Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids
Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islandi...
Ausführliche Beschreibung
Autor*in: |
Sanjari, M. J. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2013 |
---|
Schlagwörter: |
---|
Anmerkung: |
© Springer-Verlag London 2013 |
---|
Übergeordnetes Werk: |
Enthalten in: Neural computing & applications - Springer London, 1993, 25(2013), 1 vom: 13. Sept., Seite 189-197 |
---|---|
Übergeordnetes Werk: |
volume:25 ; year:2013 ; number:1 ; day:13 ; month:09 ; pages:189-197 |
Links: |
---|
DOI / URN: |
10.1007/s00521-013-1473-0 |
---|
Katalog-ID: |
OLC2025593767 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2025593767 | ||
003 | DE-627 | ||
005 | 20230502114602.0 | ||
007 | tu | ||
008 | 200820s2013 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.1007/s00521-013-1473-0 |2 doi | |
035 | |a (DE-627)OLC2025593767 | ||
035 | |a (DE-He213)s00521-013-1473-0-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 004 |q VZ |
100 | 1 | |a Sanjari, M. J. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids |
264 | 1 | |c 2013 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
500 | |a © Springer-Verlag London 2013 | ||
520 | |a Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. | ||
650 | 4 | |a Incomplete information | |
650 | 4 | |a Cooperative control | |
650 | 4 | |a Distributed energy resources | |
650 | 4 | |a Decentralized control | |
650 | 4 | |a ANN-based control | |
700 | 1 | |a Gharehpetian, G. B. |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Neural computing & applications |d Springer London, 1993 |g 25(2013), 1 vom: 13. Sept., Seite 189-197 |w (DE-627)165669608 |w (DE-600)1136944-9 |w (DE-576)032873050 |x 0941-0643 |7 nnns |
773 | 1 | 8 | |g volume:25 |g year:2013 |g number:1 |g day:13 |g month:09 |g pages:189-197 |
856 | 4 | 1 | |u https://doi.org/10.1007/s00521-013-1473-0 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-MAT | ||
912 | |a GBV_ILN_70 | ||
912 | |a GBV_ILN_2018 | ||
912 | |a GBV_ILN_4046 | ||
912 | |a GBV_ILN_4277 | ||
951 | |a AR | ||
952 | |d 25 |j 2013 |e 1 |b 13 |c 09 |h 189-197 |
author_variant |
m j s mj mjs g b g gb gbg |
---|---|
matchkey_str |
article:09410643:2013----::nopeenomtobsdeetaiecoeaieotosrtgfritiueeeg |
hierarchy_sort_str |
2013 |
publishDate |
2013 |
allfields |
10.1007/s00521-013-1473-0 doi (DE-627)OLC2025593767 (DE-He213)s00521-013-1473-0-p DE-627 ger DE-627 rakwb eng 004 VZ Sanjari, M. J. verfasserin aut Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids 2013 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag London 2013 Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control Gharehpetian, G. B. aut Enthalten in Neural computing & applications Springer London, 1993 25(2013), 1 vom: 13. Sept., Seite 189-197 (DE-627)165669608 (DE-600)1136944-9 (DE-576)032873050 0941-0643 nnns volume:25 year:2013 number:1 day:13 month:09 pages:189-197 https://doi.org/10.1007/s00521-013-1473-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-MAT GBV_ILN_70 GBV_ILN_2018 GBV_ILN_4046 GBV_ILN_4277 AR 25 2013 1 13 09 189-197 |
spelling |
10.1007/s00521-013-1473-0 doi (DE-627)OLC2025593767 (DE-He213)s00521-013-1473-0-p DE-627 ger DE-627 rakwb eng 004 VZ Sanjari, M. J. verfasserin aut Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids 2013 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag London 2013 Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control Gharehpetian, G. B. aut Enthalten in Neural computing & applications Springer London, 1993 25(2013), 1 vom: 13. Sept., Seite 189-197 (DE-627)165669608 (DE-600)1136944-9 (DE-576)032873050 0941-0643 nnns volume:25 year:2013 number:1 day:13 month:09 pages:189-197 https://doi.org/10.1007/s00521-013-1473-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-MAT GBV_ILN_70 GBV_ILN_2018 GBV_ILN_4046 GBV_ILN_4277 AR 25 2013 1 13 09 189-197 |
allfields_unstemmed |
10.1007/s00521-013-1473-0 doi (DE-627)OLC2025593767 (DE-He213)s00521-013-1473-0-p DE-627 ger DE-627 rakwb eng 004 VZ Sanjari, M. J. verfasserin aut Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids 2013 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag London 2013 Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control Gharehpetian, G. B. aut Enthalten in Neural computing & applications Springer London, 1993 25(2013), 1 vom: 13. Sept., Seite 189-197 (DE-627)165669608 (DE-600)1136944-9 (DE-576)032873050 0941-0643 nnns volume:25 year:2013 number:1 day:13 month:09 pages:189-197 https://doi.org/10.1007/s00521-013-1473-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-MAT GBV_ILN_70 GBV_ILN_2018 GBV_ILN_4046 GBV_ILN_4277 AR 25 2013 1 13 09 189-197 |
allfieldsGer |
10.1007/s00521-013-1473-0 doi (DE-627)OLC2025593767 (DE-He213)s00521-013-1473-0-p DE-627 ger DE-627 rakwb eng 004 VZ Sanjari, M. J. verfasserin aut Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids 2013 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag London 2013 Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control Gharehpetian, G. B. aut Enthalten in Neural computing & applications Springer London, 1993 25(2013), 1 vom: 13. Sept., Seite 189-197 (DE-627)165669608 (DE-600)1136944-9 (DE-576)032873050 0941-0643 nnns volume:25 year:2013 number:1 day:13 month:09 pages:189-197 https://doi.org/10.1007/s00521-013-1473-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-MAT GBV_ILN_70 GBV_ILN_2018 GBV_ILN_4046 GBV_ILN_4277 AR 25 2013 1 13 09 189-197 |
allfieldsSound |
