Note: Cryogenic heat switch with stepper motor actuator
A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at tempera...
Ausführliche Beschreibung
Autor*in: |
Melcher, B S [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2015 |
---|
Übergeordnetes Werk: |
Enthalten in: Review of scientific instruments - Melville, NY : AIP, 1930, 86(2015), 12 |
---|---|
Übergeordnetes Werk: |
volume:86 ; year:2015 ; number:12 |
Links: |
---|
Katalog-ID: |
OLC196336239X |
---|
LEADER | 01000caa a2200265 4500 | ||
---|---|---|---|
001 | OLC196336239X | ||
003 | DE-627 | ||
005 | 20230714160925.0 | ||
007 | tu | ||
008 | 160206s2015 xx ||||| 00| ||eng c | ||
028 | 5 | 2 | |a PQ20160617 |
035 | |a (DE-627)OLC196336239X | ||
035 | |a (DE-599)GBVOLC196336239X | ||
035 | |a (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 | ||
035 | |a (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 530 |a 620 |q DNB |
100 | 1 | |a Melcher, B S |e verfasserin |4 aut | |
245 | 1 | 0 | |a Note: Cryogenic heat switch with stepper motor actuator |
264 | 1 | |c 2015 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
520 | |a A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. | ||
700 | 1 | |a Timbie, P T |4 oth | |
773 | 0 | 8 | |i Enthalten in |t Review of scientific instruments |d Melville, NY : AIP, 1930 |g 86(2015), 12 |w (DE-627)129509175 |w (DE-600)209865-9 |w (DE-576)014915782 |x 0034-6748 |7 nnns |
773 | 1 | 8 | |g volume:86 |g year:2015 |g number:12 |
856 | 4 | 2 | |u http://www.ncbi.nlm.nih.gov/pubmed/26724093 |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-TEC | ||
912 | |a SSG-OLC-PHY | ||
912 | |a GBV_ILN_21 | ||
912 | |a GBV_ILN_47 | ||
912 | |a GBV_ILN_59 | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_170 | ||
912 | |a GBV_ILN_2219 | ||
912 | |a GBV_ILN_2279 | ||
912 | |a GBV_ILN_4306 | ||
912 | |a GBV_ILN_4310 | ||
951 | |a AR | ||
952 | |d 86 |j 2015 |e 12 |
author_variant |
b s m bs bsm |
---|---|
matchkey_str |
article:00346748:2015----::oeroeihasicwtsep |
hierarchy_sort_str |
2015 |
publishDate |
2015 |
allfields |
PQ20160617 (DE-627)OLC196336239X (DE-599)GBVOLC196336239X (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator DE-627 ger DE-627 rakwb eng 530 620 DNB Melcher, B S verfasserin aut Note: Cryogenic heat switch with stepper motor actuator 2015 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. Timbie, P T oth Enthalten in Review of scientific instruments Melville, NY : AIP, 1930 86(2015), 12 (DE-627)129509175 (DE-600)209865-9 (DE-576)014915782 0034-6748 nnns volume:86 year:2015 number:12 http://www.ncbi.nlm.nih.gov/pubmed/26724093 GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_47 GBV_ILN_59 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2219 GBV_ILN_2279 GBV_ILN_4306 GBV_ILN_4310 AR 86 2015 12 |
spelling |
PQ20160617 (DE-627)OLC196336239X (DE-599)GBVOLC196336239X (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator DE-627 ger DE-627 rakwb eng 530 620 DNB Melcher, B S verfasserin aut Note: Cryogenic heat switch with stepper motor actuator 2015 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. Timbie, P T oth Enthalten in Review of scientific instruments Melville, NY : AIP, 1930 86(2015), 12 (DE-627)129509175 (DE-600)209865-9 (DE-576)014915782 0034-6748 nnns volume:86 year:2015 number:12 http://www.ncbi.nlm.nih.gov/pubmed/26724093 GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_47 GBV_ILN_59 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2219 GBV_ILN_2279 GBV_ILN_4306 GBV_ILN_4310 AR 86 2015 12 |
allfields_unstemmed |
PQ20160617 (DE-627)OLC196336239X (DE-599)GBVOLC196336239X (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator DE-627 ger DE-627 rakwb eng 530 620 DNB Melcher, B S verfasserin aut Note: Cryogenic heat switch with stepper motor actuator 2015 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. Timbie, P T oth Enthalten in Review of scientific instruments Melville, NY : AIP, 1930 86(2015), 12 (DE-627)129509175 (DE-600)209865-9 (DE-576)014915782 0034-6748 nnns volume:86 year:2015 number:12 http://www.ncbi.nlm.nih.gov/pubmed/26724093 GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_47 GBV_ILN_59 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2219 GBV_ILN_2279 GBV_ILN_4306 GBV_ILN_4310 AR 86 2015 12 |
allfieldsGer |
