Bilirubin measurement – an updated survey1
The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole...
Ausführliche Beschreibung
Autor*in: |
Thaler, Markus [verfasserIn] Luppa, Peter B. [verfasserIn] Schlebusch, Harald [verfasserIn] |
---|
Format: |
E-Artikel |
---|
Erschienen: |
Walter de Gruyter ; 2008 |
---|
Schlagwörter: |
---|
Anmerkung: |
©2008 by Walter de Gruyter Berlin New York |
---|
Reproduktion: |
Walter de Gruyter Online Zeitschriften |
---|---|
Übergeordnetes Werk: |
Enthalten in: Laboratoriumsmedizin - Berlin [u.a.] : de Gruyter, 1977, 32(2008), 1 vom: 24. Okt., Seite --- |
Übergeordnetes Werk: |
volume:32 ; year:2008 ; number:1 ; day:24 ; month:10 ; pages:--- |
Links: |
---|
DOI / URN: |
10.1515/JLM.2008.005et |
---|
Katalog-ID: |
NLEJ248060708 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | NLEJ248060708 | ||
003 | DE-627 | ||
005 | 20220820035536.0 | ||
007 | cr uuu---uuuuu | ||
008 | 220814s2008 xx |||||o 00| ||und c | ||
024 | 7 | |a 10.1515/JLM.2008.005et |2 doi | |
028 | 5 | 2 | |a articles2015-2020.pp |
035 | |a (DE-627)NLEJ248060708 | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
100 | 1 | |a Thaler, Markus |e verfasserin |4 aut | |
245 | 1 | 0 | |a Bilirubin measurement – an updated survey1 |
264 | 1 | |b Walter de Gruyter |c 2008 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a Computermedien |b c |2 rdamedia | ||
338 | |a Online-Ressource |b cr |2 rdacarrier | ||
500 | |a ©2008 by Walter de Gruyter Berlin New York | ||
520 | |a The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. | ||
533 | |f Walter de Gruyter Online Zeitschriften | ||
650 | 4 | |a bilirubin | |
650 | 4 | |a methods | |
650 | 4 | |a point-of-care diagnostics | |
700 | 1 | |a Luppa, Peter B. |e verfasserin |4 aut | |
700 | 1 | |a Schlebusch, Harald |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Laboratoriumsmedizin |d Berlin [u.a.] : de Gruyter, 1977 |g 32(2008), 1 vom: 24. Okt., Seite --- |w (DE-627)NLEJ248236334 |w (DE-600)2081704-6 |x 1439-0477 |7 nnns |
773 | 1 | 8 | |g volume:32 |g year:2008 |g number:1 |g day:24 |g month:10 |g pages:--- |
856 | 4 | 0 | |u https://doi.org/10.1515/JLM.2008.005et |z Deutschlandweit zugänglich |
912 | |a GBV_USEFLAG_U | ||
912 | |a ZDB-1-DGR | ||
912 | |a GBV_NL_ARTICLE | ||
951 | |a AR | ||
952 | |d 32 |j 2008 |e 1 |b 24 |c 10 |h --- |
author_variant |
m t mt p b l pb pbl h s hs |
---|---|
matchkey_str |
article:14390477:2008----::iiuimaueetnpa |
hierarchy_sort_str |
2008 |
publishDate |
2008 |
allfields |
10.1515/JLM.2008.005et doi articles2015-2020.pp (DE-627)NLEJ248060708 DE-627 ger DE-627 rakwb Thaler, Markus verfasserin aut Bilirubin measurement – an updated survey1 Walter de Gruyter 2008 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier ©2008 by Walter de Gruyter Berlin New York The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. Walter de Gruyter Online Zeitschriften bilirubin methods point-of-care diagnostics Luppa, Peter B. verfasserin aut Schlebusch, Harald verfasserin aut Enthalten in Laboratoriumsmedizin Berlin [u.a.] : de Gruyter, 1977 32(2008), 1 vom: 24. Okt., Seite --- (DE-627)NLEJ248236334 (DE-600)2081704-6 1439-0477 nnns volume:32 year:2008 number:1 day:24 month:10 pages:--- https://doi.org/10.1515/JLM.2008.005et Deutschlandweit zugänglich GBV_USEFLAG_U ZDB-1-DGR GBV_NL_ARTICLE AR 32 2008 1 24 10 --- |
spelling |
10.1515/JLM.2008.005et doi articles2015-2020.pp (DE-627)NLEJ248060708 DE-627 ger DE-627 rakwb Thaler, Markus verfasserin aut Bilirubin measurement – an updated survey1 Walter de Gruyter 2008 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier ©2008 by Walter de Gruyter Berlin New York The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. Walter de Gruyter Online Zeitschriften bilirubin methods point-of-care diagnostics Luppa, Peter B. verfasserin aut Schlebusch, Harald verfasserin aut Enthalten in Laboratoriumsmedizin Berlin [u.a.] : de Gruyter, 1977 32(2008), 1 vom: 24. Okt., Seite --- (DE-627)NLEJ248236334 (DE-600)2081704-6 1439-0477 nnns volume:32 year:2008 number:1 day:24 month:10 pages:--- https://doi.org/10.1515/JLM.2008.005et Deutschlandweit zugänglich GBV_USEFLAG_U ZDB-1-DGR GBV_NL_ARTICLE AR 32 2008 1 24 10 --- |
