Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement
Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the mater...
Ausführliche Beschreibung
Autor*in: |
Trofimov, V. N. [verfasserIn] Karmanov, V. V. [verfasserIn] Shiryaev, A. A. [verfasserIn] Zvonov, S. N. [verfasserIn] |
---|
Format: |
Artikel |
---|---|
Sprache: |
Englisch |
Erschienen: |
2019 |
---|
Übergeordnetes Werk: |
Enthalten in: Russian engineering research - New York, NY : Allerton Press, 1992, 39(2019), 3 vom: März, Seite 276-278 |
---|---|
Übergeordnetes Werk: |
volume:39 ; year:2019 ; number:3 ; month:03 ; pages:276-278 |
Links: |
---|
DOI / URN: |
10.3103/S1068798X19030225 |
---|
Katalog-ID: |
OLC2029412481 |
---|
LEADER | 01000caa a22002652 4500 | ||
---|---|---|---|
001 | OLC2029412481 | ||
003 | DE-627 | ||
005 | 20220909103438.0 | ||
007 | tu | ||
008 | 200819s2019 xx ||||| 00| ||eng c | ||
024 | 7 | |a 10.3103/S1068798X19030225 |2 doi | |
035 | |a (DE-627)OLC2029412481 | ||
035 | |a (DE-He213)S1068798X19030225-p | ||
040 | |a DE-627 |b ger |c DE-627 |e rakwb | ||
041 | |a eng | ||
082 | 0 | 4 | |a 620 |q AVZ |
100 | 1 | |a Trofimov, V. N. |e verfasserin |4 aut | |
245 | 1 | 0 | |a Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
264 | 1 | |c 2019 | |
336 | |a Text |b txt |2 rdacontent | ||
337 | |a ohne Hilfsmittel zu benutzen |b n |2 rdamedia | ||
338 | |a Band |b nc |2 rdacarrier | ||
520 | |a Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. | ||
700 | 1 | |a Karmanov, V. V. |e verfasserin |4 aut | |
700 | 1 | |a Shiryaev, A. A. |e verfasserin |4 aut | |
700 | 1 | |a Zvonov, S. N. |e verfasserin |4 aut | |
773 | 0 | 8 | |i Enthalten in |t Russian engineering research |d New York, NY : Allerton Press, 1992 |g 39(2019), 3 vom: März, Seite 276-278 |w (DE-627)131162225 |w (DE-600)1134841-0 |w (DE-576)032869150 |x 1068-798X |7 nnns |
773 | 1 | 8 | |g volume:39 |g year:2019 |g number:3 |g month:03 |g pages:276-278 |
856 | 4 | 1 | |u https://doi.org/10.3103/S1068798X19030225 |z lizenzpflichtig |3 Volltext |
912 | |a GBV_USEFLAG_A | ||
912 | |a SYSFLAG_A | ||
912 | |a GBV_OLC | ||
912 | |a SSG-OLC-TEC | ||
912 | |a GBV_ILN_70 | ||
951 | |a AR | ||
952 | |d 39 |j 2019 |e 3 |c 03 |h 276-278 |
author_variant |
v n t vn vnt v v k vv vvk a a s aa aas s n z sn snz |
---|---|
matchkey_str |
article:1068798X:2019----::airtooxadfrcinntuetfreiu |
hierarchy_sort_str |
2019 |
publishDate |
2019 |
allfields |
10.3103/S1068798X19030225 doi (DE-627)OLC2029412481 (DE-He213)S1068798X19030225-p DE-627 ger DE-627 rakwb eng 620 AVZ Trofimov, V. N. verfasserin aut Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement 2019 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. Karmanov, V. V. verfasserin aut Shiryaev, A. A. verfasserin aut Zvonov, S. N. verfasserin aut Enthalten in Russian engineering research New York, NY : Allerton Press, 1992 39(2019), 3 vom: März, Seite 276-278 (DE-627)131162225 (DE-600)1134841-0 (DE-576)032869150 1068-798X nnns volume:39 year:2019 number:3 month:03 pages:276-278 https://doi.org/10.3103/S1068798X19030225 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_70 AR 39 2019 3 03 276-278 |
spelling |
10.3103/S1068798X19030225 doi (DE-627)OLC2029412481 (DE-He213)S1068798X19030225-p DE-627 ger DE-627 rakwb eng 620 AVZ Trofimov, V. N. verfasserin aut Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement 2019 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. Karmanov, V. V. verfasserin aut Shiryaev, A. A. verfasserin aut Zvonov, S. N. verfasserin aut Enthalten in Russian engineering research New York, NY : Allerton Press, 1992 39(2019), 3 vom: März, Seite 276-278 (DE-627)131162225 (DE-600)1134841-0 (DE-576)032869150 1068-798X nnns volume:39 year:2019 number:3 month:03 pages:276-278 https://doi.org/10.3103/S1068798X19030225 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_70 AR 39 2019 3 03 276-278 |
allfields_unstemmed |
10.3103/S1068798X19030225 doi (DE-627)OLC2029412481 (DE-He213)S1068798X19030225-p DE-627 ger DE-627 rakwb eng 620 AVZ Trofimov, V. N. verfasserin aut Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement 2019 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. Karmanov, V. V. verfasserin aut Shiryaev, A. A. verfasserin aut Zvonov, S. N. verfasserin aut Enthalten in Russian engineering research New York, NY : Allerton Press, 1992 39(2019), 3 vom: März, Seite 276-278 (DE-627)131162225 (DE-600)1134841-0 (DE-576)032869150 1068-798X nnns volume:39 year:2019 number:3 month:03 pages:276-278 https://doi.org/10.3103/S1068798X19030225 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_70 AR 39 2019 3 03 276-278 |
allfieldsGer |