PQ20160617 (DE-627)OLC196336239X (DE-599)GBVOLC196336239X (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator DE-627 ger DE-627 rakwb eng 530 620 DNB Melcher, B S verfasserin aut Note: Cryogenic heat switch with stepper motor actuator 2015 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. Timbie, P T oth Enthalten in Review of scientific instruments Melville, NY : AIP, 1930 86(2015), 12 (DE-627)129509175 (DE-600)209865-9 (DE-576)014915782 0034-6748 nnns volume:86 year:2015 number:12 http://www.ncbi.nlm.nih.gov/pubmed/26724093 GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_47 GBV_ILN_59 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2219 GBV_ILN_2279 GBV_ILN_4306 GBV_ILN_4310 AR 86 2015 12 |
allfieldsSound |
PQ20160617 (DE-627)OLC196336239X (DE-599)GBVOLC196336239X (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator DE-627 ger DE-627 rakwb eng 530 620 DNB Melcher, B S verfasserin aut Note: Cryogenic heat switch with stepper motor actuator 2015 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. Timbie, P T oth Enthalten in Review of scientific instruments Melville, NY : AIP, 1930 86(2015), 12 (DE-627)129509175 (DE-600)209865-9 (DE-576)014915782 0034-6748 nnns volume:86 year:2015 number:12 http://www.ncbi.nlm.nih.gov/pubmed/26724093 GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_47 GBV_ILN_59 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2219 GBV_ILN_2279 GBV_ILN_4306 GBV_ILN_4310 AR 86 2015 12 |
language |
English |
source |
Enthalten in Review of scientific instruments 86(2015), 12 volume:86 year:2015 number:12 |
sourceStr |
Enthalten in Review of scientific instruments 86(2015), 12 volume:86 year:2015 number:12 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
dewey-raw |
530 |
isfreeaccess_bool |
false |
container_title |
Review of scientific instruments |
authorswithroles_txt_mv |
Melcher, B S @@aut@@ Timbie, P T @@oth@@ |
publishDateDaySort_date |
2015-01-01T00:00:00Z |
hierarchy_top_id |
129509175 |
dewey-sort |
3530 |
id |
OLC196336239X |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a2200265 4500</leader><controlfield tag="001">OLC196336239X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230714160925.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">160206s2015 xx ||||| 00| ||eng c</controlfield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">PQ20160617</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC196336239X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVOLC196336239X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="a">620</subfield><subfield code="q">DNB</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Melcher, B S</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Note: Cryogenic heat switch with stepper motor actuator</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2015</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Timbie, P T</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Review of scientific instruments</subfield><subfield code="d">Melville, NY : AIP, 1930</subfield><subfield code="g">86(2015), 12</subfield><subfield code="w">(DE-627)129509175</subfield><subfield code="w">(DE-600)209865-9</subfield><subfield code="w">(DE-576)014915782</subfield><subfield code="x">0034-6748</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:86</subfield><subfield code="g">year:2015</subfield><subfield code="g">number:12</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">http://www.ncbi.nlm.nih.gov/pubmed/26724093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_21</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_47</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_59</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2219</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2279</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4310</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">86</subfield><subfield code="j">2015</subfield><subfield code="e">12</subfield></datafield></record></collection>
|
author |
Melcher, B S |
spellingShingle |
Melcher, B S ddc 530 Note: Cryogenic heat switch with stepper motor actuator |
authorStr |
Melcher, B S |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)129509175 |
format |
Article |
dewey-ones |
530 - Physics 620 - Engineering & allied operations |
delete_txt_mv |
keep |
author_role |
aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0034-6748 |
topic_title |
530 620 DNB Note: Cryogenic heat switch with stepper motor actuator |
topic |
ddc 530 |
topic_unstemmed |
ddc 530 |
topic_browse |
ddc 530 |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
author2_variant |
p t t pt ptt |
hierarchy_parent_title |
Review of scientific instruments |
hierarchy_parent_id |
129509175 |
dewey-tens |
530 - Physics 620 - Engineering |