allfields_unstemmed |
10.1515/JLM.2008.005et doi articles2015-2020.pp (DE-627)NLEJ248060708 DE-627 ger DE-627 rakwb Thaler, Markus verfasserin aut Bilirubin measurement – an updated survey1 Walter de Gruyter 2008 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier ©2008 by Walter de Gruyter Berlin New York The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. Walter de Gruyter Online Zeitschriften bilirubin methods point-of-care diagnostics Luppa, Peter B. verfasserin aut Schlebusch, Harald verfasserin aut Enthalten in Laboratoriumsmedizin Berlin [u.a.] : de Gruyter, 1977 32(2008), 1 vom: 24. Okt., Seite --- (DE-627)NLEJ248236334 (DE-600)2081704-6 1439-0477 nnns volume:32 year:2008 number:1 day:24 month:10 pages:--- https://doi.org/10.1515/JLM.2008.005et Deutschlandweit zugänglich GBV_USEFLAG_U ZDB-1-DGR GBV_NL_ARTICLE AR 32 2008 1 24 10 --- |
allfieldsGer |
10.1515/JLM.2008.005et doi articles2015-2020.pp (DE-627)NLEJ248060708 DE-627 ger DE-627 rakwb Thaler, Markus verfasserin aut Bilirubin measurement – an updated survey1 Walter de Gruyter 2008 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier ©2008 by Walter de Gruyter Berlin New York The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. Walter de Gruyter Online Zeitschriften bilirubin methods point-of-care diagnostics Luppa, Peter B. verfasserin aut Schlebusch, Harald verfasserin aut Enthalten in Laboratoriumsmedizin Berlin [u.a.] : de Gruyter, 1977 32(2008), 1 vom: 24. Okt., Seite --- (DE-627)NLEJ248236334 (DE-600)2081704-6 1439-0477 nnns volume:32 year:2008 number:1 day:24 month:10 pages:--- https://doi.org/10.1515/JLM.2008.005et Deutschlandweit zugänglich GBV_USEFLAG_U ZDB-1-DGR GBV_NL_ARTICLE AR 32 2008 1 24 10 --- |
allfieldsSound |
10.1515/JLM.2008.005et doi articles2015-2020.pp (DE-627)NLEJ248060708 DE-627 ger DE-627 rakwb Thaler, Markus verfasserin aut Bilirubin measurement – an updated survey1 Walter de Gruyter 2008 Text txt rdacontent Computermedien c rdamedia Online-Ressource cr rdacarrier ©2008 by Walter de Gruyter Berlin New York The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. Walter de Gruyter Online Zeitschriften bilirubin methods point-of-care diagnostics Luppa, Peter B. verfasserin aut Schlebusch, Harald verfasserin aut Enthalten in Laboratoriumsmedizin Berlin [u.a.] : de Gruyter, 1977 32(2008), 1 vom: 24. Okt., Seite --- (DE-627)NLEJ248236334 (DE-600)2081704-6 1439-0477 nnns volume:32 year:2008 number:1 day:24 month:10 pages:--- https://doi.org/10.1515/JLM.2008.005et Deutschlandweit zugänglich GBV_USEFLAG_U ZDB-1-DGR GBV_NL_ARTICLE AR 32 2008 1 24 10 --- |
source |
Enthalten in Laboratoriumsmedizin 32(2008), 1 vom: 24. Okt., Seite --- volume:32 year:2008 number:1 day:24 month:10 pages:--- |
sourceStr |
Enthalten in Laboratoriumsmedizin 32(2008), 1 vom: 24. Okt., Seite --- volume:32 year:2008 number:1 day:24 month:10 pages:--- |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
bilirubin methods point-of-care diagnostics |
isfreeaccess_bool |
false |
container_title |
Laboratoriumsmedizin |
authorswithroles_txt_mv |
Thaler, Markus @@aut@@ Luppa, Peter B. @@aut@@ Schlebusch, Harald @@aut@@ |
publishDateDaySort_date |
2008-10-24T00:00:00Z |
hierarchy_top_id |
NLEJ248236334 |
id |