10.1007/s00521-013-1473-0 doi (DE-627)OLC2025593767 (DE-He213)s00521-013-1473-0-p DE-627 ger DE-627 rakwb eng 004 VZ Sanjari, M. J. verfasserin aut Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids 2013 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier © Springer-Verlag London 2013 Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control Gharehpetian, G. B. aut Enthalten in Neural computing & applications Springer London, 1993 25(2013), 1 vom: 13. Sept., Seite 189-197 (DE-627)165669608 (DE-600)1136944-9 (DE-576)032873050 0941-0643 nnns volume:25 year:2013 number:1 day:13 month:09 pages:189-197 https://doi.org/10.1007/s00521-013-1473-0 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-MAT GBV_ILN_70 GBV_ILN_2018 GBV_ILN_4046 GBV_ILN_4277 AR 25 2013 1 13 09 189-197 |
language |
English |
source |
Enthalten in Neural computing & applications 25(2013), 1 vom: 13. Sept., Seite 189-197 volume:25 year:2013 number:1 day:13 month:09 pages:189-197 |
sourceStr |
Enthalten in Neural computing & applications 25(2013), 1 vom: 13. Sept., Seite 189-197 volume:25 year:2013 number:1 day:13 month:09 pages:189-197 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
topic_facet |
Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control |
dewey-raw |
004 |
isfreeaccess_bool |
false |
container_title |
Neural computing & applications |
authorswithroles_txt_mv |
Sanjari, M. J. @@aut@@ Gharehpetian, G. B. @@aut@@ |
publishDateDaySort_date |
2013-09-13T00:00:00Z |
hierarchy_top_id |
165669608 |
dewey-sort |
14 |
id |
OLC2025593767 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2025593767</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230502114602.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s2013 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00521-013-1473-0</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2025593767</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s00521-013-1473-0-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">004</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Sanjari, M. J.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2013</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag London 2013</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Incomplete information</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cooperative control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Distributed energy resources</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Decentralized control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">ANN-based control</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gharehpetian, G. B.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Neural computing & applications</subfield><subfield code="d">Springer London, 1993</subfield><subfield code="g">25(2013), 1 vom: 13. Sept., Seite 189-197</subfield><subfield code="w">(DE-627)165669608</subfield><subfield code="w">(DE-600)1136944-9</subfield><subfield code="w">(DE-576)032873050</subfield><subfield code="x">0941-0643</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:25</subfield><subfield code="g">year:2013</subfield><subfield code="g">number:1</subfield><subfield code="g">day:13</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:189-197</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s00521-013-1473-0</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-MAT</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2018</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4277</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">25</subfield><subfield code="j">2013</subfield><subfield code="e">1</subfield><subfield code="b">13</subfield><subfield code="c">09</subfield><subfield code="h">189-197</subfield></datafield></record></collection>
|
author |
Sanjari, M. J. |
spellingShingle |
Sanjari, M. J. ddc 004 misc Incomplete information misc Cooperative control misc Distributed energy resources misc Decentralized control misc ANN-based control Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids |
authorStr |
Sanjari, M. J. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)165669608 |
format |
Article |
dewey-ones |
004 - Data processing & computer science |
delete_txt_mv |
keep |
author_role |
aut aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
0941-0643 |
topic_title |
004 VZ Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids Incomplete information Cooperative control Distributed energy resources Decentralized control ANN-based control |
topic |
ddc 004 misc Incomplete information misc Cooperative control misc Distributed energy resources misc Decentralized control misc ANN-based control |
topic_unstemmed |
ddc 004 misc Incomplete information misc Cooperative control misc Distributed energy resources misc Decentralized control misc ANN-based control |
topic_browse |
ddc 004 misc Incomplete information misc Cooperative control misc Distributed energy resources misc Decentralized control misc ANN-based control |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Neural computing & applications |
hierarchy_parent_id |
165669608 |
dewey-tens |
000 - Computer science, knowledge & systems |
hierarchy_top_title |
Neural computing & applications |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)165669608 (DE-600)1136944-9 (DE-576)032873050 |
title |
Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids |
ctrlnum |
(DE-627)OLC2025593767 (DE-He213)s00521-013-1473-0-p |
title_full |
Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids |
author_sort |
Sanjari, M. J. |
journal |
Neural computing & applications |
journalStr |
Neural computing & applications |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
