJAN @@aut@@ OHM, OLE-JØRGEN @@aut@@ STROEBEL, JOHN @@aut@@ BREIVIK, KJELL @@oth@@ HOFF, PER IVAR @@oth@@ MARKOWITZ, TOBY @@oth@@ |
publishDateDaySort_date |
1998-01-01T00:00:00Z |
hierarchy_top_id |
NLEJ243926928 |
id |
NLEJ243917147 |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ243917147</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210707191417.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">120427s1998 xx |||||o 00| ||und c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1111/j.1540-8159.1998.tb00151.x</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ243917147</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">DANILOVIC, DEJAN</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Oxford, UK</subfield><subfield code="b">Blackwell Publishing Ltd</subfield><subfield code="c">1998</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="d">2006</subfield><subfield code="f">Blackwell Publishing Journal Backfiles 1879-2005</subfield><subfield code="7">|2006||||||||||</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">automatic threshold measurement</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">OHM, OLE-JØRGEN</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">STROEBEL, JOHN</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">BREIVIK, KJELL</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">HOFF, PER IVAR</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">MARKOWITZ, TOBY</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Pacing and clinical electrophysiology</subfield><subfield code="d">New York, NY [u.a.] : Wiley-Blackwell, 1978</subfield><subfield code="g">21(1998), 5, Seite 0</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)NLEJ243926928</subfield><subfield code="w">(DE-600)2037547-5</subfield><subfield code="x">1540-8159</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:21</subfield><subfield code="g">year:1998</subfield><subfield code="g">number:5</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x</subfield><subfield code="q">text/html</subfield><subfield code="x">Verlag</subfield><subfield code="z">Deutschlandweit zugänglich</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-DJB</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">21</subfield><subfield code="j">1998</subfield><subfield code="e">5</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
series2 |
Blackwell Publishing Journal Backfiles 1879-2005 |
author |
DANILOVIC, DEJAN |
spellingShingle |
DANILOVIC, DEJAN misc automatic threshold measurement An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results |
authorStr |
DANILOVIC, DEJAN |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ243926928 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut |
collection |
NL |
publishPlace |
Oxford, UK |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1540-8159 |
topic_title |
An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results automatic threshold measurement |
publisher |
Blackwell Publishing Ltd |
publisherStr |
Blackwell Publishing Ltd |
topic |
misc automatic threshold measurement |
topic_unstemmed |
misc automatic threshold measurement |
topic_browse |
misc automatic threshold measurement |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
zu |
author2_variant |
k b kb p i h pi pih t m tm |
hierarchy_parent_title |
Pacing and clinical electrophysiology |
hierarchy_parent_id |
NLEJ243926928 |
hierarchy_top_title |
Pacing and clinical electrophysiology |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ243926928 (DE-600)2037547-5 |
title |
An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results |
ctrlnum |
(DE-627)NLEJ243917147 |
title_full |
An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results |
author_sort |
DANILOVIC, DEJAN |
journal |
Pacing and clinical electrophysiology |
journalStr |
Pacing and clinical electrophysiology |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
1998 |
contenttype_str_mv |
zzz |
container_start_page |
0 |
author_browse |
DANILOVIC, DEJAN OHM, OLE-JØRGEN STROEBEL, JOHN |
container_volume |
21 |
physical |
Online-Ressource |
format_se |
Elektronische Aufsätze |
author-letter |
DANILOVIC, DEJAN |
doi_str_mv |
10.1111/j.1540-8159.1998.tb00151.x |
author2-role |
verfasserin |
title_sort |
an algorithm for automatic measurement of stimulation thresholds: clinical performance and preliminary results |
title_auth |
An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results |
abstract |
We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. |
abstractGer |
We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. |
abstract_unstemmed |
We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds. |
collection_details |
GBV_USEFLAG_U ZDB-1-DJB GBV_NL_ARTICLE |
container_issue |
5 |
title_short |
An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results |
url |
http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x |
remote_bool |
true |
author2 |
OHM, OLE-JØRGEN STROEBEL, JOHN BREIVIK, KJELL HOFF, PER IVAR MARKOWITZ, TOBY |