NLEJ248060708 |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ248060708</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20220820035536.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">220814s2008 xx |||||o 00| ||und c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1515/JLM.2008.005et</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">articles2015-2020.pp</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ248060708</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Thaler, Markus</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Bilirubin measurement – an updated survey1</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="b">Walter de Gruyter</subfield><subfield code="c">2008</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">©2008 by Walter de Gruyter Berlin New York</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Walter de Gruyter Online Zeitschriften</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">bilirubin</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">methods</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">point-of-care diagnostics</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Luppa, Peter B.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schlebusch, Harald</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Laboratoriumsmedizin</subfield><subfield code="d">Berlin [u.a.] : de Gruyter, 1977</subfield><subfield code="g">32(2008), 1 vom: 24. Okt., Seite ---</subfield><subfield code="w">(DE-627)NLEJ248236334</subfield><subfield code="w">(DE-600)2081704-6</subfield><subfield code="x">1439-0477</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:32</subfield><subfield code="g">year:2008</subfield><subfield code="g">number:1</subfield><subfield code="g">day:24</subfield><subfield code="g">month:10</subfield><subfield code="g">pages:---</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1515/JLM.2008.005et</subfield><subfield code="z">Deutschlandweit zugänglich</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-DGR</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">32</subfield><subfield code="j">2008</subfield><subfield code="e">1</subfield><subfield code="b">24</subfield><subfield code="c">10</subfield><subfield code="h">---</subfield></datafield></record></collection>
|
series2 |
Walter de Gruyter Online Zeitschriften |
author |
Thaler, Markus |
spellingShingle |
Thaler, Markus misc bilirubin misc methods misc point-of-care diagnostics Bilirubin measurement – an updated survey1 |
authorStr |
Thaler, Markus |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)NLEJ248236334 |
format |
electronic Article |
delete_txt_mv |
keep |
author_role |
aut aut aut |
collection |
NL |
remote_str |
true |
illustrated |
Not Illustrated |
issn |
1439-0477 |
topic_title |
Bilirubin measurement – an updated survey1 bilirubin methods point-of-care diagnostics |
publisher |
Walter de Gruyter |
publisherStr |
Walter de Gruyter |
topic |
misc bilirubin misc methods misc point-of-care diagnostics |
topic_unstemmed |
misc bilirubin misc methods misc point-of-care diagnostics |
topic_browse |
misc bilirubin misc methods misc point-of-care diagnostics |
format_facet |
Elektronische Aufsätze Aufsätze Elektronische Ressource |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
cr |
hierarchy_parent_title |
Laboratoriumsmedizin |
hierarchy_parent_id |
NLEJ248236334 |
hierarchy_top_title |
Laboratoriumsmedizin |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)NLEJ248236334 (DE-600)2081704-6 |
title |
Bilirubin measurement – an updated survey1 |
ctrlnum |
(DE-627)NLEJ248060708 |
title_full |
Bilirubin measurement – an updated survey1 |
author_sort |
Thaler, Markus |
journal |
Laboratoriumsmedizin |
journalStr |
Laboratoriumsmedizin |
isOA_bool |
false |
recordtype |
marc |
publishDateSort |
2008 |
contenttype_str_mv |
txt |
author_browse |
Thaler, Markus Luppa, Peter B. Schlebusch, Harald |
container_volume |
32 |
format_se |
Elektronische Aufsätze |
author-letter |
Thaler, Markus |
doi_str_mv |
10.1515/JLM.2008.005et |
author2-role |
verfasserin |
title_sort |
bilirubin measurement – an updated survey1 |
title_auth |
Bilirubin measurement – an updated survey1 |
abstract |
The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. ©2008 by Walter de Gruyter Berlin New York |
abstractGer |
The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. ©2008 by Walter de Gruyter Berlin New York |
abstract_unstemmed |