hierarchy_top_title |
Review of scientific instruments |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)129509175 (DE-600)209865-9 (DE-576)014915782 |
title |
Note: Cryogenic heat switch with stepper motor actuator |
ctrlnum |
(DE-627)OLC196336239X (DE-599)GBVOLC196336239X (PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80 (KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator |
title_full |
Note: Cryogenic heat switch with stepper motor actuator |
author_sort |
Melcher, B S |
journal |
Review of scientific instruments |
journalStr |
Review of scientific instruments |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
500 - Science 600 - Technology |
recordtype |
marc |
publishDateSort |
2015 |
contenttype_str_mv |
txt |
author_browse |
Melcher, B S |
container_volume |
86 |
class |
530 620 DNB |
format_se |
Aufsätze |
author-letter |
Melcher, B S |
dewey-full |
530 620 |
title_sort |
note: cryogenic heat switch with stepper motor actuator |
title_auth |
Note: Cryogenic heat switch with stepper motor actuator |
abstract |
A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. |
abstractGer |
A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. |
abstract_unstemmed |
A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC SSG-OLC-PHY GBV_ILN_21 GBV_ILN_47 GBV_ILN_59 GBV_ILN_70 GBV_ILN_170 GBV_ILN_2219 GBV_ILN_2279 GBV_ILN_4306 GBV_ILN_4310 |
container_issue |
12 |
title_short |
Note: Cryogenic heat switch with stepper motor actuator |
url |
http://www.ncbi.nlm.nih.gov/pubmed/26724093 |
remote_bool |
false |
author2 |
Timbie, P T |
author2Str |
Timbie, P T |
ppnlink |
129509175 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
author2_role |
oth |
up_date |
2024-07-04T05:34:16.926Z |
_version_ |
1803625438294048768 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a2200265 4500</leader><controlfield tag="001">OLC196336239X</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230714160925.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">160206s2015 xx ||||| 00| ||eng c</controlfield><datafield tag="028" ind1="5" ind2="2"><subfield code="a">PQ20160617</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC196336239X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)GBVOLC196336239X</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(PRQ)p478-d6712f27016973c994f75c4c467db65d23f27daddcde1b23251e3e52b38e4fb80</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(KEY)0016010520150000086001200000notecryogenicheatswitchwithsteppermotoractuator</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">530</subfield><subfield code="a">620</subfield><subfield code="q">DNB</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Melcher, B S</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Note: Cryogenic heat switch with stepper motor actuator</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2015</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an "on state" thermal conductance of 5.04 mW/K and no conductance in the "off state." The switch is optimized for cycling an adiabatic demagnetization refrigerator.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Timbie, P T</subfield><subfield code="4">oth</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Review of scientific instruments</subfield><subfield code="d">Melville, NY : AIP, 1930</subfield><subfield code="g">86(2015), 12</subfield><subfield code="w">(DE-627)129509175</subfield><subfield code="w">(DE-600)209865-9</subfield><subfield code="w">(DE-576)014915782</subfield><subfield code="x">0034-6748</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:86</subfield><subfield code="g">year:2015</subfield><subfield code="g">number:12</subfield></datafield><datafield tag="856" ind1="4" ind2="2"><subfield code="u">http://www.ncbi.nlm.nih.gov/pubmed/26724093</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-PHY</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_21</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_47</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_59</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_170</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2219</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2279</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4306</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4310</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">86</subfield><subfield code="j">2015</subfield><subfield code="e">12</subfield></datafield></record></collection>
|
score |
7.401758 |