author2Str |
OHM, OLE-JØRGEN STROEBEL, JOHN BREIVIK, KJELL HOFF, PER IVAR MARKOWITZ, TOBY |
ppnlink |
NLEJ243926928 |
mediatype_str_mv |
z |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth oth oth |
doi_str |
10.1111/j.1540-8159.1998.tb00151.x |
up_date |
2024-07-06T06:56:30.277Z |
_version_ |
1803811805230792704 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ243917147</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20210707191417.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">120427s1998 xx |||||o 00| ||und c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1111/j.1540-8159.1998.tb00151.x</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ243917147</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">DANILOVIC, DEJAN</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">An Algorithm for Automatic Measurement of Stimulation Thresholds: Clinical Performance and Preliminary Results</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="a">Oxford, UK</subfield><subfield code="b">Blackwell Publishing Ltd</subfield><subfield code="c">1998</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zzz</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">z</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">nicht spezifiziert</subfield><subfield code="b">zu</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">We have developed an algorithmic method for automatic determination of stimulation thresholds in both cardiac chambers in patients with intact atrioventricular (AV) conduction. The algorithm utilizes ventricular sensing, may be used with any type of pacing leads, and may be downloaded via telemetry links into already implanted dual-chamber Thera® pacemakers. Thresholds are determined with 0.5 V amplitude and 0.06 ms pulse-width resolution in unipolar, bipolar, or both lead configurations, with a programmable sampling interval from 2 minutes to 48 hours. Measured values are stored in the pacemaker memory for later retrieval and do not influence permanent output settings. The algorithm was intended to gather information on continuous behavior of stimulation thresholds, which is important in the formation of strategies for programming pacemaker outputs. Clinical performance of the algorithm was evaluated in eight patients who received bipolar tined steroid-eluting leads and were observed for a mean of 5.1 months. Patient safety was not compromised by the algorithm, except for the possibility of pacing during the physiologic refractory period. Methods for discrimination of incorrect data points were developed and incorrect values were discarded. Fine resolution threshold measurements collected during this study indicated that: (1) there were great differences in magnitude of threshold peaking in different patients; (2) the initial intensive threshold peaking was usually followed by another less intensive but longer-lasting wave of threshold peaking; (3) the pattern of tissue reaction in the atrium appeared different from that in the ventricle; and (4) threshold peaking in the bipolar lead configuration was greater than in the unipolar configuration. The algorithm proved to be useful in studying ambulatory thresholds.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="d">2006</subfield><subfield code="f">Blackwell Publishing Journal Backfiles 1879-2005</subfield><subfield code="7">|2006||||||||||</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">automatic threshold measurement</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">OHM, OLE-JØRGEN</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">STROEBEL, JOHN</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">BREIVIK, KJELL</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">HOFF, PER IVAR</subfield><subfield code="4">oth</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">MARKOWITZ, TOBY</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">In</subfield><subfield code="t">Pacing and clinical electrophysiology</subfield><subfield code="d">New York, NY [u.a.] : Wiley-Blackwell, 1978</subfield><subfield code="g">21(1998), 5, Seite 0</subfield><subfield code="h">Online-Ressource</subfield><subfield code="w">(DE-627)NLEJ243926928</subfield><subfield code="w">(DE-600)2037547-5</subfield><subfield code="x">1540-8159</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:21</subfield><subfield code="g">year:1998</subfield><subfield code="g">number:5</subfield><subfield code="g">pages:0</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">http://dx.doi.org/10.1111/j.1540-8159.1998.tb00151.x</subfield><subfield code="q">text/html</subfield><subfield code="x">Verlag</subfield><subfield code="z">Deutschlandweit zugänglich</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-DJB</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">21</subfield><subfield code="j">1998</subfield><subfield code="e">5</subfield><subfield code="h">0</subfield></datafield></record></collection>
|
score |
7.399255 |