The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses. ©2008 by Walter de Gruyter Berlin New York |
collection_details |
GBV_USEFLAG_U ZDB-1-DGR GBV_NL_ARTICLE |
container_issue |
1 |
title_short |
Bilirubin measurement – an updated survey1 |
url |
https://doi.org/10.1515/JLM.2008.005et |
remote_bool |
true |
author2 |
Luppa, Peter B. Schlebusch, Harald |
author2Str |
Luppa, Peter B. Schlebusch, Harald |
ppnlink |
NLEJ248236334 |
mediatype_str_mv |
c |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1515/JLM.2008.005et |
up_date |
2024-07-05T22:28:44.964Z |
_version_ |
1803779860035796993 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">NLEJ248060708</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20220820035536.0</controlfield><controlfield tag="007">cr uuu---uuuuu</controlfield><controlfield tag="008">220814s2008 xx |||||o 00| ||und c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1515/JLM.2008.005et</subfield><subfield code="2">doi</subfield></datafield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">articles2015-2020.pp</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)NLEJ248060708</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Thaler, Markus</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Bilirubin measurement – an updated survey1</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="b">Walter de Gruyter</subfield><subfield code="c">2008</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">Computermedien</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Online-Ressource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">©2008 by Walter de Gruyter Berlin New York</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">The goal of precise, accurate and specific measurement of bilirubin and its subfractions in serum has not yet been achieved, despite many different methods being available. In addition to the traditional photometric diazo procedures, drychemistry methods, direct spectro-photometry in serum and whole blood and for scientific purposes separations by HPLC were established. For point-of-care diagnostics several test procedures are available. This article reviews the most notable methods and describes advantages and disadvantages of the different bilirubin analyses.</subfield></datafield><datafield tag="533" ind1=" " ind2=" "><subfield code="f">Walter de Gruyter Online Zeitschriften</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">bilirubin</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">methods</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">point-of-care diagnostics</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Luppa, Peter B.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Schlebusch, Harald</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Laboratoriumsmedizin</subfield><subfield code="d">Berlin [u.a.] : de Gruyter, 1977</subfield><subfield code="g">32(2008), 1 vom: 24. Okt., Seite ---</subfield><subfield code="w">(DE-627)NLEJ248236334</subfield><subfield code="w">(DE-600)2081704-6</subfield><subfield code="x">1439-0477</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:32</subfield><subfield code="g">year:2008</subfield><subfield code="g">number:1</subfield><subfield code="g">day:24</subfield><subfield code="g">month:10</subfield><subfield code="g">pages:---</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="u">https://doi.org/10.1515/JLM.2008.005et</subfield><subfield code="z">Deutschlandweit zugänglich</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_U</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">ZDB-1-DGR</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_NL_ARTICLE</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">32</subfield><subfield code="j">2008</subfield><subfield code="e">1</subfield><subfield code="b">24</subfield><subfield code="c">10</subfield><subfield code="h">---</subfield></datafield></record></collection>
|
score |
7.400589 |