10.3103/S1068798X19030225 doi (DE-627)OLC2029412481 (DE-He213)S1068798X19030225-p DE-627 ger DE-627 rakwb eng 620 AVZ Trofimov, V. N. verfasserin aut Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement 2019 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. Karmanov, V. V. verfasserin aut Shiryaev, A. A. verfasserin aut Zvonov, S. N. verfasserin aut Enthalten in Russian engineering research New York, NY : Allerton Press, 1992 39(2019), 3 vom: März, Seite 276-278 (DE-627)131162225 (DE-600)1134841-0 (DE-576)032869150 1068-798X nnns volume:39 year:2019 number:3 month:03 pages:276-278 https://doi.org/10.3103/S1068798X19030225 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_70 AR 39 2019 3 03 276-278 |
allfieldsSound |
10.3103/S1068798X19030225 doi (DE-627)OLC2029412481 (DE-He213)S1068798X19030225-p DE-627 ger DE-627 rakwb eng 620 AVZ Trofimov, V. N. verfasserin aut Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement 2019 Text txt rdacontent ohne Hilfsmittel zu benutzen n rdamedia Band nc rdacarrier Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. Karmanov, V. V. verfasserin aut Shiryaev, A. A. verfasserin aut Zvonov, S. N. verfasserin aut Enthalten in Russian engineering research New York, NY : Allerton Press, 1992 39(2019), 3 vom: März, Seite 276-278 (DE-627)131162225 (DE-600)1134841-0 (DE-576)032869150 1068-798X nnns volume:39 year:2019 number:3 month:03 pages:276-278 https://doi.org/10.3103/S1068798X19030225 lizenzpflichtig Volltext GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_70 AR 39 2019 3 03 276-278 |
language |
English |
source |
Enthalten in Russian engineering research 39(2019), 3 vom: März, Seite 276-278 volume:39 year:2019 number:3 month:03 pages:276-278 |
sourceStr |
Enthalten in Russian engineering research 39(2019), 3 vom: März, Seite 276-278 volume:39 year:2019 number:3 month:03 pages:276-278 |
format_phy_str_mv |
Article |
institution |
findex.gbv.de |
dewey-raw |
620 |
isfreeaccess_bool |
false |
container_title |
Russian engineering research |
authorswithroles_txt_mv |
Trofimov, V. N. @@aut@@ Karmanov, V. V. @@aut@@ Shiryaev, A. A. @@aut@@ Zvonov, S. N. @@aut@@ |
publishDateDaySort_date |
2019-03-01T00:00:00Z |
hierarchy_top_id |
131162225 |
dewey-sort |
3620 |
id |
OLC2029412481 |
language_de |
englisch |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2029412481</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20220909103438.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2019 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3103/S1068798X19030225</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2029412481</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)S1068798X19030225-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">620</subfield><subfield code="q">AVZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Trofimov, V. N.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Karmanov, V. V.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Shiryaev, A. A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zvonov, S. N.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Russian engineering research</subfield><subfield code="d">New York, NY : Allerton Press, 1992</subfield><subfield code="g">39(2019), 3 vom: März, Seite 276-278</subfield><subfield code="w">(DE-627)131162225</subfield><subfield code="w">(DE-600)1134841-0</subfield><subfield code="w">(DE-576)032869150</subfield><subfield code="x">1068-798X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:39</subfield><subfield code="g">year:2019</subfield><subfield code="g">number:3</subfield><subfield code="g">month:03</subfield><subfield code="g">pages:276-278</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.3103/S1068798X19030225</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">39</subfield><subfield code="j">2019</subfield><subfield code="e">3</subfield><subfield code="c">03</subfield><subfield code="h">276-278</subfield></datafield></record></collection>
|
author |
Trofimov, V. N. |
spellingShingle |
Trofimov, V. N. ddc 620 Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
authorStr |
Trofimov, V. N. |
ppnlink_with_tag_str_mv |
@@773@@(DE-627)131162225 |
format |
Article |
dewey-ones |
620 - Engineering & allied operations |
delete_txt_mv |
keep |
author_role |
aut aut aut aut |
collection |
OLC |
remote_str |
false |
illustrated |
Not Illustrated |
issn |
1068-798X |
topic_title |
620 AVZ Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
topic |
ddc 620 |
topic_unstemmed |
ddc 620 |
topic_browse |
ddc 620 |
format_facet |
Aufsätze Gedruckte Aufsätze |
format_main_str_mv |
Text Zeitschrift/Artikel |
carriertype_str_mv |
nc |
hierarchy_parent_title |
Russian engineering research |
hierarchy_parent_id |
131162225 |
dewey-tens |
620 - Engineering |
hierarchy_top_title |
Russian engineering research |
isfreeaccess_txt |
false |
familylinks_str_mv |
(DE-627)131162225 (DE-600)1134841-0 (DE-576)032869150 |
title |
Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
ctrlnum |
(DE-627)OLC2029412481 (DE-He213)S1068798X19030225-p |
title_full |
Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
author_sort |
Trofimov, V. N. |
journal |
Russian engineering research |
journalStr |
Russian engineering research |
lang_code |
eng |
isOA_bool |
false |
dewey-hundreds |
600 - Technology |
recordtype |
marc |
publishDateSort |
2019 |
contenttype_str_mv |
txt |
container_start_page |
276 |
author_browse |
Trofimov, V. N. Karmanov, V. V. Shiryaev, A. A. Zvonov, S. N. |
container_volume |
39 |
class |
620 AVZ |
format_se |
Aufsätze |
author-letter |
Trofimov, V. N. |
doi_str_mv |
10.3103/S1068798X19030225 |
dewey-full |
620 |
author2-role |
verfasserin |
title_sort |
calibration of x-ray diffraction instruments for residual-stress measurement |
title_auth |
Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
abstract |
Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. |
abstractGer |
Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. |
abstract_unstemmed |
Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration. |
collection_details |
GBV_USEFLAG_A SYSFLAG_A GBV_OLC SSG-OLC-TEC GBV_ILN_70 |
container_issue |
3 |
title_short |
Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement |
url |
https://doi.org/10.3103/S1068798X19030225 |
remote_bool |
false |
author2 |
Karmanov, V. V. Shiryaev, A. A. Zvonov, S. N. |
author2Str |
Karmanov, V. V. Shiryaev, A. A. Zvonov, S. N. |
ppnlink |
131162225 |
mediatype_str_mv |
n |
isOA_txt |
false |
hochschulschrift_bool |
false |
doi_str |
10.3103/S1068798X19030225 |
up_date |
2024-07-03T22:46:00.399Z |
_version_ |
1803599751833190400 |
fullrecord_marcxml |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01000caa a22002652 4500</leader><controlfield tag="001">OLC2029412481</controlfield><controlfield tag="003">DE-627</controlfield><controlfield tag="005">20220909103438.0</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">200819s2019 xx ||||| 00| ||eng c</controlfield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">10.3103/S1068798X19030225</subfield><subfield code="2">doi</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-627)OLC2029412481</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-He213)S1068798X19030225-p</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">DE-627</subfield><subfield code="b">ger</subfield><subfield code="c">DE-627</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="082" ind1="0" ind2="4"><subfield code="a">620</subfield><subfield code="q">AVZ</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Trofimov, V. N.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2019</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">Text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">ohne Hilfsmittel zu benutzen</subfield><subfield code="b">n</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">Band</subfield><subfield code="b">nc</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">Abstract The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration.</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Karmanov, V. V.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Shiryaev, A. A.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="700" ind1="1" ind2=" "><subfield code="a">Zvonov, S. N.</subfield><subfield code="e">verfasserin</subfield><subfield code="4">aut</subfield></datafield><datafield tag="773" ind1="0" ind2="8"><subfield code="i">Enthalten in</subfield><subfield code="t">Russian engineering research</subfield><subfield code="d">New York, NY : Allerton Press, 1992</subfield><subfield code="g">39(2019), 3 vom: März, Seite 276-278</subfield><subfield code="w">(DE-627)131162225</subfield><subfield code="w">(DE-600)1134841-0</subfield><subfield code="w">(DE-576)032869150</subfield><subfield code="x">1068-798X</subfield><subfield code="7">nnns</subfield></datafield><datafield tag="773" ind1="1" ind2="8"><subfield code="g">volume:39</subfield><subfield code="g">year:2019</subfield><subfield code="g">number:3</subfield><subfield code="g">month:03</subfield><subfield code="g">pages:276-278</subfield></datafield><datafield tag="856" ind1="4" ind2="1"><subfield code="u">https://doi.org/10.3103/S1068798X19030225</subfield><subfield code="z">lizenzpflichtig</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_USEFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SYSFLAG_A</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_OLC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">SSG-OLC-TEC</subfield></datafield><datafield tag="912" ind1=" " ind2=" "><subfield code="a">GBV_ILN_70</subfield></datafield><datafield tag="951" ind1=" " ind2=" "><subfield code="a">AR</subfield></datafield><datafield tag="952" ind1=" " ind2=" "><subfield code="d">39</subfield><subfield code="j">2019</subfield><subfield code="e">3</subfield><subfield code="c">03</subfield><subfield code="h">276-278</subfield></datafield></record></collection>
|
score |
7.397993 |