000 - Computer science, information & general works |
recordtype |
marc |
publishDateSort |
2013 |
contenttype_str_mv |
txt |
container_start_page |
189 |
author_browse |
Sanjari, M. J. Gharehpetian, G. B. |
container_volume |
25 |
class |
004 VZ |
format_se |
Aufsätze |
author-letter |
Sanjari, M. J. |
doi_str_mv |
10.1007/s00521-013-1473-0 |
dewey-full |
004 |
title_sort |
incomplete information-based decentralized cooperative control strategy for distributed energy resources of vsi-based microgrids |
title_auth |
Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids |
abstract |
Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. © Springer-Verlag London 2013 |
abstractGer |
Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. © Springer-Verlag London 2013 |
abstract_unstemmed |
Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods. © Springer-Verlag London 2013 |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-MAT GBV_ILN_70 GBV_ILN_2018 GBV_ILN_4046 GBV_ILN_4277 |
container_issue |
1 |
title_short |
Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids |
url |
https://doi.org/10.1007/s00521-013-1473-0 |
remote_bool |
false |
author2 |
Gharehpetian, G. B. |
author2Str |
Gharehpetian, G. B. |
ppnlink |
165669608 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.1007/s00521-013-1473-0 |
up_date |
2024-07-04T01:38:44.071Z |
_version_ |
1803610618931970048 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2025593767</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20230502114602.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200820s2013 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.1007/s00521-013-1473-0</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2025593767</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)s00521-013-1473-0-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">004</subfield><subfield code="q">VZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Sanjari, M. J.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Incomplete information-based decentralized cooperative control strategy for distributed energy resources of VSI-based microgrids</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2013</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">© Springer-Verlag London 2013</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract This paper presents an effective method to control distributed energy resources (DERs) installed in a microgrid (MG) to guarantee its stability after islanding occurrence. Considering voltage and frequency variations after islanding occurrence and based on stability criteria, MG pre-islanding conditions are divided into secure and insecure classes. It is shown that insecure MG can become secure, if appropriate preventive control is applied on the DERs in different operating conditions of the MG. To select the most important variables of MG, which can estimate proper values of output power set points of DERs, a feature selection procedure known as symmetrical uncertainty is used in this paper. Among all the MG variables, critical ones are selected to calculate the appropriate output power of different DERs for different conditions of the MG. The values of selected features are transmitted by the communication system to the control unit installed on each DER to control its output power set point. In order to decrease the communication system cost, previous researchers have used local variables to control the set point of different DERs. This approach decreases the accuracy of the controller because the controller uses incomplete information. In this paper, multi-objective approach is used in order to decrease the cost of the communication system, while keeping the accuracy of the preventive control strategy in an allowable margin. The results demonstrate the effectiveness of the proposed method in comparison with other methods.</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Incomplete information</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Cooperative control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Distributed energy resources</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">Decentralized control</subfield></datafield><datafield tag="650" ind1=" " ind2="4"><subfield code="a">ANN-based control</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Gharehpetian, G. B.</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Neural computing & applications</subfield><subfield code="d">Springer London, 1993</subfield><subfield code="g">25(2013), 1 vom: 13. Sept., Seite 189-197</subfield><subfield code="w">(DE-627)165669608</subfield><subfield code="w">(DE-600)1136944-9</subfield><subfield code="w">(DE-576)032873050</subfield><subfield code="x">0941-0643</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:25</subfield><subfield code="g">year:2013</subfield><subfield code="g">number:1</subfield><subfield code="g">day:13</subfield><subfield code="g">month:09</subfield><subfield code="g">pages:189-197</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.1007/s00521-013-1473-0</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-MAT</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_2018</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4046</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_4277</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">25</subfield><subfield code="j">2013</subfield><subfield code="e">1</subfield><subfield code="b">13</subfield><subfield code="c">09</subfield><subfield code="h">189-197</subfield></datafield></record></collection>
|
score |
7.3974915 |